anliso setting

7
CARA SETING PARAMETER DOOR OPERATOR ANLISO LOUSER LIFT RND ELEKTRIK I. LANGKAH AWAL SETING PARAMETER 1. POSISIKAN KERETA LIFT DI PERTENGAHAN LANTAI AGAR PINTU KERETA DAPAT DIKALIBRASI ( INSPECTION MODE ). 2. ATUR JARAK BESI SENSOR + 2 mm DENGAN SENSOR NBDZ (pojok kanan atas pada hanger door motor). 3. ATUR DOOR LOCK PADA CAM DOOR MOTOR DENGAN KEMIRINGAN – 2 mm DAN LOCK HOOK HARUS SALING BERSENTUHAN ADAPUN MAKSIMUM KERENGGANGAN 1 mm TIDAK BOLEH LEBIH. 4. PADA SAAT SET DOOR LOCK PINTU KERETA HARUS BENAR-BENAR TERTUTUP RAPAT TIDAK BOLEH BERGERAK DAN CAM DALAM POSISI TERBUKA. 5. PASTIKAN CAM DOOR MOTOR TIDAK MIRING. GB.1 CAM DOOR MOTOR ALINSO

Upload: jay

Post on 13-Apr-2018

443 views

Category:

Documents


60 download

TRANSCRIPT

Page 1: ANLISO Setting

7/21/2019 ANLISO Setting

http://slidepdf.com/reader/full/anliso-setting 1/7

CARA SETING PARAMETER DOOR OPERATOR ANLISO

LOUSER LIFT

RND ELEKTRIK

I. 

LANGKAH AWAL SETING PARAMETER

1. 

POSISIKAN KERETA LIFT DI PERTENGAHAN LANTAI AGAR PINTU KERETA DAPAT

DIKALIBRASI ( INSPECTION MODE ).

2. 

ATUR JARAK BESI SENSOR + 2 mm  DENGAN SENSOR NBDZ (pojok kanan atas pada

hanger door motor).

3.  ATUR DOOR LOCK PADA CAM DOOR MOTOR DENGAN KEMIRINGAN – 2 mm DAN

LOCK HOOK HARUS SALING BERSENTUHAN ADAPUN MAKSIMUM

KERENGGANGAN 1 mm  TIDAK BOLEH LEBIH.

4. 

PADA SAAT SET DOOR LOCK PINTU KERETA HARUS BENAR-BENAR TERTUTUP

RAPAT TIDAK BOLEH BERGERAK DAN CAM DALAM POSISI TERBUKA.

5. 

PASTIKAN CAM DOOR MOTOR TIDAK MIRING.

GB.1 CAM DOOR MOTOR ALINSO

Page 2: ANLISO Setting

7/21/2019 ANLISO Setting

http://slidepdf.com/reader/full/anliso-setting 2/7

CARA SETING PARAMETER DOOR OPERATOR ANLISO

LOUSER LIFT

RND ELEKTRIK

6.  SET POSISI TENGAH ROLLER DOOR LOCK PADA HANGER TERHADAP POSISI

TENGAH CAM DOOR MOTOR, GAMBAR DIBAWAH POSISI ROLLER TERHADAP CAM.

JARAK ( A ) = 8 + 1 mm

JARAK ( B ) = 15 + 1 mm

GB.2 ROLLER HANGER ALINSO

Page 3: ANLISO Setting

7/21/2019 ANLISO Setting

http://slidepdf.com/reader/full/anliso-setting 3/7

CARA SETING PARAMETER DOOR OPERATOR ANLISO

LOUSER LIFT

RND ELEKTRIK

7.  SET DOOR LOCK PADA HANGER DI SEMUA LANTAI DENGAN MAKSIMUM

KERENGGANGAN  2 mm DAN MAKSIMUM KEMIRINGAN 3 mm.

GB.3 DOOR LOCK HANGER ALINSO

8.  POSISIKAN KEMBALI KERETA PADA PERTENGAHAN LANTAI.

9. 

LAKUKAN KALIBRASI INVERTER DOOR MOTOR F018 = 0001.10.

 

ISI F017 = 0001, APABILA TERMINAL P3 SUDAH TERKONEKSI CABUT SOKET

TERMINAL P3 , KEMBALI KE F000.

11. JALANKAN PERINTAH BUKA TUTUP PINTU SECARA MANUAL DENGAN MENEKAN

PANAH TURUN UNTUK MENUTUP DAN PANAH NAIK UNTUK TERBUKA PINTU.

12. 

PERHATIKAN PERGERAKAN PINTU PADA SAAT MENUTUP MAUPUN TERBUKA.

13. APABILA PERGERAKAN BELUM SESUAI LAKUKAN LANGKAH KEDUA UBAH

PARAMETER INVERTER DAN PERHATIKAN GRAFIK YANG ADA PADA INVERTER.

