Ser vice Manual Philips Domestic Appliances a nd Personal Care Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification Provapor vario new proHI 924 SAP coding HI 924 PRODUCT INFORMATION Feataures : inox sole plate  boiler capacity 1 litre  length steam hose 1,9 metre  length cord set 1,9 metre  maximum steam output 70 gr/min  steam ready indicator  boiler empty indicator Voltage : 220-2 40 V olt Frequency : 50-60 Hz Power consumptium : Boiler : 1200 Watt  Pressure : 3 bar  Iron : 800 Watt 4322 277 00127 00/02 PCS 101 365 Product meets the requirements regarding interference suppression on radio and television. - After the product has been repaired, it should function properly and has to meet the safety requirements as laid down of cially established at this moment. ! Service Information  ! Service Information ! Service Information

Upload: pukymotto

Post on 04-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: iron_vapor_©_ (1)

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 16

Service Manual

Philips Domestic Appliances and Personal Care

Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands copy Copyright reserved Subject to modification

Provapor vario new profi

HI 924

SAP coding HI 924

PRODUCT INFORMATION

Feataures inox sole plate

boiler capacity 1 litre

length steam hose 19 metre

length cord set 19 metre

maximum steam output 70 grmin

steam ready indicator

boiler empty indicator

Voltage 220-240 Volt

Frequency 50-60 Hz

Power consumptium Boiler 1200 Watt

Pressure 3 bar

Iron 800 Watt

4322 277 00127

0002

PCS 101 365

Product meets the requirements regarding interference

suppression on radio and television

- After the product has been repaired it should function

properly and has to meet the safety requirements as laid

down of ficially established at this moment

Service

Information Service

Information

Service

Information

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 26PCS 101 366

EXPLODED VIEW IRON

Screws d x 1

A 30 x 27

B 30 x 25

C 30 x 19

D 30 x 6

E 40 x 12F 30 x 9

G M4 x 24

H 30 x 9

I M4 x 12

DAP1102

5

1

15 8

44

2412

13

14

13

19

16

10

18

6

9

X

4 3 21 11

17232220

2

7

2x

2x

B H

I

2xE

D

C

G

A

F

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 36

PARTS LIST IRON DISASSEMBLY ADVISE IRON

DIAL 1

RING 2

MICROSWITCH 3

LEVER

MICROSWITCH 4

remove SCREW A

remove COVER

MICROSWITCH 5

lift MICROSWITCH 3

unsolder WIRING

Pos Description Service Nummer

Insert dial

Dial ring

Microswitch

Lever microswitch

Cover microswitch

1

2

3

4

5

9965 000 02085

4822 532 12772

4822 282 30239

9965 000 02086

4822 442 00787Handle right + left part

Swivel colour black

Steam hose electric cable

Pilot light

Cork grip

6+7

8

9

10

11

4822 310 10944

4822 325 10193

4822 530 10377

4822 134 10076

4822 498 10638

Clamping ring

Clamping ring

Sleeve

Connecting bracket therm

Metal cover

12

13

14

15

16

4822 492 71001

4822 532 12742

4822 325 10194

4822 402 10689

4822 442 00788

Insulating bracket

Sole plate + pos 19Thermostat

Insulating plate

Bracket + item 22 and 23

17

1819

20

21

4822 466 11473

4822 259 102344822 282 30238

4822 466 11474

4822 310 10945

Hose joint24 4822 526 10669

p

Cutout

Drythermostat

Cut out

TABLE UNIT

Steam-valve

IRON

Steam-switch

Thermostat

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 46

N

PCS 101 367

ADJUSTMENT AND CONTROLS

Thermostat 19

Thermostat ( 19 ) supplied as a spare part or fitted to

the sole plate ( 18 ) has already been adjusted by the

supplier and secured by glue

To avoid disfunction of the iron NEVER readjust the

thermostat

REPLACE

HANDLE 6 + 7

remove SCREW B

remove SCREW C

remove SCREW D

remove SCREW E

D

CE

B

REPLACE SWIVEL 8

REPLACE HOSE 9

REPLACE

PILOT LAMIP 10

disassemble HANDLE

PARTS 6+7

remove SCREW F 2 x

remove CONNECTING

WIRES

remove CLAMP( S )

