data_praktikum tegangan tinggi

33
KONDISI AWAL Diameter bola (D) 50 mm Temperature (t) 25 SMatas Tekanan (P) 750 mmHg 1000 mbar SMbawah Hygrometer (%) 70 Resistansi (R) 800 Mega ohm s (cm) Tegangan (kV) Ud = Tegangan tembus 1 2 3 P = tekanan (mbar) 1 20 20 20 2 36 36 36 Ud= 0,289*P/(273+T)*Udo 3 48 46 46 4 54 54 54 5 58 58 58 o C 0.5 1 1.5 2 2.5 3 3.5 0 10 20 30 40 50 60 70 Grafik Ud Vs s s (cm) Ud (KV)

Upload: arganegara-putra

Post on 16-Dec-2015

23 views

Category:

Documents


1 download

DESCRIPTION

Untuk data tegangan tinggi

TRANSCRIPT

Modul 1 D = 50 mmKONDISI AWALDiameter bola (D)50mmUdoTemperature (t)25oCSMatas0.15764mikro Faradayd= 5 cmd=10 cmTekanan (P)750mmHg1000mbarSMbawah500piko Faraday3231.7Hygrometer (%)7057.559Resistansi (R)800Mega ohm75.584s (cm)Tegangan (kV)Tegangan Rata-rata (kV)UdUdRasio88.5105Ud = Tegangan tembus1230123P = tekanan (mbar)12020202031.0321.9491.1423636363655.7639.4391.30Ud= 0,289*P/(273+T)*Udo348464646.6773.2251.7790.1345454545485.8360.6988.985585858580.0000Ud 50 = 0 karena tidak akurat lagi, karena nilai keakuratan dari pengukuran sela bola adalah 0,5 kali dari diamter sela bolanya

Modul 1 D = 100 mmKONDISI AWALHygrometer (%)70%Diameter bola (D)100mmTemperature (t)27oCTemperature (t)26oCSMatas0.15764mikro FaradayTekanan (P)760mmHg1013mbarSMbawah500piko FaradayHygrometer (%)68%Hygrometer (%)72%Resistansi (R)800Mega ohms (cm)Tegangan (kV)UCD (kV)UdoUd rmsRasioUdo123d= 5 cmd=10 cm119191919.0031.03821.94786.5713231.723838.538.538.3357.76840.84893.84357.559350545452.6782.24658.15790.56075.58446867.557.564.33102.46572.45488.79288.510557878.57878.17120.03084.87492.0970123

Modul 2;1KONDISI AWALDiameter bola (D)100mmHygrometer (%)69%Temperature (t)28oCSMatas30000piko FaradayHygrometer (%)70%Tekanan (P)750mmHg1000mbarTemperature (t)29oCHygrometer (%)68%Tekanan (P)800mmHg1066.592mbarResistansi (R)800Mega ohms (cm)Tegangan (kV)Tegangan Rata-rata (kV)UdUdRasioUdo123d= 5 cmd=10 cm126262626.0030.4421.5282.783231.7252525252.0056.6540.0677.0357.559372747473.3385.7460.6382.6775.584492929091.33100.8171.2978.0588.51055TIDAK DIHITUNG (BATAS 100 kV)0123KONDISI AWALDiameter bola (D)50mmTemperature (t)29oCSMatas30000piko FaradayTekanan (P)760mmHg1013mbarHygrometer (%)73%Resistansi (R)800Mega ohms (cm)Tegangan (kV)Tegangan Rata-rata (kV)UdUdRasio123120222221.3331.0221.9397.26242424442.6755.7439.4192.38358606059.3373.1951.7587.22464666464.6785.7960.6693.81576767876.670.000.000.00

Modul 2;2KONDISI AWALDiameter bola (D)100mmHygrometer (%)67%Tekanan (P)749mmHg998.67Temperature (t)29oCSMatas25000piko FaradayHygrometer (%)65%Tekanan (P)760mmHg1013mbarHygrometer (%)70%Resistansi (R)800Mega ohms (cm)Tegangan (kV)Tegangan Rata-rata (kV)UURasioUdo123d= 5 cmd=10 cm122242423.3330.729791059621.729243642793.12532989723231.7246484847.3357.194248344440.442440849285.441776441957.559368707270.0080.276907083156.764345371181.091921958875.584484868685.33101.786374172271.973835409584.344338370688.51055TIDAK DIHITUNG (BATAS 100 kV)0123KONDISI AWALDiameter bola (D)50mmTemperature (t)29oCSMatas30000piko FaradayTekanan (P)749mmHg996mbarHygrometer (%)65%Resistansi (R)800Mega ohms (cm)Tegangan (kV)UdrUdoUdoRasio12312222222230.5021.5798.0324848484854.8038.7580.73364626262.666666666771.9650.8881.2046868686884.3559.6587.71574727272.66666666670.000.000.00