II. 

LANGKAH KEDUA SETING PARAMETER.

PARAMETER KEGUNAAN ISIAN STANDAR DESKRIPSI

F000 TIDAK DI

GUNAKAN

F001AKSELERASIMULAI PINTU

MENUTUP

( 0012 )PULSA JARAKAKSELERASI PADA

SAAT PINTU MULAI

MENUTUP

Page 4: ANLISO Setting

7/21/2019 ANLISO Setting

http://slidepdf.com/reader/full/anliso-setting 4/7

CARA SETING PARAMETER DOOR OPERATOR ANLISO

LOUSER LIFT

RND ELEKTRIK

F002

KECEPATAN

PENUH PINTU

MENUTUP

( 0030 )

KECEPATAN PENUH

PADA SAAT PINTU

MENUTUP

F003

DESELERASI

PINTU MENUTUP

RAPAT

( 0060 )

PULSA JARAK

DESELERASI PADA

SAAT PINTU MULAIMENUTUP RAPAT

F004

KECEPATAN

RENDAH PINTU

MENUTUP

RAPAT

( 0005 )

KECEPATAN RENDAH

PADA SAAT PINTU

MENUTUP RAPAT

F005

JARAK PINTU

MENUTUP

RAPAT

( 0060 )

PULSA JARAK

KECEPATAN RENDAH

PADA SAAT PINTU

MENUTUP RAPAT

F006 KECEPATANCAM DOOR

MOTOR

( 0010 ) KECEPATAN CAM DOORMOTOR MENUTUP

LENGAN CAM

F007

JARAK

KECEPATAN

CAM DOOR

MOTOR

( 0050 )

PULSA JARAK CAM

DOOR MOTOR BEKERJA

MENUTUP LENGAN

CAM SAMPAI

AKSELERASI MULAI

MEMBUKA PINTU

F008

AKSELERASI

MULAI PINTU

MEMBUKA

( 0028 )

PULSA JARAK

AKSELERASI PADA

SAAT PINTU MULAIMEMBUKA

F009

KECEPATAN

PENUH PINTU

MEMBUKA

( 0040 )

KECEPATAN PENUH

PADA SAAT PINTU

MEMBUKA

F010

DESELERASI

PINTU

MEMBUKA

PENUH

( 0015 )

PULSA JARAK

DESELERASI PADA

SAAT PINTU MEMBUKA

PENUH

F011

KECEPATAN

RENDAH PINTU

MEMBUKAPENUH

( 0007 )

KECEPATAN RENDAH

PADA SAAT PINTU

MEMBUKA PENUH

F012

JARAK PINTU

MEMBUKA

PENUH

( 0030 )

PULSA JARAK

KECEPATAN RENDAH

PADA SAAT PINTU

MEMBUKA PENUH

F013 HENTAKAN

PINTU

( 0003 )

HENTAKAN PINTU

PADA SAAT PINTU

MENUTUP KEMBALI

MEMBUKA

F014 WAKTU MULAI ( 0005 )

WAKTU MENGIRIM

SINYAL PADA SAAT

ADA PERINTAH PINTU

MEMBUKA

Page 5: ANLISO Setting

7/21/2019 ANLISO Setting

http://slidepdf.com/reader/full/anliso-setting 5/7

CARA SETING PARAMETER DOOR OPERATOR ANLISO

LOUSER LIFT

RND ELEKTRIK

F015 WAKTU MULAI ( 0005 )

WAKTU MENGIRIM

SINYAL PADA SAAT

ADA PERINTAH PINTU

MENUTUP

F016 ( 0050 )

F019 ( 0050 )

F020 ( 0000 )

III. 

LANGKAH KETIGA PENYESUAIAN PINTU KERETA

DENGAN PINTU LANTAI

1.  SETELAH PERGERAKAN PINTU KERETA SUDAH SESUAI, POSISIKAN KEMBALI

KERETA PADA LEVEL LANTAI (INSPECTION MODE).

2. 

JALANKAN PERINTAH BUKA TUTUP PINTU SECARA MANUAL DENGAN MENEKAN

PANAH TURUN UNTUK MENUTUP DAN PANAH NAIK UNTUK TERBUKA PINTU.

3.  PERHATIKAN PERGERAKAN PINTU PADA SAAT MENUTUP MAUPUN TERBUKA.

4.  APABILA PERGERAKAN BELUM SESUAI LAKUKAN LANGKAH KEDUA UBAH

PARAMETER INVERTER DAN PERHATIKAN GRAFIK YANG ADA PADA INVERTER.

5.  SETELAH PERGERAKAN PINTU KERETA SUDAH SESUAI, PASANG KEMBALI SOKET

TERMINAL P3.

6. 

JALANKAN LIFT AUTO MODE.

SELAMAT BEKERJA