ConCePTPower DPATM
Sae-Swap Modular UPS Systems
or Continuous Power Protection Availability
English
-
8/3/2019 DPA ING_WEB_290509
2/8
C O N C E P T P O W E R D PAT M 8 - 2 0 0 k W
Technical specifications
Specifcationsaresubjecttochange
withoutnotice.
10/8 15/12 20/16 25/20 30/24 40/32 45/40
28.5 31 33 35 44 53 56
CONCEPTPOWER DPATM
MD-FRAMES
UPS-modules, pcsInbuilt BatteriesOutput Power, kVA / kWDimensions (WxHxD)Weight with all modules
CONCEPTPOWER DPA
MX-FRAMES
UPS-modules, pcsInbuilt Batteries
Output Power, kVA / kWDimensions (WxHxD)Weight with all modules
CONCEPTPOWER DPA
SAFE-SWAP MODULES
Nominal Output PowerTopologyParallel confgurationINPUTNominal VoltageFrequency
Power FactorHarmonic Current Distortion THDIOUTPUTVoltageFrequencyVoltage DistortionOverloading CapabilityCrest FactorEFFICIENCYLoad 100/ 75/ 50/ 25%Eco-Mode at 100% LoadENVIRONMENT
Storage TemperatureOperating TemperatureMaximum AltitudeCOMMUNICATIONSModular LevelFrame Level
OptionsWEIGHT, DIMENSIONSWeightDimensions (WxHxD)STANDARDS
SaetyElectromagnetic Comp. (EMC)
PerormanceProduct CertifcationEnclosureManuacturingCountry o origin
Max.
Max.mmkg
Max.
Max.mmkg
kVA/kW
VHz
%
VHz%%
%%
CCm
kgmm
CLASSIC DPA-25UPS+BATTERY1Yes25/20550x1650x780Up to 215
CLASSIC DPA-50UPS+BATTERY1Yes
50/40730x1650x800Up to 318
TRIPLE DPA-75UPS+BATTERY13Yes75/60550x1975x780Up to 323
TRIPLE DPA-150UPS+BATTERY13Yes
150/120730x1975x800Up to 407
UPGRADE DPA-125UPS15No125/100550x1975x780Up to 346
UPGRADE DPA-250UPS15No
250/200730x1975x800Up to 485
CBAT DPA-120BATTERY-Battery only-730x1975x800290 (with trays & w/outbatteries)
CBAT DPA-200BATTERY-Battery only
-1200x1975x800410 (with trays & w/out
batteries)
True double conversion on-line (VFI-SS-111)True modularity, Distributed Parallel Architecture DPA (up to 20 modules)
3 x 380/220+N, 3 x 400/230+N, 3 x 415/240+N (-23%,+15% @ 400V)35 - 70
0,99 @ 100% load< 3% @ 100% load (sinewave)
3 x 380/220+N, 3 x 400/230+N, 3 x 415/240+N50 or 60
< 1,5% @ linear load, < 2% @ non-linear load (IEC/EN 62040-3)125% / 10 min, 150% / 60 s
3 : 1
Up to 96 / 95.5 / 95 / 94, AC-AC on-line mode98
-25+700+401000 m without derating, max. 3000 m
Power Management Display (PMD), 1x RS 2322 x RS232 (SMART PORTS), 1 x USB, 2 x empty slots or options Customer Input Interaces(Remote shutdown, GENSET-ON, Temperature) Customer Output Interaces (10 x Dry Ports)
Additional COM-Cards (SNMP, Newavewatch )
483x225x700 663x225x720
IEC/EN 62040-1-1, IEC/EN 60950-1IEC/EN 61000-6-4 (product standard IEC/EN 62040-2 limit A (C2 UPS))IEC/EN 61000-6-2 (product standard IEC/EN 62040-2 Criterion A(C2 UPS))
IEC/EN 61000-4-2, IEC/EN 61000-4-3, IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-6IEC/EN 62040-3CE, GOST by TV
IP 20ISO 9001:2000Switzerland
For MD-Frames For MX-Frames
-
8/3/2019 DPA ING_WEB_290509
3/8
Conceptpower DPATM highlights at a glance
Decentralized Parallel Architecture for mission-critical applications
The rapid growth o data centerswith mission critical applicationsthat are undamentally immune toplanned and unplanned downtime haveincreased the demand or continuousavailability, fexibility, serviceability andperormance.
