materi pelatihan alarm & pemercik

19
1 SISTEM ALARM & PEMERCIK

Upload: eko-kiswanto

Post on 03-Jul-2015

2.771 views

Category:

Documents


10 download

TRANSCRIPT

11

SISTEM ALARM & PEMERCIK

SISTEM ALARM KEBAKARAN

SISTEM ALARM KEBAKARAN ADALAH SISTEM INSTALASI ELEKTRONIK YANG BERFUNGSI UNTUK MEMBERITAHU ADANYA SUMBER GEJALA API KEBAKARAN SEDINI MUNGKIN SEJAK SAAT-SAAT AWAL GEJALA ITU MUNCUL

INFORMASI ADANYA SUMBER API BISA DINYATAKAN DALAM BENTUK ZONE AREA KEBAKARAN MELIPUTI LUASAN TERTENTU, ATAU DINYATAKAN DALAM TITIK (POINT) KEBAKARAN YANG MELIPUTI RUANGAN TERTENTU

INFORMASI LOKASI KEBAKARAN DIKIRIM DALAM BENTUK SINYAL LISTRIK INPUT DARI SUMBER API KE SENTRAL KONTROL DI RUANGAN KONTROL MELALUI KABEL YANG SETELAH DIPROSES SECARA ELEKTRONIK AKAN MENGHASILKAN SINYAL LISTRIK OUTPUT YANG AKAN MEMBUNYIKAN ALARM BELL DAN MENYALAKAN SAKLAR LISTRIK

PERANGKAT SISTEM ALARM

1. DETECTOR Terdapat beberapa jenis DETECTOR tergantung gejalaKebakaran yang

dideteksinya : SMOKE DETECTOR Alat ini bekerja apabila Ion asap memasuki ruang deteksi radio aktif sehingga terjadi perubahan perbandingan partikel Ion + (positif) dan Ion

negatif yang mengakibatkan rangkaian electrik contactmenjadi aktif. Biasanya alat ini digunakan apabila dibutuhkan deteksi seawal mungkin

untuk suatu ruangan seperti ruang computer,arsip,akan tetapi ruangan tersebut tidak diperkenankan merokok.

HEAT DETECTORHEAT DETECTOR

Alat ini bekerja apabila panas yang masuk pada ruang deteksi naik 7-10 derajat perdetik sehingga perbedaan panas kedua ruangan deteksi berbeda yang m,rngakibatkan mechanikal contactmenjadi aktif

Biasanya alat ini digunakan sebagai,alat deteksi panas biasa untuk ruangan2 kantor , hotel , pusat perbelanjaan.

55

FLAME DETECTORFLAME DETECTOR

Alat ini bekerja apabila terdapat api sehingga sinar ultra violet yang dipancarkan dapat ditangkap oleh deteksi ultra violet mengakibatkan rangkaian electronik – contact menjadi aktif

Alat ini digunakan untuk deteksi ruangan yang agak besar / tinggi atau ruangan yang menyimpan barang2yang mudah terbakar seperti gudang mesiu, minyak, bahan kimia.

1. MASTER CONTROL PANEL FIRE ALARM (MCFA)ADA 2 (dua) JENIS MCPFA

A. CONVENTIONAL SYSTEM

UNTUK MENUNJUKKAN LOKASI KEBAKARAN, MAKA RUANGAN-RUANGAN PADA SATU LANTAI DIBAGI KEPADA BEBERAPA ZONE AREA KEBAKARAN. PEMBAGIAN ZONE INI UNTUK MEMUDAHKAN INFORMASI BAGI PETUGAS PEMADAM AGAR BERGERAK CEPAT DAN EFFEKTIF MENUJU SUMBER API, UNTUK PENGECEKAN DAN PENANGGULANGAN KEBAKARAN, PENENTUAN ZONE INI DISESUAIKAN DENGAN LOKASI TANGGA KEBAKARAN, MISSAL : ZONE 20 T = LANTAI 20 AREA TIMUR. PENENTUAN AREA 1 ZONE DITENTUKAN JUGA OLEH JUMLAH DETECTOR DALAM ZONE TERSEBUT.

A. ADDRESSABLE SYSTEM

UNTUK INFORMASI LOKASI API YANG LEBIH AKURAT DIGUNAKAN SISTEM ALAMAT TITIK API (ADDRESS POINT), DIMANA INFORMASI SUMBER KEBAKARAN BERUPA TITIK LOKASI YANG LEBIH JELAS DAN PASTI, MISALNYA RUANG FOTO COPY, RUANG PANEL LISTRIK.