REPLACE

CORK GRIP 11

disassemble HANDLE

PARTS 6+7

remove SCREW Gremove SCREW H

REPLACE COVER 16

REPLACE

SOLE PLATE 18

REPLACE

THERMOSTAT 19

REPLACE

INSULATING PLATE 20

remove DIAL 1

remove RING 2

remove HANDLE

PARTS 6+7

remove HOSE

remove SLEEVE

remove CORK GRIP

remove SCREW I

remove BRACKET 21

turn conductor B through

180 degrees

remove PLATE 17

THERMOSTAT 19 ONLY

cut CONDUCTOR A

at location P

remove SCREW J

P

Q

BA

D

NOTE

For opening you need a Torx screwdriver 362 TR

T20 x 100

ASSEMBLY

REQUIREMENTS

THERMOSTAT 19

Instead of metal conductor A

the new thermostat has a wire

with AMP clamp

After fixing screw J connect

the AMP clamp to tag Q

After assembling cover 16

ALWAYS turn conductor B

through 180 degrees

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 56

EXPLODED VIEW STAND

PCS 101 368

E

D

DAP1106

31

32

30

33

35

36

34

37

39

36

38

40

42

47

41

46

43

45

44

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 66

PARTS LIST + DISASSEMBLY ADVICE STAND

Pos Description Service Nummer

Stand rubber feet

Rubber feet above screw

Complete tray

Safety valve

Rubber ring in filling hole

30

31

32

33

34

9965 000 01692

9965 000 01702

9965 000 01861

9965 000 01862

9965 000 01866Cover

Rubber feet boiler

Boiler complete

Locked insert

Bottom housing

35

36

37

38

39

9965 000 01892

4822 462 71999

9965 000 01868

9965 000 01788

9965 000 01789

Filter

Switch

Electro valve

Cordset Italian plug

Cordset Europe plug

40

41

42

43

9965 000 01790

9965 000 01791

4822 218 11561

9965 000 01792

9965 000 01793

Steam dial

Steam regulatorBoiler empty lamp

Boiler ready lamp

GBR FRA DEU NLD

ESP PRT ITA

44

4546

47

DFU

9965 000 01899

9965 000 019009965 000 01901

9965 000 01902

4222 001 92450

OPEN THE STAND

D

Below rubber feet

remove SCREW D (1 x)

E

E E

remove SCREW E (3 x)

remove LOCKED INSERT 38

NOTE

OPEN NOW THE STAND

DONrsquoT WORRY IF THE SNAPS AT THE SIDE WILL BE

BROKEN

THEY ARE ONLY FOR THE ASSEMBLY

THE STAND REMAINS CLOSE WITHOUT THESE SNAPS

ADJUSTMENT AND CONTROLS

ndash To avoid leakage of the sealings and damage to

the components in and on the boiler NEVER clean

the boiler with vinegar a descaling agent or otherchemicals

ndash The boiler doesnrsquot contain serviceable parts

Never disassemble the boiler body and or compo-

nents on and in the boiler

ndash ALWAYS REPLACE THE BOILER ( 37 ) WHEN

the mechanical safety valve ( 33 ) has been acti-

vated

the boiler thermostat or hand - resettable safety

thermostat are open because the boiler has

been subjected to too high temperatures

the electrovalve ( 42 ) fails or the sieve is soiled

with scale

ndash After the product has been repaired it should func-

tion properly and has to meet the safety require-

ments as laid down and officially established at this

moment

Page 2: iron_vapor_©_ (1)

