vinyl sheet pile 2013(1)

Post on 14-Aug-2015

84 Views

Category:

Documents

6 Downloads

Preview:

Click to see full reader

DESCRIPTION

ware

TRANSCRIPT

PT. NUSANTARA SEJAHTERA SEDAYAMARKETING :

Wisma Aldiron 3 Floor, Suite# 317,

Jl. Gatot Subroto Kav. 72, Jakarta 12780

Telp : + 62 21 7990 786 / Fax: +62 21 794 0136

Email : sales@nusantarasteelpile.com

WEREHOUSE :

Gudang Libra

Jl. Gresik Blok 2A No. 10

Marunda - Jakarta Utara

PRODUCT SPECIFICATION

GW 610 / 9

PROPERTY UNIT VALUE THE WIDTH OF THE CROSS-SECTION mm 610

THE HEIGHT OF THE CROSS-SECTION mm 180

THE WALL THICKNESS mm 9,0

THE DENSITY kg / m3 1450-1550

THE ENDURANCE ON THE EXTENDED MATERIAL MPa 40

THE MODULE OF THE ELASTICITY AT THE EXTENSION MPa 2600

THE MODULE OF THE ELASTICITY AT THE INFLEXION MPa 2600

THE MODULE OF THE ELASTICITY AT THE INFLEXION – L. T.* MPa 1000-1500

THE LIMIT OF THE PLASTICITY AT THE COMPRESSION MPa 55-60

THE COEFFICIENT OF THE CROSS-SECTION cm3 / m 1100

THE MOMENT OF INTERIA cm4 / m 12576

ALLOWABLE MOMENT ** kNm / m 14,70

THE MAXIMUM ADMISSIBLE (ULTIMATE) MOMENT kNm / m 44,10

WEIGHT PER UNIT AREA kg / m2

* L. T. – LONG TERM

PT. NUSANTARA SEJAHTERA SEDAYAMARKETING :Wisma Aldiron 3 Floor, Suite# 317,Jl. Gatot Subroto Kav. 72, Jakarta 12780Telp : + 62 21 7990 786 / Fax: +62 21 794 0136Email : sales@nusantarasteelpile.comWEREHOUSE :Gudang LibraJl. Gresik Blok 2A No. 10Marunda - Jakarta Utara

rd

PRODUCT SPECIFICATION

GW 610 / 7,4

PROPERTY UNIT VALUE THE WIDTH OF THE CROSS-SECTION mm 610

THE HEIGHT OF THE CROSS-SECTION mm 180

THE WALL THICKNESS mm 7,4

THE DENSITY kg / m3 1450-1550

THE ENDURANCE ON THE EXTENDED MATERIAL MPa 40

THE MODULE OF THE ELASTICITY AT THE EXTENSION MPa 2600

THE MODULE OF THE ELASTICITY AT THE INFLEXION MPa 2600

THE MODULE OF THE ELASTICITY AT THE INFLEXION – L. T.* MPa 1000-1500

THE LIMIT OF THE PLASTICITY AT THE COMPRESSION MPa 55-60

THE COEFFICIENT OF THE CROSS-SECTION cm3 / m 946

THE MOMENT OF INTERIA cm4 / m 10,788

ALLOWABLE MOMENT ** kNm / m 20,89

THE MAXIMUM ADMISSIBLE (ULTIMATE) MOMENT kNm / m 31,20

WEIGHT PER UNIT AREA kg / m2

* L. T. – LONG TERM

PT. NUSANTARA SEJAHTERA SEDAYAMARKETING :Wisma Aldiron 3 Floor, Suite# 317,Jl. Gatot Subroto Kav. 72, Jakarta 12780Telp : + 62 21 7990 786 / Fax: +62 21 794 0136Email : sales@nusantarasteelpile.comWEREHOUSE :Gudang LibraJl. Gresik Blok 2A No. 10Marunda - Jakarta Utara

rd

PRODUCT SPECIFICATION

GW 610 / 6,4

PROPERTY UNIT VALUE THE WIDTH OF THE CROSS-SECTION mm 610

THE HEIGHT OF THE CROSS-SECTION mm 180

THE WALL THICKNESS mm 6,4

THE DENSITY kg / m3 1450-1550

THE ENDURANCE ON THE EXTENDED MATERIAL MPa 40

THE MODULE OF THE ELASTICITY AT THE EXTENSION MPa 2600

THE MODULE OF THE ELASTICITY AT THE INFLEXION MPa 2600

THE MODULE OF THE ELASTICITY AT THE INFLEXION – L. T.* MPa 1000-1500

THE LIMIT OF THE PLASTICITY AT THE COMPRESSION MPa 55-60

THE COEFFICIENT OF THE CROSS-SECTION cm3 / m 597

THE MOMENT OF INTERIA cm4 / m 5,326

ALLOWABLE MOMENT ** kNm / m 13,17

THE MAXIMUM ADMISSIBLE (ULTIMATE) MOMENT kNm / m 23,10

WEIGHT PER UNIT AREA kg / m2

* L. T. – LONG TERM

PT. NUSANTARA SEJAHTERA SEDAYAMARKETING :Wisma Aldiron 3 Floor, Suite# 317,Jl. Gatot Subroto Kav. 72, Jakarta 12780Telp : + 62 21 7990 786 / Fax: +62 21 794 0136Email : sales@nusantarasteelpile.comWEREHOUSE :Gudang LibraJl. Gresik Blok 2A No. 10Marunda - Jakarta Utara

rd

top related