Newaves newest modular UPS designConceptpower DPATM (DecentralizedParallel Architecture) with uniqueSae-Swap Modules (SSM) addressesall the availability concerns related to
power protection o mission criticalapplications.The move to high power densityblade servers has caused a shit inthe perormance o advanced powerprotection systems.
High power density, high eciencyand no power derating with leadingloads have become the key eatures omodern UPS Systems.
High power density (200kW per rack)For foor space saving
DPA with Sae-Swap Modules (SSM)For premium power protection availability
Low Total Cost o Ownership (TCO) Cost saving during entire lie-cycle
Flexibility / Scalability Ease o power upgrade, pay as you grow
Enhanced Serviceability Rapid ault recovery
Link to NewavewatchTM
Instantaneous ault recognition
-
8/3/2019 DPA ING_WEB_290509
4/8
C O N C E P T P O W E R D PAT M
What is Decentralized Parallel Architecture (DPA)?
How to achieve highest power protection availability levels
Premium Availability: DPA with Sae-Swap ModulesMAINS 1 MAINS 2
BATTERY
BATTERY
CRITICAL
LOAD
UPSSTATIC
BYPASS
UPSSTATIC
BYPASS
UPSSTATIC
BYPASS
BATTERY
Have you identied the level o
consequential loss o your operation
in the event o an outage?
Understanding the risk level and
translating it into power protection
availability requirements is essential.
For more than a decade Newave has
been designing high availability andresiliant power protection concepts
to help IT and acility managers to
easily tailor their power protection
systems to meet highest availability
requirements.
High power protection availability
is achieved by combining the
double conversion technology (high
reliability), advanced redundant
parallel architecture (high availability)
and Sae-Swap modular technique
(premium availability).
To maintain the premium availability
in time and hence achieve
Continuous Power Protection
Availability, Newave has designed
NewavewatchTM an advanced,
maintenance based, Remote
Monitoring and Management System.
To achieve near-zero downtime
and avoid very costly consequences
o disruption o mission critical
applications, advanced DecentralizedParallel Architectures providing
high availability must be employed.
NEWAVES new second generation
modular Conceptpower DPATM is
based on a unique Sae-Swap technique
to provide premium availability.
NEWAVES Decentralized Parallel Architecture (DPA)TM is based
on independent Sae-Swap Modules (SSM) that include virtually
the entire UPS hardware and sotware and hence eliminating all
common parts which are potential single points o ailures. A Sae-
Swap DPA-Module includes distributed CPUS, distributed control
panels, distributed power units and distributed static bypass
switches. The batteries are separately congured or each module.
-
8/3/2019 DPA ING_WEB_290509
5/8
8 - 2 0 0 k W
NewavewatchTM
What is Sae-Swap Modularity (SSM)?
When adding or replacing modules
in a power protection system that
supplies a mission critical application
it is o paramount importance to
understand how sae it is to perorm
this very delicate operation?
A Modul is Saf-Sappabl if:
It is hot-swappable, meaning
hot insertion or hot removal o
modules rom a host system by
means o plugs or connectors
without removing the power to
the load
It is replaceable without transer-
ring the load to raw mains
(true Hot-Swap, no downtime,
no risk)
It is designed or easy and
sae swapping (secure module
isolation rom rest o the system),
meaning the replacement or
scaling is achieved without any
risk o manipulation errors that
may cause damage to the module,
system or even cause a load
crash.
NEWAVES unique Sae-Swap
ModularTechnique is a true Sae-
Swap modular concept that allows
easy (plug-and-play) scaling and/or
replacing o modules whilst the
load continues to be supplied by
sae UPS power. The load must not
be transerred to unreliable raw
mains or even be interrupted. This
is unique and perectly responds to
todays data centre requirements
where planned computer shutdowns
are becoming a rarity.
A common misconception o a UPSis that it is a commission-and-
orget solution. UPS units are
complex equipments and however
well designed and manuactured they
require regular maintenance and
monitoring in order to maintain the
highest availability o your power
protection system and hence not
allow to compromise the uptime o
mission-critical applications.
To ensure early recognition oanomalies and short recovery times
NEWAVE has developed an advanced
Remote Monitoring and Management
System NewavewatchTM to tackle the
anomalies at an early stage and beore
they cause more important
consequences or even downtimeso mission-critical applications.
NewavewatchTM has a unique
redundant communication option by
means o modem, GSM or through
the internet.
WATCH represents the integration
o an eective UPS management
and service that should be regarded
as an essential element o a power
protection solution. Mission critical
systems require constant availability othe power protection inrastructure.
Continuous monitoring in the orm
o NewavewatchTM is an aordable
insurance policy designed to detect
and warn o problems beore they
become a crisis.