1. MAIN CONTROL UNIT (Central Processing Unit)2. INPUT/OUTPUT MODULE3. INDICATOR LAMPS & DISPLAY4. OUTPUT BUZZER / SOUNDER / AUDIBLE DEVICE5. SWTICTH & BUTTON FOR CONTROL, TEST & RESET6. POWER SUPPLY UNIT & BATTERY CHARGER7. INTERFACE KE ANNUNCIATOR, PC DAN PRINTER

PROGRAM (SOFTWARE) YANG DIKERJAKAN OLEH MCPFA ADALAH :

PERANGKAT KERAS YANG ADA DIDALAM MCFA ADALAH :

1. MEMONITOR DETEKSI SUMBER KEBAKARAN2. MEMBERI INFORMASI MENGENAI LOKASI SUMBER KEBAKARAN3. SECARA OTOMATIS MELAKUKAN ANNOUNCEMENT, EVAKUASI

DAN TINDAKAN PENGENDALIAN DALAM RANGKA PENANGGULANGAN KEBAKARAN MELALUI PERALATAN-PERALATAN MEKANIKAL & ELEKTRIKAL YANG SUDAH DISIAPKAN.

4. MEREKAM DATA INFORMASI KEBAKARAN5. MENYEDIAKAN SARANA MANUAL UNTUK PENGENDALIAN

BERUPA MMI (man to Mchine Interface)

ALARM BELL BERFUNGSI UNTUK MEMBERIKAN PERINGATAN DINI BAGI SELURUH PENGHUNI GEDUNG KARENA ITU DIPERLUKAN UKURAN FISIK DAN KEKUATAN SUARA YANG MEMADAI UNTUK MEMENUHI FUNGSI TERSEBUT.

BEKERJA DENGAN 24 VDC DARI SENTRALDALAM MENILAI MUTU ALARM BELL DIPERHATIKAN MENGENAI ALARM CURRENT (mA) DAN SOUND PRESSURE LEVEL (SPL) DALAM Db/1 m.PATUT DIPERHATIKAN BAHWA PARTISI RUANGAN BAIK KAYU, BATA NAUPUN BETON AKAN MENGAKIBATKAN REDAMAN TERTENTU PADA LEVEL SUARA BELL.

1. ALARM BELL

UKURAN FISIK UMUMNYA BERDIAMETER 6 INCH. KEKUATAN SUARA (SOUND PRESSURE LEVEL = SPL) SEKITAR 87 Db/1 m SAMPAI 90 Db/1m

ALARM LAMP DITEMPATKAN DI AREA PUBLIC ATAU ESCAPE ROUTE DEKAT MANUAL ALARM. BERGUNA UNTUK MENUNJUKKAN LOKASI MANUAL ALARM SEKALIGUS MEMBIMBING KEARAH JALAN YANG AMAN PADA SAAT EVAKUASI.BEKERJA DENGAN TEGANGAN 24 VAD/VDC – 21 mA DARI SENTRAL

CONTACTOR LISTRIK BERADA PADA PANEL LISTRIK PERALATAN MEKANIKAL & ELEKTRIKAL YANG ADA HUBUNGANNYA DENGAN KEBAKARAN. DIGUNAKAN UNTUK MENERIMA SINYAL PENGENALIDAN DARI SENTRAL FIRE ALARM, BAIK UNTUK ON MAUPUN OFF.

1. ALARM LAMP

1. CONTACTOR

MERUPAKAN PANEL LAMPU YANG DIPASANG DI DINDING, YANG MUDAH DILIHAT DARI PINTU RUANG PUSAT KENDALI KEBAKARAN. BERISI INFORMASI MENGENAI ZONE AREA KEBAKARAN DAN AKTIFITAS PERALATAN M & E YANG IKUT BERPERAN DALAM PENANGGULANGAN KEBAKARAN.PANEL DILENGKAPI DENGAN ALARM LAMP, BUZZER, TEST BUTTON DAN SILENCER/RESET BUTTON. HUBUNGAN ANTARA MIMIC PANEL DENGAN MCPFA MELALUI KABEL DATA.UKURAN SEKITAR 80 cm x 120 cm ATAU DISESUAIKAN DENGAN KEBUTUHAN.