Modul 3KONDISI AWALDiameter bola (D)100mmJARAK20mmJARAK30mmTemperature (t)29oC94 kV59,5 kVTekanan (P)750mmHg1000mbarPerbandingan5:10Perbandingan5:10Hygrometer (%)???%Tegangan (V)130kVTegangan (V)160kVResistansi (R)???Mega ohm76440kV94080kV

Modul 4A. Bola 100 - Bola 100NO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)123110202020251002692510026925100269220343434261003672610036726100367330524848261002652610026526100265440586058271002632710026327100263550686868271000602710006027100060B. Piring - PiringNO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)12311010810251001602510016025100160220303028251001622510016225100162330444246251001632510016425100165440626060251001662510016625100166550666866251000662510006625100066C. Batang - BatangNO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)123110886251000642510006425100063220101082510006325.510006325.510006333016161625.510006225.510006225.5100062440242424261000622610006226100062550302828261000622610006226100062D. Jarum - PiringNO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)12311088826.510005926.510005926.510005922016181626.510005826.510005826.510005833022222226.510005726.510005726.510005744028282827100056271000562710005655034363827999.55627999.55627999.556E. Bola 100 - PiringNO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)123110121212279995527999552799955220282828279995527999552799955330424242279995527999552799955440585656279995427999542799954550646262279995427999542799954F. Bola 100 - Bola 50NO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)12311015151227100054271000542710005422024242427100053271000532710005333052525227100053271000532710005344062626427999532799953.52799953.55507270702710005427.510005427.5100054

Modul 5A. Jarum - Jarum (Positif)A. Jarum - Jarum (Negatif)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)12312311088826100055.5811044424.5100356426100055.524.510035626100055.524.5100356220101010261000571022010101024.5100356102610005724.51003562610005724.5100356330282828261000582833018191924.510035518.66666666672610005824.51003552610005824.510035544032323226.51000583244028282824.51003552826.510005824.510035526.510005824.5100355550383838271000583855036363624.5100354362710005824.51003542710005824.5100354B. Jarum - Piring (Positif)B. Jarum - Piring (Negatif)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)1231231108882899958811012121224100460122899958241003592899958241003592202020222799958.520.66666666672202628282410035927.33333333332799958.5241003592799958.5241003583303434342799958.53433040404024100358402799958.5241003582799958.524100358440444442279995943.333333333344052525224100358522799959241003582799959241003585505050502799959505507272722410035772279995924100357279995924100357C. Piring - Piring (Positif)C. Piring - Piring (Negatif)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)123123110202018279995819.333333333311010111024.510035310.3333333333279995824.5100353279995824.51003532204242402799957.541.333333333322036363624.5100353362799957.524.51003532799957.524.510035333064646427999576433058585824.510035258279995724.5100352279995724.510035244090909027999569044079798024.510035279.3333333333279995624.51003522799955.524.51003525509696962799955.59655092929225100351922799955.5251003512799955.525100351D. Batang - Batang (Positif)D. Batang - Batang (Negatif)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)NO.Jarak (mm)Voltage Flashover (DC)T (oC)P (mbar)Hg (%)12312311014141427996.555141101616162799859162799755279985927997552799859220222422279975522.6666666667220282828279985928279975527998592799755279985933026262427.59995525.3333333333330323434279985833.333333333327.599955279985827.59995527998584403232322799855324404646462799857.54627998552799858279985527998585503636362799855365504848482799857.54827998552799857.527998552799857.5

Modul 6Tegangan Tembus pada Isolasi Tabung Gas (Bola d = 20 mm)NO.Tekanan Gas (Bar)*Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)123141080787825.510035025.510035025.5100350231066666625.510035025.510035025.5100350321052505225.510035025.510035025.5100350311030282825.510035125.510035125.5100351*note : P absolut = P gauge + 1 atm

Modul 7Tegangan Tembus pada Isolasi Minyak + Air (Piring - Piring)NO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)12312.544425.510025325.510025325.5100253Tegangan Tembus pada Isolasi Minyak + Carbon (Piring - Piring)NO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)12312.513131225.510025312.666666666725.510025325.5100253aTegangan Tembus pada Isolasi Minyak Murni (Piring - Piring)NO.Jarak (mm)Voltage Flashover (AC)T (oC)P (mbar)Hg (%)12312.520202025.510025325.510025325.5100253

Modul 8ACDCNODiameter Vcorona (V)Vfo (V)T (C)H (%)P (mbar)NODiameter Vcorona (V)Vfo (V)T (C)H (%)P (mbar)10.2951822286210102210.29526322952101032.6666666667218222862101022634295210103182229621008328322852101040.2752022295610062240.27522322952100930.6666666667520222953100652230295210096202229531009624302952100970.24522202958100821.333333333370.24520282951100928.33333333338202229581008822282951100992222295610069242929511009100.1716202953100920100.172626295210092611162029531009112626295210091216202953100812262629521009