Rancangan Power Aerator Dengan faktor BOD Loading Volume bak aerasi = 1.200 M3 BOD loading = ( 0.3 – 05 )Kg BOD/m3day Untuk mencapai BOD loading 0.5 Kg BOD/ m3day Maka seharusnya : Volume bak =1200 M3 COD in = 3000 ppm Debit = 400 m3/day BOD loading = ( BOD x Q ) / V = 1500 x 400 / 1200 = 0.5 Kg BOD/ m3day MLSS direncanakan 4500 ppm F/M = ( BOD x Q ) / MLVSS x V = ( 1500 x 400 ) / ( 3375 x 1200 ) = 0.148 q = Oksigen transfer rate dari surface aerator ( lihat dispek alat ) bila tidak ada maka diasumsikan sebesar 2.5 – 3.5 lb O2/HP.hr Q = 400 M3/hari = 0.1057 mgd ( 1mgd = 3785 M3/hari ) L = BOD in = 1500 ppm d = densitas air limbah = 8.34 Lb/ Galon P = ( Q x d x L ) / 24 x q = ( 0.1057 x 8.34 x 1500 ) / 24 x 2.5 = 22 HP = 16.53 Kw + 50%(untuk keamanan ) = 16.53 + 8.26 = 24.75 KW = 25 KW Suplai udara ( kalau bentuknya Blower ) Suplai udara = ( 45 – 90 ) m3 / Kg BOD Suplai udara = Suplai udara x BOD load x V

Upload: imyourscin

Post on 22-Jan-2016

7 views

Category:

Documents


0 download

DESCRIPTION

aa

TRANSCRIPT

Page 1: Rancangan Power Aerator Dengan Faktor BOD Loading

● Rancangan Power Aerator Dengan faktor BOD Loading 

Volume bak aerasi = 1.200 M3 BOD loading = ( 0.3 – 05 )Kg BOD/m3day Untuk mencapai BOD loading 0.5 Kg BOD/ m3day 

Maka seharusnya :

Volume bak =1200 M3 COD in = 3000 ppm Debit = 400 m3/day BOD loading = ( BOD x Q ) / V                      = 1500 x 400 / 1200                      = 0.5 Kg BOD/ m3day 

MLSS direncanakan 4500 ppm 

F/M = ( BOD x Q ) / MLVSS x V         = ( 1500 x 400 ) / ( 3375 x 1200 )         = 0.148 

q = Oksigen transfer rate dari surface aerator ( lihat dispek alat ) bila tidak ada maka diasumsikan sebesar 2.5 – 3.5 lb O2/HP.hr Q = 400 M3/hari = 0.1057 mgd ( 1mgd = 3785 M3/hari ) L = BOD in = 1500 ppm d = densitas air limbah = 8.34 Lb/ Galon P = ( Q x d x L ) / 24 x q    = ( 0.1057 x 8.34 x 1500 ) / 24 x 2.5    = 22 HP    = 16.53 Kw + 50%(untuk keamanan )   = 16.53 + 8.26   = 24.75 KW   = 25 KW 

Suplai udara ( kalau bentuknya Blower ) 

Suplai udara = ( 45 – 90 ) m3 / Kg BOD Suplai udara = Suplai udara x BOD load x V                     = 60 m3 / Kg BOD x 0.5 Kg BOD/ m3day x 1200 m3                     = 36000 m3/day