1. MIMIC PANEL

ADANYA GEJALA SUMBER BAHAYA KEBAKARAN BISA MUNCUL DALAM BEBERAPA INDIKASI : SUHU YANG TINGGI, KENAIKAN SUHU YANG CEPAT, ADANYA ASAP, ADANYA BUNGA API (PERCIK), ADA KEBOCORAN GAS, GETARAN GEMPA BUMI DAN KEBOCORAN LISTRIK.

PRINSIP KERJA ALARM KEBAKARAN

1. SUHU

KEADAAN RAWAN SEBAGAI SUMBER BAHAYA KEBAKARAN BERDASARKAN INDIKASI SUHU ADALAH :

a. SUHU RUANGAN MENCAPAI 520 C – 57o C/MENIT UNTUK FIXED TEMPERATURE

b. KENAIKAN SUHU DENGAN KECEPATAN 10o C /MENIT UNTUK RATE OF RISE

1. ASAP

KEADAAN RAWAN SEBAGAI SUMBER BAHAYA KEBAKARAN BERDASARKAN INDIKASI ASAP ADALAH MUNCUL DAN NAIKNYA ASAP YANG MENYEBABKAN LEVEL CAHAYA RUANGAN MENURUN SEBESAR 0,1 – 0,3 % ft LIGHT OBSCURATION (PENGABURAN CAHAYA)

1. BUNGA API

KEADAAN RAWAN SEBAGAI INDIKASI SUMBER BAHAYA KEBAKARAN ADALAH TERLIHAT ADANYA BUNGA API ATAU PERCIK API YANG UMUMNYA MEMANCARKAN SINAR INFRA MERAH.

1. MANUAL ALARM POINT

PERANGKAT INI BERUPA SWITCH YANG MENJADI ON BILA DITEKAN OLEH SESEORANG YANG INGIN MEMBERITAHU LANGSUNG KE SENTRAL, BAHWA ADA BAHAYA API KEBAKARAN DI AREA SEKITAR MANUAL ALARM POINT.

MANUAL ALARM POINT TERDIRI DARI :A. TARIKB. TEKANC. TEKAN - TARIK

SPRINKLERSPRINKLER

Adalah suatu sistim instalasi pemadam kebakaran yang dipasang secara tetap/permanen didalam bangunan yang dapat memadamkan kebakaran secara otomatisdengan menyemprotkan air ditempat mulai terjadi kebakaran.

1. Kepadatan Pancaran Jumlah debit air ( liter/menit ) yang dikeluarkan oleh 4 kepala splingkler yang berdekatan dan terletak di empat sudut bujur sangkar 2. Penyedian air. Volume air - Bahaya kebakaran ringan : minimal masa pakai 45 menit - Bahaya kebakaran sedang ; minimal masa pakai 60 menit - Bahaya kebakaran berat ; minimal masa pakai 90 menit

- Sumber air- Sumber air

Air dari sumur pompa atau dari perusahaan air minum dengan kualitas air bersih.

3. Pompa Sprinkler - mampu mensuplai air dalam kapasitas besar, daya dorong cukup

tinggi - Karakteristik dan kinerja pompa paling cocok untuk pompa kebakaran 4. Motor penggerak - motor listrik - motor diesel 5. Panel pompa harus dapat mengalihkan arus listrik konstant kepompa dengan pengaturan start otomatis dengan stop manual.

6. Penyedian pompa6. Penyedian pompa - pompa pembantu ( jocky pump )

- pompa utama

- pompa cadangan

7. Ruang pompa

- mudah dicapai

- ruang gerak bebas sehingga mudah melakukan

perbaikan,pemeliharaan

- nyaman

- tidak banjir

- bebas dari barang yang mudah terbakar

- bebas dari penempatan barang lainnya.

7. Kapasitas pompa7. Kapasitas pompa

- kemampuan pompa untuk mensuplai volume air

- kemampuan pompa untuk mendorong volume air

- kemampuan untuk menghisap air dari permukaan sampai ke

poros pompa

Tersendiri disesuaikan dengan klasipikasi sprinkler Gabungan dengan hidran

8. Pemipaan Bahan Pipa: disesuaikan dengan perhitungan hidrolik atau skedul pipa

- pipa tembaga

- black steel

- Galvanized

- Besi tuang dengan flaus

- besi tuang dengan mot

Jenis Pipa

- Pipa hisap - Pipa Pembagi

- Pipa Utama - Pipa Cabang

- Pipa Tegak

- Pipa Pembagi Utama

Kapasitas pompa untuk sprinklerKapasitas pompa untuk sprinkler

Terima KasihTerima Kasih