NEWAVEs expert engineers atthe Master (Switzerland) or Local
Service Centre are always at hand to
help diagnose and resolve problems,
quickly and eciently.
-
8/3/2019 DPA ING_WEB_290509
6/8
Why is TCO so important?
Low losses at partial loads will result in major energy savings
Rightsizing of the Power Protection System Over Time
P a y a s y o u g r o w
Capacity in%
ROOM CAPACITY
EXPECTED LOAD
INSTALLED CAPACITY
Waste due to oversizing
ACTUAL LOAD
YEARS
95.59595
Load in %
Eciency in %
97
96
95
94
93
95.5
UPS systems operate 24h a day and
365 days a year and during more
then 10 years.
The Total Cost o Ownership (TCO)
o a UPS System during its liecycle
is typically a multiple o the initial
investment cost o the UPS system.
The major impact on TCO
have ollowing parameters:
UPS eciency at partial/ull load;
Cooling system eciency;
Rightsizing the system power over
time;
Adding power without need o
additional foor space;
Input PF and THDi.
The major impact on the lie-cycle
cost o a UPS system is generated
by the operating losses. The emitted
heat in data centres must be
evacuated by appropriate cooling
systems that also generate losses and
hence increase the overall operating
losses.
In redundant UPS congurations
single modules operate at partial
loads typically at 40-60% o the rated
UPS power.
Conceptpower DPATM with its
unique Energy Saving Inverter
Switching (ESIS) technique has been
designed to provide high eciencies
at partial and at rated loads. The
diagram below shows Conceptpower
DPATM fat eciency curve with high
eciencies even at very low partial
loads.
Thanks to the ability o true modular
UPS systems to easily scale power,
it is possible to add power as the
data centre power requirements
grow. This eliminates the high initial
investment cost o purchasing power
capacity that is not required at the
stage o installation and hence it
helps avoid waste due to over sizing.
In addition, the correct sizing o the
power protection system during the
entire lie-cycle helps keep the totalcost o ownership low.
The unique Conceptpower DPATM
modular design with Sae-Swap
modules guarantees sae power
upgrading without the need o
removing the power nor transerring
the load to raw mains.
Power capacity can be added up to
200kW (250kVA) in one single rack
without increasing the oot-print. I
the power requirements grow above
200kW additional racks can be added
to provide up to 800kW (900kVA)power.
-
8/3/2019 DPA ING_WEB_290509
7/8
Low input THDi and near unity PF results major installations savings
DPA was designed to reduce material contents
DPA was designed to use materials to reduce environmental impact
Input THDi in %
Load in %
LeADInG LAGGInG
without dratig
Load in %
0.92
0.960.98 0.99
3,4
2,4 2,32,0
Thanks to the advanced transormer-
less design the modules are very
compact in size and weight. Up to 5
modules can be accommodated into
a single space-saving rack reaching
highest power density o up to
342kW/m2.
Blade servers have leading power
actors and thereore require adequate
UPS power.
Conceptpower DPATM provides ull
rated power in the range o 0.9-leading
to 0.8-lagging power actors. Thus
saving valuable data centre foor space.
The reduction o the material contents
results in saving o natural resources
and decreases the environmental
impact.
In addition, the compact size o the
modular Conceptpower DPATM
saves packaging weight and decreases
substantially energy consumption in
transport to customers.
