rekapitulasi beban
DESCRIPTION
rumahTRANSCRIPT
REKAPITULASI BEBAN1. Jumlah daya pada masing-masing grupLantai 1Grup 1:No.RuanganBebanTotal Daya (W)
Lampu TL Stop Kontak
NP(W)Total (W)P(W)
1.Carport13535-36
2.Kamar Tidur11818100118
3.Teras11111-11
4.Taman Depan21428-28
Ruang Tamu11818100118
Jumlah110200310
Grup 2:No.RuanganBebanTotal Daya (W)
Lampu TL Stop Kontak
NP(W)Total (W)P(W)
1.Ruang Makan 13636100136
2.Kamar Mandi188-8
3.Ruang Keluarga24080100180
Jumlah124200324
Grup 3:No.RuanganBebanTotal Daya (W)
Lampu TL Stop Kontak
NP(W)Total (W)P(W)
1.Dapur14040100140
2.Kamar Mandi 2188-8
3.Laundry 11818100118
4.Pantry188-8
5.Taman Belakang21428-28
Jumlah102200302
Lantai 2Grup 4:No.RuanganBebanTotal Daya (W)
Lampu TL Stop Kontak
NP(W)Total (W)P(W)
1.Kamar Tidur11818100118
2.Kamar Mandi188-8
3.KT. Pembantu11111100111
4.KM. Pembantu188-8
5.KT. Utama11818100118
Jumlah63300363
Grup 5:No.RuanganBebanTotal Daya (W)
Lampu TL Stop Kontak
NP(W)Total (W)P(W)
1.Ruang Baca23672100172
2.Balkon21836-36
3.Ruang Santai3824100124
4.Lorong Tangga11111-11
Tempat Menjemur11111-11
Jumlah154200354
2. Besar pengaman masing-masing grup dan pengaman utama pada PHBGrup 1:
MCB yang digunakan sebesar 2 AGrup 2:
MCB yang digunakan sebesar 2 AGrup 3:
MCB yang digunakan sebesar 2 AGrup 4:
MCB yang digunakan sebesar 2 AGrup 5:
MCB yang digunakan sebesar 2 AMaka besar MCB pada PHB adalah 10 A
PERENCANAAN INSTALASI PENERANGAN RUMAH TINGGAL DUA LANTAI TYPE 150/200
Oleh:UMI KARUNIAWATIS1 TTL 2012125514220
JURUSAN TEKNIK ELEKTROFAKULTAS TEKNIKUNIVERSITAS NEGERI SURABAYA2014