work standar vapor extractor

Upload: achmad-gunawan

Post on 04-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/31/2019 Work Standar Vapor Extractor

    1/4

    Standard

    work

    KPP

    IISM PT KPP #1.2 100MW

    Guidance

    Tgl :2012.10.23 Rev. :0

    Vapor Extractor OperationProcedure

    Page:1/4

    Purpose Of Work :

    Summary work

    Assortment Contents

    Name and Place Of Work 1. Vapor Extractor Operation Procedure

    Important Equipment

    ImportantCheck

    Quality1. Problem :2. Cause :

    Environment

    Safety

    Safety ConsiderationA. BRK input electrical shock cautionB. Work clothes curling caution due to the rotor

    2.Accident Case : Not Applicable

    3.Near-Miss Case : Not Applicable

    4.Fire Case : Not Applicable

    5.Work Permit : Not Applicable

    Preparation

    ActionBeforeWork

    APD Helmet, safety shoes, work gloves, ear plug.

    EquipmentRequired

    Walky talky, valve handle, detector noise & vibration,

    By Achmad Gunawan

  • 7/31/2019 Work Standar Vapor Extractor

    2/4

    Standard

    work

    KPP

    IISM PT KPP #1.2 100MW

    GuidanceRev. :0

    Vapor Extractor OperationProcedure

    Page:3/4

    1. Main Oil Pump Operation (A: Control Room, B: Local)

    Order Of Operations How To Work With Safety /Environment

    (1) Oil quality (If necessary, operate the oilpurifier.)

    (2) Lube oil tank temperature [TE-

    MAV10CT001, TG-MAV10CT501] 10 C

    (In case that oil temperature < 10 C,

    start the main oil tank heater.)

    (3) Oil level of main oil tank (If insufficient, fill

    it up.) [LG-MAV10CL501, LT-MAV10CL001]Flow back oil level.

    (4) Main oil tank drain valve [MAV10AA401,

    402] Fully close

    (5) Main oil tank sampling port valve

    [MAV10AA601]Fully close (after

    checking the quality of oil)

    (6) Main oil tank inlet valve for oil portable

    system [MAV10AA001]Fully close

    (7) Main oil tank vapor extraction return line

    valve [MAV10AA251]Fully close

    (8) Control oil pump-

    A,B[MAX21AP001,002]MANUAL,

    STOP

    (9) Mode selection.

    MODE OPERATION ORDER STAND BY

    AB MODE A B A

    BA MODE B A B

    BRK inputelectrical shockcaution

    1.Control Room Start,A. Control Room Auto start

    - In operation, Pump fault

    - Main Oil Pump Pressure lower (4.6 barg)

    B. Control Room Man start- Graphic in DCS

    Choose Main Oil Pump- Choose Sub window Man Then Start

    1)Check Before OP (B)

    2) MOP start (A)

  • 7/31/2019 Work Standar Vapor Extractor

    3/4

    Standard

    work

    KPP

    IISM PT KPP #1.2 100MW

    Guidance

    Rev. :0

    Vapor Extractor OperationProcedure

    Page:3/4

    1. Vibration Check2. Check Leakage

    3. Main oil pump-A,B discharge Pressure(01/02 MAV21CP201,211) *4.6 BarGStand-by MOP & EOP start autmatically.(*: Setting value corresponds to4.2 BarGat T/G center.)

    4. Main oil tank level (01/02 MAV10CL001)NOL +50 mm (H), NOL -50 mm (L).

    - Confirm that there is no lube oilleakage. If any leakage is found out,repair it.

    - Confirm that main oil tank drain valve isclosed.

    - Fill the tank with lube oil up topermissible level.

    Work clothes

    curling cautiondue to the rotor

    1.Control Room stopControl Room Auto stop (After Stand by start)

    Control Room Man stop- Graphic di DCS

    Choose Main Oil Pump- In Sub window, Choose Man stop

    3)Check After MOPstart(Operation)

    finish

    4) MOP stop(A)

  • 7/31/2019 Work Standar Vapor Extractor

    4/4

    Standard

    work

    KPP

    IISM PT KPP #1.2 100MW

    Guidance

    Rev. :0

    Vapor Extractor OperationProcedure

    Page:4/4

    Main Oil Pump Operation Flow