relay sistem

47

Upload: zulfadliislami

Post on 21-Apr-2015

199 views

Category:

Documents


16 download

TRANSCRIPT

Page 1: Relay Sistem
Page 2: Relay Sistem

OCR

Ihs1

Ihs2

F1F2

RELAI ARUS LEBIH TAK BERARAH

RELAI ARUS LEBIH BERARAH

OCR

Ihs1

Ihs2F1F2

ELEMENARAH

ELEMENOCR

+

TRIPPMT

CT

PT

D

I

Page 3: Relay Sistem

APLIKASI

SALURANGANDA

SISTEM RING

INTERKONEKSI

Page 4: Relay Sistem

PRINSIP KERJA RELAI ARAH

RELAI ARAH BEKERJA BERDASARKAN PADA HUBUNGANSUDUT FASA ANTARA DUA BESARAN INPUT DARI RELAI

1. BESARAN REFERENSI [ PATOKAN ] UMUMNYA ADALAH TEGANGAN SISTEM

2. BESARAN KERJA [ OPERATING ] ADALAH ARUS .

ASAS KERJA ELEKTROMEKANIK YANG BANYAK DIGUNAKAN :

1. INDUKSI PIRINGAN [ DISK INDUCTION ]2. INDUKSI MANGKOK [ CUP INDUCTION ] .

Page 5: Relay Sistem

V

I

RELAI ARAH DENGAN MENGGUNAKANASAS DISK INDUCTION

INTERAKSI ANTARA KEDUA FLUK YAITU FLUK ARUS DAN FLUK TEGANGAN AKAN MENGHASILKAN TORSIYANG CONDONG MEMUTAR PIRINGAN ATAU MANGKOK

Page 6: Relay Sistem

I V

Iv

RELAI ARAH DENGAN MENGGUNAKAN ASAS INDUCTION CUP

Page 7: Relay Sistem

PERSAMAAN KOPEL

SinKT VI ...

Dimana :

IV

T = Torsi= Fluk kerja yang ditimbulkan oleh I= Fluk referensi yang ditimbulkan

oleh Iv= sudut antara V dan I

K = konstante

Karena sebanding dengan I , danSebanding dengan V , maka :

VI

SinIVKT ...

V

Iv

I

Vektor diagram

I

V

torsi makpositip

Torsi nol

Page 8: Relay Sistem

= Sudut relai= Sudut antara V dan I untuk

mendapatkan kopel maksimum .Bila negatip

,

Jadi :

)(...]90)[(...

)]90([...90

][...

0

0

0

CosIVKTSinIVKTSinIVKT

SinIVKT

TIPE RELAI ARAH :