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 26PCS 101 366

EXPLODED VIEW IRON

Screws d x 1

A 30 x 27

B 30 x 25

C 30 x 19

D 30 x 6

E 40 x 12F 30 x 9

G M4 x 24

H 30 x 9

I M4 x 12

DAP1102

5

1

15 8

44

2412

13

14

13

19

16

10

18

6

9

X

4 3 21 11

17232220

2

7

2x

2x

B H

I

2xE

D

C

G

A

F

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 36

PARTS LIST IRON DISASSEMBLY ADVISE IRON

DIAL 1

RING 2

MICROSWITCH 3

LEVER

MICROSWITCH 4

remove SCREW A

remove COVER

MICROSWITCH 5

lift MICROSWITCH 3

unsolder WIRING

Pos Description Service Nummer

Insert dial

Dial ring

Microswitch

Lever microswitch

Cover microswitch

1

2

3

4

5

9965 000 02085

4822 532 12772

4822 282 30239

9965 000 02086

4822 442 00787Handle right + left part

Swivel colour black

Steam hose electric cable

Pilot light

Cork grip

6+7

8

9

10

11

4822 310 10944

4822 325 10193

4822 530 10377

4822 134 10076

4822 498 10638

Clamping ring

Clamping ring

Sleeve

Connecting bracket therm

Metal cover

12

13

14

15

16

4822 492 71001

4822 532 12742

4822 325 10194

4822 402 10689

4822 442 00788

Insulating bracket

Sole plate + pos 19Thermostat

Insulating plate

Bracket + item 22 and 23

17

1819

20

21

4822 466 11473

4822 259 102344822 282 30238

4822 466 11474

4822 310 10945

Hose joint24 4822 526 10669

p

Cutout

Drythermostat

Cut out

TABLE UNIT

Steam-valve

IRON

Steam-switch

Thermostat

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 46

N

PCS 101 367

ADJUSTMENT AND CONTROLS

Thermostat 19

Thermostat ( 19 ) supplied as a spare part or fitted to

the sole plate ( 18 ) has already been adjusted by the

supplier and secured by glue

To avoid disfunction of the iron NEVER readjust the

thermostat

REPLACE

HANDLE 6 + 7

remove SCREW B

remove SCREW C

remove SCREW D

remove SCREW E

D

CE

B

REPLACE SWIVEL 8

REPLACE HOSE 9

REPLACE

PILOT LAMIP 10

disassemble HANDLE

PARTS 6+7

remove SCREW F 2 x

remove CONNECTING

WIRES

remove CLAMP( S )

REPLACE

CORK GRIP 11

disassemble HANDLE

PARTS 6+7

remove SCREW Gremove SCREW H

REPLACE COVER 16

REPLACE

SOLE PLATE 18

REPLACE

THERMOSTAT 19

REPLACE

INSULATING PLATE 20

remove DIAL 1

remove RING 2

remove HANDLE

PARTS 6+7

remove HOSE

remove SLEEVE

remove CORK GRIP

remove SCREW I

remove BRACKET 21

turn conductor B through

180 degrees

remove PLATE 17

THERMOSTAT 19 ONLY

cut CONDUCTOR A

at location P

remove SCREW J

P

Q

BA

D

NOTE

For opening you need a Torx screwdriver 362 TR

T20 x 100

ASSEMBLY

REQUIREMENTS

THERMOSTAT 19

Instead of metal conductor A

the new thermostat has a wire

with AMP clamp

After fixing screw J connect

the AMP clamp to tag Q

After assembling cover 16

ALWAYS turn conductor B

through 180 degrees

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 56

EXPLODED VIEW STAND

PCS 101 368

E

D

DAP1106

31

32

30

33

35

36

34

37

39

36

38

40

42

47

41

46

43

45

44

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 66

PARTS LIST + DISASSEMBLY ADVICE STAND

Pos Description Service Nummer

Stand rubber feet

Rubber feet above screw

Complete tray

Safety valve

Rubber ring in filling hole

30

31

32

33

34

9965 000 01692

9965 000 01702

9965 000 01861

9965 000 01862

9965 000 01866Cover

Rubber feet boiler

Boiler complete

Locked insert

Bottom housing

35

36

37

38

39

9965 000 01892

4822 462 71999

9965 000 01868

9965 000 01788

9965 000 01789

Filter

Switch

Electro valve

Cordset Italian plug

Cordset Europe plug

40

41

42

43

9965 000 01790

9965 000 01791

4822 218 11561

9965 000 01792

9965 000 01793

Steam dial

Steam regulatorBoiler empty lamp

Boiler ready lamp

GBR FRA DEU NLD

ESP PRT ITA

44

4546

47

DFU

9965 000 01899

9965 000 019009965 000 01901

9965 000 01902

4222 001 92450

OPEN THE STAND

D

Below rubber feet

remove SCREW D (1 x)

