8. abstrak print

Upload: ahmad-zayyin-najah

Post on 09-Jan-2016

212 views

Category:

Documents


0 download

DESCRIPTION

hemodinamik

TRANSCRIPT

PERBEDAAN RATA-RATA TEKANAN DARAH MENURUT JENIS CAIRAN YANG DIBERIKAN PADA PASIEN BEDAH SESAR DENGAN ANESTESI SPINAL DI RSUP NTB TAHUN 2014ABSTRAKLatar Belakang : Masih banyak perbedaan rata-rata tekanan darah dan belum jelasnya jenis pemberian cairan pada pasien bedah sesar dengan anestesi spinal dalam hal menangani perubahan hemodinamik yang terjadi khususnya hipotensi.

Metodelogi Penelitian : Kami meneliti dari 44 pasien yang menjalani bedah sesar dengan spinal. Penentuan kelompok berdasarkan cairan yang diberikan setelah induksi spinal. Dimana terdapat 22 pasien yang diberikan koloid dan 22 pasien yang diberi kristaloid. Observasi dilakukan dengan mengukur tekanan darah sistolik dan diastolik sebelum induksi spinal atau pada menit 0, kemudian menit 1, menit 5, menit 10 dan menit 15 setelah induksi spinal.Hasil Penelitian : Terjadi perbedaan rata-rata tekanan darah sistolik yang bermakna pada menit 5 antara yang diberikan koloid dan kristaloid dimana diperoleh nilai p untuk uji t berpasangan p ( = 0,05) dimana nilai p= 0, 009. Pada menit ke 5 perubahan rata-rata yang terjadi pada kelompok koloid dari 126,59 (SD 14,5) mmHg ke 109,50 (SD 13,9) mmHg, pada kelompok kristaloid dari 131,73 (SD 11,3) mmHg ke 122,73 (SD 16,3) mmHg. Sedangkan pada menit yang lain tidak. Begitu juga pada tekanan darah diastolik tidak ditemukan adanya perbedaan yang bermakna. Akan tetapi, hal ini tidak sesuai dengan teori yang ada.Simpulan : Ada perbedaan yang bermakna rata-rata tekanan darah sistolik pada menit 5 setelah dilakukan anestesi spinal antara kelompok yang diberikan koloid maupun kristaliod. Akan tetapi, perubahan tekanan darah pada kelompok kristaloid lebih tinggi dari pada kelompok koloid. Hal ini kemungkinan dipengaruhi oleh volume pemberian cairan antara koloid dan kristaloid berbeda. Kemungkinan lain adalah pemberian ephedrine setelah anestesi dilakukanKata Kunci : tekanan darah, cairan resusitasi, bedah sesar, anestesi spinalDIFFERENCE IN AVERAGE BLOOD PRESSURE ACCORDING TO THE TYPE OF FLUID ADMINISTERED TO PATIENTS CESAREAN SECTION UNDER SPINAL ANESTHESIA IN HOSPITAL NTB 2014ABSTRACTBeckground : There are many differences in mean blood pressure and unclear the type of fluid administration in patients cesarean section with spinal anesthesia in terms of addressing the hemodynamic changes that occur, especially hypotension.Methods : We examined from 44 patients undergoing cesarean section with spinal. Determination groups based fluids given after induction of spinal. 22 patients were given colloid and crystalloid 22 patients who were given. Observations carried out by measuring the systolic and diastolic blood pressure before induction spinal or at 0 minutes, then 1 minute, 5 minutes, 10 minutes and 15 minutes after induction of spinal.Result : There is a difference mean systolic blood pressure was significant in the 5th minute between colloid and crystalloid given where p values obtained in paired t test p ( = 0.05) where p = 0, 009. At the 5th minute average change average that occurred in the colloid of 126.59 (SD 14.5) mmHg to 109.50 (SD 13.9) mm Hg, the crystalloid group of 131.73 (SD 11.3) mmHg to 122.73 (SD 16.3) mmHg. While the minutes are not. Diastolic blood pressure did not reveal any significant differences. However, this is not in accordance with the existing theory.Conclusion : There were significant differences mean systolic blood pressure in the 5th minute after spinal anesthesia between the groups given colloid or kristaliod. However, changes in blood pressure in the crystalloid group is higher than in the colloid group. This is not in accordance with the theory. Likely influenced by the volume of fluid administration between colloid and crystalloid different. Another possibility is the administration of ephedrine after anesthesia performed.Keyword: blood pressure, fluid resuscitation, cesarean section, spinal anesthesiaxiii