00

00

00

09090/0

900

ds

SINUS

KOMBINASI

COSINUS

Page 9: Relay Sistem

V

Iv

I

I

V

torsi makpositip

Torsi nol

torsi maknegatip

P+P-

Q-

Q+

V

Positip

Negatip

TIPE KOMBINASI

Page 10: Relay Sistem

VIv

I

I

V

torsi maknegatip

P+P-

Q-

Q+

V

TIPE SINUS

torsi makPositip

00

Positip

NEGATIP

090Torsi nol

Page 11: Relay Sistem

V

Iv

I I

V

torsi makpositip

Torsi nol

torsi maknegatip P+

P-

Q-

Q+

V

Positip

Negatip

TIPE COSINUS

090

00

Page 12: Relay Sistem

1 0

&

&RL1-1Outputcircuit

Leveldetector

integrator

squarer

squarer

Phaseshift

Phaseshift

PowerSupplycircuit

21

22

27

28

13

14

1

2

+

-

RELAI ARAH STATIK / ELEKTRONIKTIPE METI 11 GEC

Iop

Vop

b ca

ABC

s1s2

Page 13: Relay Sistem

JENIS SAMBUNGAN RELAI ARAH

I. SAMBUNGAN

2 SAMBUNGAN

090030

SAMBUNGAN 090

RELAI / FASA ARUS TEGANGAN

C

B

A

III

AB

CA

BC

VVVA

B

C

Page 14: Relay Sistem

Torsi maks

045

045

A

AV

BCV

BC

AI

Torsi negatip

Vektor diagram untuk sambungan 90 dengan MTA 45

Page 15: Relay Sistem

SAMBUNGAN 30

CBA

C

B

A

III

CB

BA

AC

VVV

Relai / fasa Arus Tegangan

AV

AI A

ACV

AC

0300120

Torsi maks

Torsinol

SAMBUNGAN

MTA 00

030

Page 16: Relay Sistem

WIRING RELAI DOCR / DGFR

*

*

*

*

*

*

*

*

DOCRA

DOCRB

DOCRC DGFR

PMT

CT

PT

BUSBAR

Page 17: Relay Sistem
Page 18: Relay Sistem
Page 19: Relay Sistem

RELAI TEGANGAN

1. RELAI TEGANGAN LEBIH [ OVERVOLTAGE RELAY ]

BEKERJA BERDASARKAN KENAIKAN TEGANGANMENCAPAI / MELEBIHI NILAI SETTINGNYA .

2. RELAI TEGNGAN KURANG [ UNDER VOLTAGE RELAY ]

BEKERJA BERDASARKAN TURUNNYA TEGANGAN MENCAPAI / DIBAWAH NILAI SETTINGNYA .

Page 20: Relay Sistem

APLIKASI RELAI TEGANGAN LEBIH

1. SEBAGAI PENGAMAN GANGGUAN FASA KE TANAH[ PERGESERAN TITIK NETRAL ] PADA JARINGANYANG DISUPLI DARI TRAFO TENAGA DIMANA TITIKNETRALNYA DITANAHKAN MELALUI TAHANANTINGGI / MENGAMBANG .

2. SEBAGAI PENGAMAN GANGGUAN FASA KE TANAHSTATOR GENERATOR DIMANA TITIK NETRAL GENERATOR DI TNAHKAN LEWAT TRAFO DISTRIBUSI .

3. SEBAGAI PENGAMAN OVERSPEED PADA GENERATOR .

APLIKASI RELAI TEGANGAN KURANG

1. BERFUNGSI MENCEGAH SRATING MOTOR BILA SUPLAITEGANGAN TURUN .

2. DALAM PENGAMANAN SISTEM DAPAT DIKOMBINASIKANDENGAN RELAI FREKUENSI KURANG .

Page 21: Relay Sistem

KUMPARANLAGGING

KUMPARANUTAMA

PIRNGAN

SETTINGTRANSFORMATOR

PRINSIP KERJA RELAI TEGANGAN LEBIH

BILA TEGANGAN DIPASANG MAKA AKAN TIMBUL ARUSPADA KUMPARAN UTAMADAN BILA MANA ARUS INIMELAMPAUI HARGA TERTENTUAKAN MENGHASILAKAN TORSIPADA PIRINGAN AKAN BERPUTARSERTA MENUTUP KONTAKNYA .

1. ASAS ELEKTROMEKANIK[ INDUKSI PIRINGAN ]

Page 22: Relay Sistem

2. STATIK / ELEKTRONIK

R setting

V ref

Vin Vout

RL

PT bantu

Level detector

V

BILA Vin LEBIH BESARDARI Vref MAKA AKANMUNCUL Vout , Vout AKAN MENGERJAKAN RELAI RL ,DAN MENUTUP KONTAKNYA .

UNTUK RELAI TEGANGAN DENGAN PENUNDAAN WAKTUMAKA PADA RANGKAIN DIATAS DAPAT DITAMBAHKANRANGKAIAN TIMER .

Page 23: Relay Sistem

.