E

E E

remove SCREW E (3 x)

remove LOCKED INSERT 38

NOTE

OPEN NOW THE STAND

DONrsquoT WORRY IF THE SNAPS AT THE SIDE WILL BE

BROKEN

THEY ARE ONLY FOR THE ASSEMBLY

THE STAND REMAINS CLOSE WITHOUT THESE SNAPS

ADJUSTMENT AND CONTROLS

ndash To avoid leakage of the sealings and damage to

the components in and on the boiler NEVER clean

the boiler with vinegar a descaling agent or otherchemicals

ndash The boiler doesnrsquot contain serviceable parts

Never disassemble the boiler body and or compo-

nents on and in the boiler

ndash ALWAYS REPLACE THE BOILER ( 37 ) WHEN

the mechanical safety valve ( 33 ) has been acti-

vated

the boiler thermostat or hand - resettable safety

thermostat are open because the boiler has

been subjected to too high temperatures

the electrovalve ( 42 ) fails or the sieve is soiled

with scale

ndash After the product has been repaired it should func-

tion properly and has to meet the safety require-

ments as laid down and officially established at this

moment

Page 3: iron_vapor_©_ (1)

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 36

PARTS LIST IRON DISASSEMBLY ADVISE IRON

DIAL 1

RING 2

MICROSWITCH 3

LEVER

MICROSWITCH 4

remove SCREW A

remove COVER

MICROSWITCH 5

lift MICROSWITCH 3

unsolder WIRING

Pos Description Service Nummer

Insert dial

Dial ring

Microswitch

Lever microswitch

Cover microswitch

1

2

3

4

5

9965 000 02085

4822 532 12772

4822 282 30239

9965 000 02086

4822 442 00787Handle right + left part

Swivel colour black

Steam hose electric cable

Pilot light

Cork grip

6+7

8

9

10

11

4822 310 10944

4822 325 10193

4822 530 10377

4822 134 10076

4822 498 10638

Clamping ring

Clamping ring

Sleeve

Connecting bracket therm

Metal cover

12

13

14

15

16

4822 492 71001

4822 532 12742

4822 325 10194

4822 402 10689

4822 442 00788

Insulating bracket

Sole plate + pos 19Thermostat

Insulating plate

Bracket + item 22 and 23

17

1819

20

21

4822 466 11473

4822 259 102344822 282 30238

4822 466 11474

4822 310 10945

Hose joint24 4822 526 10669

p

Cutout

Drythermostat

Cut out

TABLE UNIT

Steam-valve

IRON

Steam-switch

Thermostat

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 46

N

PCS 101 367

ADJUSTMENT AND CONTROLS

Thermostat 19

Thermostat ( 19 ) supplied as a spare part or fitted to

the sole plate ( 18 ) has already been adjusted by the

supplier and secured by glue

To avoid disfunction of the iron NEVER readjust the

thermostat

REPLACE

HANDLE 6 + 7

remove SCREW B

remove SCREW C

remove SCREW D

remove SCREW E

D

CE

B

REPLACE SWIVEL 8

REPLACE HOSE 9

REPLACE

PILOT LAMIP 10

disassemble HANDLE

PARTS 6+7

remove SCREW F 2 x

remove CONNECTING

WIRES

remove CLAMP( S )