Conceptpower DPATM Advanced
Booster Technology (ABT) generates
a near unity input power actor and
reduces the input THDi to values
-
8/3/2019 DPA ING_WEB_290509
8/8Rev.2-
08/08
ABBAcerAEG SVSAmerican British RacingAmerican ExpressAnsar AlmojahedinARGE NS LtschbergAXA Insurance
Bank Renaissance MoscowBank Vontobel AGBarclays BankBasijian InstituteBasler VersicherungBBC (British Broadcasting Corp.)BelgorodenergoBetty BarclayBlaupunktBLS Ltschbergbahn AGBNFL (British Nuclear Fuels Ltd.)Boehringer IngelheimBritish Airport Authority (BAA)British CouncilBritish TelecomBrgerspital St. GallenCable and WirelessCambridge University
CaterpillarCentral Bank o Russian FederationCepsaCoca ColaCore TelecomCorreos de EspaaCredit SuisseDachserDaimler AGDanossDeutsche PostDNAEADSEDEKAEDP (Electricity o Portugal)ElisaEnoEterraFujitsuGestamp CorporationGlaxo Smith KlineHenkelHiltonHoneywellHSBCHyattIBERIAIBMIntelInterouteIran InsuranceIran Telecom (TCI)IXEurope (Switzerland) AGKaraarin BankLekkerlandLloyds TSBLonza AG
LUKOILManor AGMehilinenMeridienMeteorological OceMetropolitano de LisboaMigros Ostschweiz
Mobile TeleSystems (MTS)MobistarMotorolaNATs (National Air Trac control)NestlNokian RenkaatNovartis Consumer Health Schweiz AGNueld Hospitals
O2Oc (Schweiz) AGOlviOracle CorporationOSCE KosovaOsuuspankkikeskusOutokumpuOxord UniversityPaulanerPortugal TelecomProcter & GambleRabo BankRadio Televisin EspaolaREFER (Protuguese Railways)REPSOL-YPFRittalRitzRohde & Schwarz
Rolex SAROS TelecomRoshals medical clinicRoyal Bank o ScotlandRoyal ScandinaviaRussian RailwaysSampo PankkiSchiphol AirportSchweiz. Bundesbahnen SBBScottish PowerSheratonSiemens Schweiz AGSoudronic AGStora EnsoStudienzentrum GerzenseeSwiss RailwaySwiss ReinsuranceT-mobileTechnionTechnische BetriebeTedjarat BankTelekurs Services AGTescoThalesTiebauamt NidwaldenTool-TempUnied Energy System o RussiaUnited Bank o Switzerland (UBS)UPM-KymmeneWaitroseVAPOVeikkausWilliamsWinterthur-Assurance p.a. wincasaVneshtorgbankVnukovo Airport MoscowVodaone
Wolseleyvon Moos Stahl AGVR-RataZiegler Papier AGZurichZrcher Kantonalbank
Subsidiaries
Austia
Newave sterreich GmbHUngargasse 36A-1030 WiensterreichTel. +43 (1) 710 96 70 16
Fax +43 (1) 710 96 70 [email protected]
Bazil
Newave South America LTDARua Clodomiro Amazonas No. 1422Suite 68BR-04537-002 - So PauloTel. +55 11 3045 0809Fax +55 11 3045 [email protected]
Filad
Newave Finland OYNiittlyntie 5 (postal)Lkkisepnkuja 6 (visiting)FIN-00620 HelsinkiTel. +358 9 751 46 100Fax +358 9 751 46 [email protected].
Gmay
Newave USV Systeme GmbHSummerside Ave. C 207Baden AirparkD-77386 RheinmnsterTel. +49 7229 1866-0Fax +49 7229 [email protected]
Hg Kg & Chia
Newave Energy Hong Kong ltdRoom 2506, West Tower, Shun TakCentreHK-168-200 Connaught RoadCentralTel. [email protected]
with branch ofce in China:
Newave Energy (Jiangmen) Limited
9/F Kawa House, 49 Jiangshe Road,Jiangmen, GuangDong, ChinaPostal Code: 529000Tel. +86 750 3680239Fax +86 750 3680229ino @newave.cn.comwww.newave.com.cn
Idia
Newave Energy India Private Limited102/103 Tanishka, Akurli Road,Near Big Bazar, Kandivali EastIN-400 101 MumbaiTel. +91 (22) 42179292
Fax +91 (22) [email protected]
Italy
NEWAVE ItaliaVia Vincenzo Ussani, 90I-00151 RomaTel. +39 06 87451674Fax. +39 06 [email protected]
Spai
Newave Espaa SAArturo Soria 329 1 DES-28033 MadridTel. +34 (91) 768 22 22Fax +34 (91) 383 21 [email protected]
Sitzlad
ServiceNet AGIndustriestrasse 5CH-5432 NeuenhoTel. +41 56 416 01 01Fax +41 56 416 01 [email protected]
with branch ofce in Biel:
Am Wald 36CH-2504 BielSwitzerlandTel. +41 32 366 60 30Fax +41 32 366 60 [email protected]
Th nthlads
Newave UPS Systems BVStephensonweg 9NL-4207 HA GorinchemTel. +31 183 64 6474Fax +31 183 62 3540
nav egy Hldig SA
Via Luserte Sud 9CH-6572 Quati
Sitzlad
Tel. +41 91 850 29 29Fax +41 91 840 12 [email protected]
nav SA
Via Luserte Sud 9CH-6572 QuartinoSwitzerland
Tel. +41 91 850 29 29Fax +41 91 840 12 [email protected]
References
Newave Certifications & Recognitions
nav Gup Cmpais
Head Office: Operations, Sales & Marketing