Vs X tOutputcircuit RL1

RL2Reset

OpRL1-1

RL1-2

POER SUPPLYCIRCUIT

28

27

513624

13

14

RELAI TEGANGAN LEBIHTIPE MVTD 12 GEC

Page 24: Relay Sistem

1 21,5

1000

100

10

1

Multiple of setting voltage [ X Vs ]

Opr

atin

g ti

me

[ sec

ond

]

Tms

KARAKTERISTIKWAKTU KEJA

Page 25: Relay Sistem

V Vs

Reset

Trip

1

SVV

Kt

2,5

40

51020

0,125

0,250,5

000

00

0

00

105SV

125,0TMS

RENTANG SETTINGTEGANGAN

105 S / D 187,5 VOLT

STEP = 2,5 VOLT

TMS ; ,125 S/D 1,0

STEP ; 0,125

Page 26: Relay Sistem
Page 27: Relay Sistem

.

Vs X tOutputcircuit RL1

RL2Reset

OpRL1-1

RL1-2

POER SUPPLYCIRCUIT

28

27

513624

13

14

RELAI TEGANGAN KURANGTIPE MVTD 11 GEC

Page 28: Relay Sistem

0 10,5

1000

100

10

1

Multiple of setting voltage [ X Vs ]

Opr

atin

g ti

me

[ sec

ond

]

KARAKTERISTIKWAKTU KEJA

Tms

RUMUS

Tms

VV

Kt

S

1

Page 29: Relay Sistem

PT. PLN (Persero) Kantor Pusat 1

KARAKTERISTIK OVER LOAD RELAY

DAN

BEBAN BUSUR LISTRIK

Page 30: Relay Sistem

PT. PLN (Persero) Kantor Pusat 2

PEMBATAS DAYA DENGAN RELE BEBAN LEBIH 3 FASAMEMPUNYAI KARAKTERISTIK WAKTU YANG MENGACU PADA RUMUS COLD STARTDARI KARAKTERISTIK THERMIS RELE BEBAN LEBIH

.t = x[ I ] 2

-

Dimana :

ln[ I ]2 [ k x Is]2

.t = Waktu dalam menit = konstanta thermisln = logaritma bilangan natural

I = Arus beban.k = Konstanta 1,05Is = Setelan arus rele

KARAKTERISTIK OLR

Page 31: Relay Sistem

PT. PLN (Persero) Kantor Pusat 3

NILAI DAN Is DIPILIH SEHINGGA MENDAPATKAN

KARAKTERISTIK TRIPPING SEBAGAI BERIKUT :

PADA ARUS WAKTU JATUH

1,05 x In TIDAK TRIP SEBELUM 60 MENITTRIP SEBELUM 20 MENITTRIP SEBELUM 10 MENITDIKOORDINASIKAN DENGAN PENGAMAN HUBUNG SINGKAT(OCR)

1,20 x In1,50 x In4,00 x In

KHUSUS PELANGGAN TANUR LISTRIK In = 115% x DAYA KONTRAK

In = DAYA KONTRAK

Page 32: Relay Sistem

PT. PLN (Persero) Kantor Pusat 4

Rele buatan GEC Measurement type MCHNO2

Parameter setelan Rele:1. Setelan Arus beban penuh = Is2. Setelan kurva pemanasan dan pendinginan = 3. Setelan Arus terkecil dimana Rele bisa trip = I1 = 1,05xIn4. Setelan time constant = 5. Arus yang masuk ke Rele = I

.t = x[ I ] 2

ln[ I ]2 [ k x Is]2

Pembatas TDL: 2001 menit Pembatas TDL 20001,05xIn = 1,06xIs 1,05 62,82 1,05xIn > 60 menit1,20xIn = 1,21xIs 1,20 19,16 1,20xIn < 20 menit1,50xIn = 1,51xIs 1,50 8,96 1,50xIn < 5 menit4,00xIn = 4,02xIs 4,00 0,95 4,00xIn 5 detik

Ibeban = 1 AmpIs = 0,99524 Amp = 13,49 menitk = 1,05

Diperoleh :

Page 33: Relay Sistem

PT. PLN (Persero) Kantor Pusat 5

PENGUKURAN BEBAN TERTINGGI (PELANGGAN I-3 TANUR)KARENA PEMBATAS DAYANYA DI SET 115% x DAYA KONTRAKBEBAN TERTINGGI DIUKUR DENGAN :• KVA MAX