REPLACE

CORK GRIP 11

disassemble HANDLE

PARTS 6+7

remove SCREW Gremove SCREW H

REPLACE COVER 16

REPLACE

SOLE PLATE 18

REPLACE

THERMOSTAT 19

REPLACE

INSULATING PLATE 20

remove DIAL 1

remove RING 2

remove HANDLE

PARTS 6+7

remove HOSE

remove SLEEVE

remove CORK GRIP

remove SCREW I

remove BRACKET 21

turn conductor B through

180 degrees

remove PLATE 17

THERMOSTAT 19 ONLY

cut CONDUCTOR A

at location P

remove SCREW J

P

Q

BA

D

NOTE

For opening you need a Torx screwdriver 362 TR

T20 x 100

ASSEMBLY

REQUIREMENTS

THERMOSTAT 19

Instead of metal conductor A

the new thermostat has a wire

with AMP clamp

After fixing screw J connect

the AMP clamp to tag Q

After assembling cover 16

ALWAYS turn conductor B

through 180 degrees

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 56

EXPLODED VIEW STAND

PCS 101 368

E

D

DAP1106

31

32

30

33

35

36

34

37

39

36

38

40

42

47

41

46

43

45

44

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 66

PARTS LIST + DISASSEMBLY ADVICE STAND

Pos Description Service Nummer

Stand rubber feet

Rubber feet above screw

Complete tray

Safety valve

Rubber ring in filling hole

30

31

32

33

34

9965 000 01692

9965 000 01702

9965 000 01861

9965 000 01862

9965 000 01866Cover

Rubber feet boiler

Boiler complete

Locked insert

Bottom housing

35

36

37

38

39

9965 000 01892

4822 462 71999

9965 000 01868

9965 000 01788

9965 000 01789

Filter

Switch

Electro valve

Cordset Italian plug

Cordset Europe plug

40

41

42

43

9965 000 01790

9965 000 01791

4822 218 11561

9965 000 01792

9965 000 01793

Steam dial

Steam regulatorBoiler empty lamp

Boiler ready lamp

GBR FRA DEU NLD

ESP PRT ITA

44

4546

47

DFU

9965 000 01899

9965 000 019009965 000 01901

9965 000 01902

4222 001 92450

OPEN THE STAND

D

Below rubber feet

remove SCREW D (1 x)

E

E E

remove SCREW E (3 x)

remove LOCKED INSERT 38

NOTE

OPEN NOW THE STAND

DONrsquoT WORRY IF THE SNAPS AT THE SIDE WILL BE

BROKEN

THEY ARE ONLY FOR THE ASSEMBLY

THE STAND REMAINS CLOSE WITHOUT THESE SNAPS

ADJUSTMENT AND CONTROLS

ndash To avoid leakage of the sealings and damage to

the components in and on the boiler NEVER clean

the boiler with vinegar a descaling agent or otherchemicals

ndash The boiler doesnrsquot contain serviceable parts

Never disassemble the boiler body and or compo-

nents on and in the boiler

ndash ALWAYS REPLACE THE BOILER ( 37 ) WHEN

the mechanical safety valve ( 33 ) has been acti-

vated

the boiler thermostat or hand - resettable safety

thermostat are open because the boiler has

been subjected to too high temperatures

the electrovalve ( 42 ) fails or the sieve is soiled

with scale

ndash After the product has been repaired it should func-

tion properly and has to meet the safety require-

ments as laid down and officially established at this

moment

Page 4: iron_vapor_©_ (1)

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 46

N

PCS 101 367

ADJUSTMENT AND CONTROLS

Thermostat 19

Thermostat ( 19 ) supplied as a spare part or fitted to

the sole plate ( 18 ) has already been adjusted by the

supplier and secured by glue

To avoid disfunction of the iron NEVER readjust the

thermostat

REPLACE

HANDLE 6 + 7

remove SCREW B

remove SCREW C

remove SCREW D

remove SCREW E

D

CE

B

REPLACE SWIVEL 8

REPLACE HOSE 9

REPLACE

PILOT LAMIP 10

disassemble HANDLE

PARTS 6+7

remove SCREW F 2 x

remove CONNECTING

WIRES

remove CLAMP( S )

REPLACE

CORK GRIP 11

disassemble HANDLE

PARTS 6+7

remove SCREW Gremove SCREW H

REPLACE COVER 16

REPLACE

SOLE PLATE 18

REPLACE

THERMOSTAT 19

REPLACE

INSULATING PLATE 20

remove DIAL 1

remove RING 2

remove HANDLE

PARTS 6+7

remove HOSE

remove SLEEVE

remove CORK GRIP

remove SCREW I

remove BRACKET 21

turn conductor B through

180 degrees

remove PLATE 17

THERMOSTAT 19 ONLY

cut CONDUCTOR A

at location P

remove SCREW J

P

Q

BA

D

NOTE

For opening you need a Torx screwdriver 362 TR

T20 x 100

ASSEMBLY

REQUIREMENTS

THERMOSTAT 19

Instead of metal conductor A

the new thermostat has a wire

with AMP clamp

After fixing screw J connect

the AMP clamp to tag Q

After assembling cover 16

ALWAYS turn conductor B

through 180 degrees

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 56

EXPLODED VIEW STAND

PCS 101 368

E

D

DAP1106

31

32

30

33

35

36

34

37

39

36

38

40

42

47

41

46

43

45

44

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 66

PARTS LIST + DISASSEMBLY ADVICE STAND

Pos Description Service Nummer

Stand rubber feet

Rubber feet above screw

Complete tray

Safety valve

Rubber ring in filling hole

30

31

32

33

34

9965 000 01692

9965 000 01702

9965 000 01861

9965 000 01862

9965 000 01866Cover

Rubber feet boiler

Boiler complete

Locked insert

Bottom housing

35

36

37

38

39

9965 000 01892

4822 462 71999

9965 000 01868

9965 000 01788

9965 000 01789

Filter

Switch

Electro valve

Cordset Italian plug

Cordset Europe plug

40

41

42

43

9965 000 01790

9965 000 01791

4822 218 11561

9965 000 01792

9965 000 01793

Steam dial

Steam regulatorBoiler empty lamp

Boiler ready lamp

GBR FRA DEU NLD

ESP PRT ITA

44

4546

47

DFU

9965 000 01899

9965 000 019009965 000 01901

9965 000 01902

4222 001 92450

OPEN THE STAND

D

Below rubber feet

remove SCREW D (1 x)

E

E E

remove SCREW E (3 x)

remove LOCKED INSERT 38

NOTE

OPEN NOW THE STAND

DONrsquoT WORRY IF THE SNAPS AT THE SIDE WILL BE

BROKEN

THEY ARE ONLY FOR THE ASSEMBLY

THE STAND REMAINS CLOSE WITHOUT THESE SNAPS

ADJUSTMENT AND CONTROLS

ndash To avoid leakage of the sealings and damage to

the components in and on the boiler NEVER clean

the boiler with vinegar a descaling agent or otherchemicals

ndash The boiler doesnrsquot contain serviceable parts

Never disassemble the boiler body and or compo-

nents on and in the boiler

ndash ALWAYS REPLACE THE BOILER ( 37 ) WHEN

the mechanical safety valve ( 33 ) has been acti-

vated

the boiler thermostat or hand - resettable safety

thermostat are open because the boiler has

been subjected to too high temperatures

the electrovalve ( 42 ) fails or the sieve is soiled

with scale

ndash After the product has been repaired it should func-

tion properly and has to meet the safety require-

ments as laid down and officially established at this

moment

Page 5: iron_vapor_©_ (1)

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 56

EXPLODED VIEW STAND

PCS 101 368

E

D

DAP1106

31

32

30

33

35

36

34

37

39

36

38

40

42

47

41

46

43

45

44

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 66

PARTS LIST + DISASSEMBLY ADVICE STAND

Pos Description Service Nummer

Stand rubber feet

Rubber feet above screw

Complete tray

Safety valve

Rubber ring in filling hole

30

31

32

33

34

9965 000 01692

9965 000 01702

9965 000 01861

9965 000 01862

9965 000 01866Cover

Rubber feet boiler

Boiler complete

Locked insert

Bottom housing

35

36

37

38

39

9965 000 01892

4822 462 71999

9965 000 01868

9965 000 01788

9965 000 01789

Filter

Switch

Electro valve

Cordset Italian plug

Cordset Europe plug

40

41

42

43

9965 000 01790

9965 000 01791

4822 218 11561

9965 000 01792

9965 000 01793

Steam dial

Steam regulatorBoiler empty lamp

Boiler ready lamp

GBR FRA DEU NLD

ESP PRT ITA

44

4546

47

DFU

9965 000 01899

9965 000 019009965 000 01901

9965 000 01902

4222 001 92450

OPEN THE STAND

D

Below rubber feet

remove SCREW D (1 x)