• KW MAXINTERVAL 15 MENIT

BILA MENGGUNAKAN KW MAX KVA MAX = KW BACA / COS

BEA BEBAN BERDASARKAN KVA TERTINGGI YANG TERCATATDI KVA MAKSKVA TERTINGGI KVA KONTRAK BEA BEBAN BERDASARKAN

KVA KONTRAKKVA TERTINGGI 110% KVA KONTRAK BUAT ADDENDUM KONTRAK

COS = FAKTOR DAYA DIBULAN PEMAKAIAN

PENGUKURAN KWh DAN KVARh DENGAN METER TARIF TUNGGALMETER ELEKTROMEKANIS BERTAHAP DIGANTI ELEKTRONIK

PENGUKURAN kVArh

Page 34: Relay Sistem

PT. PLN (Persero) Kantor Pusat 6

BATASAN KEDIP TEGANGANAKIBAT GANGGUAN HUBUNG SINGKAT : TEGANGAN TURUN

SESAAT (KEDIP).TIDAK BISA DITETAPKAN TURUNNYA TEGANGAN :

KARENA TERGANTUNGLOKASI GANGGUANLAMANYA KEDIP : TERGANTUNG WAKTU

KERJA RELE PROTEKSI

BATASAN ‘ KEDIP TEGANGAN ’ DI SISTEM PLN OLEH RELE UTAMA

TEGANGAN SISTEM LAMA KEDIP (mDet.)

JARINGAN TEGANGAN EHV 500 kV 110JARINGAN TEGANGAN TINGGI 150 kV 140JARINGAN TEGANGAN TINGGI 70 kV 170JARINGAN TEGANGAN TENGAH 20 kV 1000 (1 det)

BATAS KEDIP TEGANGAN

Page 35: Relay Sistem

PT. PLN (Persero) Kantor Pusat 7

TEGANGAN SISTEM LAMA KEDIP (mDet.)

JARINGAN TEGANGAN EHV 500 kV 500 (0,5 det)JARINGAN TEGANGAN TINGGI 150 kV 500 (0,5 det)JARINGAN TEGANGAN TINGGI 70 kV 500 (0,5 det)

BATASAN ‘ KEDIP TEGANGAN ’ DI SISTEM PLN OLEH RELE CADANGAN

BATAS KEDIP TEGANGAN

Page 36: Relay Sistem

PT. PLN (Persero) Kantor Pusat 8

PELANGGAN TANUR BUSUR LISTRIKBEBAN TANUR BUSUR LISTRIK PENYEBAB :• KELIP TEGANGAN (VOLTAGE FLICKER)• FAKTOR KETIDAK SEIMBANGAN TEGANGAN/ARUS• HARMONISA TEGANGAN• GONCANGAN FREKWENSI

KELIP TEGANGAN = KEDIP TEGANGAN YANG BERULANG-ULANG

PERSYARATAN KELIP TEGANGAN ATAU DEPRESI TEGANGAN HUBUNG SINGKAT (DTHS) DIBATASI SBB:

TEGANGAN SISTEM DTHS

JARINGAN TEGANGAN TINGGI 150 kV 2,5 %JARINGAN TEGANGAN TINGGI 70 kV 2,75 %

BATAS KELIP TEGANGAN

Page 37: Relay Sistem

PT. PLN (Persero) Kantor Pusat 9

PELANGGAN YANG TIDAK MEMENUHI SYARAT DTHS DIATAS HARUS PASANG KOMPENSATOR

FAKTOR KETIDAK SEIMBANGAN TEGANGAN:•RASIO KOMPONEN NEGATIF TERHADAP KOMPONEN POSITIFDITITIK SAMBUNG BERSAMA TIDAK LEBIH DARI 2 %

•TEGANGAN HARMONIS DI JARINGAN 20 kV KEATASLEBIH KECIL 3 %•GONCANGAN FREKWENSI MENYESUAIKAN KETETAPAN PLN SETEMPAT (KAPASITAS TANUR TERBATAS) MENURUT KAPASITAS PEMBANGKITAN, BILA DI LANGGAR PLN BERHAKMELAKUKAN PEMUTUSAN

PERSYARATAN DTHS

Page 38: Relay Sistem

PT. PLN (Persero) Kantor Pusat 10

KARAKTERISTIK OVER CURRENT RELAY

PENGETAHUAN TENTANG PEMBATAS TIDAK MENGGUNAKAN RELE OVER CURRENT

KARENA : DAPAT DIMANIPULASI KONSUMEN PENARIKANDAYA DAYA YANG DI KONTRAK

Iset

15 30 menit

Amper

0

RELERESET RELE

PICKUPRELERESET

PEMAKAIAN DIATAS 110% DAYA KONTRAK

RELEPICKUP

Page 39: Relay Sistem

PT. PLN (Persero) Kantor Pusat 11

OVER LOAD RELAY

PENGETAHUAN TENTANG PEMBATAS MENGGUNAKAN RELE OVER LOAD

menit0 15 30

Temp

Ttrip

BEBANNORMAL

PEMAKAIAN DIATAS 110% DAYA KONTRAK

PEMBATAS TRIP

Page 40: Relay Sistem

PT. PLN (Persero) Kantor Pusat 12

TERIMA KASIH

Page 41: Relay Sistem
Page 42: Relay Sistem

RELAI FREKUENSI

BESARAN INPUT DARI RELAI FREKUENSI ADALAHTEGANGAN YANG DIAMBIL DARI TRAFO TEGANGAN [ PT ]

RELAI INI MEMONITOR BESARNYA FREKUENSI SISTEM .

1. RELAI FREKUEN SI KURANG [ UFR ]

MEMBANDINGKAN FREKUENSI SISTEM DENGANFREKUENSI SETTINGNYA .BILA FREKUENSI SISTEM LEBIH KECIL ATAUSAMA DENGAN FREKUENSI SETTING MAKA RELAI AKAN KERJA

2. RELAI FREKUENSI LEBIH

BILA FREKUENSI SISTEM LEBIH BEAR ATAUSAMA DENGAN FREKUENSI SETTING MAKARELAI AKAN KERJA .

Page 43: Relay Sistem

FUNGSI / APLIKASI UFR

1. DIPASANG PADA PENYULANG TM , UNTUKLOAD SHEDDING SECARA OTOMATIS BILATERJADI PENURUNAN FREKUENSI SIATEM ,AKIBAT KEHILANGAN DAYA PEMBANGKIT .ADA 6 TAHAP PENYETELAN RELAI UFR DI PENYULANG 20 KV PLN YAITU 48,8 – 48,2 Hz

2. DIPASANG DI PEMBANGKIT ,UNTUK MEMISAHKAN PEMBANGKIT DARI SISTEM INTERKONEKSI, BILA TERJADI GANGGUAN PADA SISTEM [ ISLANDING SYSTEM ]DILENGKAPI DENGAN UVR .

FUNGSI / APLIKASI OFR

DIPASANG DI PEMBANGKIT SEBAGAIPENGAMAN KECPATAN LEBIH [ OVERSPEED ]

Page 44: Relay Sistem

R1

R2

C

f

f

Prinsip kerja

Relai frekuensi dengan asas induksi

Page 45: Relay Sistem

T1

T2

T1

T2

T T1

T T2

1

2

T1

T2

VV

Page 46: Relay Sistem

sec.0.0.0.0.0.0T1 Hz

T1f

11

MFVU

sec.0.0.0.0.0.0T2 Hz2

2 T1f

0,050.10,20,20,5

1225

10

0000000000

0.050,10,20,20,5

1225

10

0000000000

f1 f1

f2f2f1 ON OFF

ON OFFPu:do

1:1f2:f1

Vx=110V=

MFVU210CA00045

f1 f2 Reset Test

sec)1,0(

t2

sec)1,0(

t1

Page 47: Relay Sistem

V=

52TC 52TC

52a52a

110V+

-

27

28

13 +14

PT

BUS 20 KV

1

3

9

11

MFVU

TRIP PMT 1

TRIP PMT 2

t1

t2

f1

f2

PT

PENGAWATAN