E

E E

remove SCREW E (3 x)

remove LOCKED INSERT 38

NOTE

OPEN NOW THE STAND

DONrsquoT WORRY IF THE SNAPS AT THE SIDE WILL BE

BROKEN

THEY ARE ONLY FOR THE ASSEMBLY

THE STAND REMAINS CLOSE WITHOUT THESE SNAPS

ADJUSTMENT AND CONTROLS

ndash To avoid leakage of the sealings and damage to

the components in and on the boiler NEVER clean

the boiler with vinegar a descaling agent or otherchemicals

ndash The boiler doesnrsquot contain serviceable parts

Never disassemble the boiler body and or compo-

nents on and in the boiler

ndash ALWAYS REPLACE THE BOILER ( 37 ) WHEN

the mechanical safety valve ( 33 ) has been acti-

vated

the boiler thermostat or hand - resettable safety

thermostat are open because the boiler has

been subjected to too high temperatures

the electrovalve ( 42 ) fails or the sieve is soiled

with scale

ndash After the product has been repaired it should func-

tion properly and has to meet the safety require-

ments as laid down and officially established at this

moment

Page 6: iron_vapor_©_ (1)

8132019 iron_vapor_copy_ (1)

httpslidepdfcomreaderfullironvapor-1 66

PARTS LIST + DISASSEMBLY ADVICE STAND

Pos Description Service Nummer

Stand rubber feet

Rubber feet above screw

Complete tray

Safety valve

Rubber ring in filling hole

30

31

32

33

34

9965 000 01692

9965 000 01702

9965 000 01861

9965 000 01862

9965 000 01866Cover

Rubber feet boiler

Boiler complete

Locked insert

Bottom housing

35

36

37

38

39

9965 000 01892

4822 462 71999

9965 000 01868

9965 000 01788

9965 000 01789

Filter

Switch

Electro valve

Cordset Italian plug

Cordset Europe plug

40

41

42

43

9965 000 01790

9965 000 01791

4822 218 11561

9965 000 01792

9965 000 01793

Steam dial

Steam regulatorBoiler empty lamp

Boiler ready lamp

GBR FRA DEU NLD

ESP PRT ITA

44

4546

47

DFU

9965 000 01899

9965 000 019009965 000 01901

9965 000 01902

4222 001 92450

OPEN THE STAND

D

Below rubber feet

remove SCREW D (1 x)

E

E E

remove SCREW E (3 x)

remove LOCKED INSERT 38

NOTE

OPEN NOW THE STAND

DONrsquoT WORRY IF THE SNAPS AT THE SIDE WILL BE

BROKEN

THEY ARE ONLY FOR THE ASSEMBLY

THE STAND REMAINS CLOSE WITHOUT THESE SNAPS

ADJUSTMENT AND CONTROLS

ndash To avoid leakage of the sealings and damage to

the components in and on the boiler NEVER clean

the boiler with vinegar a descaling agent or otherchemicals

ndash The boiler doesnrsquot contain serviceable parts

Never disassemble the boiler body and or compo-

nents on and in the boiler

ndash ALWAYS REPLACE THE BOILER ( 37 ) WHEN

the mechanical safety valve ( 33 ) has been acti-

vated

the boiler thermostat or hand - resettable safety

thermostat are open because the boiler has

been subjected to too high temperatures

the electrovalve ( 42 ) fails or the sieve is soiled

with scale

ndash After the product has been repaired it should func-

tion properly and has to meet the safety require-

ments as laid down and officially established at this

moment