piping & pipeline

51

Upload: dicky-pratama

Post on 27-Jan-2016

252 views

Category:

Documents


24 download

DESCRIPTION

nambah ilmu

TRANSCRIPT

Page 1: Piping & Pipeline
Page 3: Piping & Pipeline

PIPING & PIPELINES

PIPA MERUPAKAN KOMPONEN YANG VITAL DIDALAM INDUSTRI MIGAS, UNTUK MENYALURKAN FLUIDA

MULAI DARI WELL SAMPAI KE TANKER BAHKAN SAMPAI KE PONT TERAKHIR KONSUMEN.

DEFINISI MACAM2 PIPA SESUAI DENGAN KEGUNAANNYA:

1. TUBING PIPA YANG DIPASANG DIDALAM SUMUR, UNTUK MENYALURKAN MINYAK DARI FORMATIN

KE SURFACE

2. CASING PIPA BESAR YANG DIPASANG UNTUK MELINDUNGI SUMUR DAN TUBING DARI LAPISAN BUMI

3. FLOW LINE PIPA UNTUK MENYALURKAN FLUIDA DARI WELL HEAD KE MANIFOLD

4. MANIFOLD ADALAH KUMPULAN FLOW LINE DARI WELL DAN DISUSUN SEDEMIKIAN RUPA SEHINGGA ALIRAN DARI SUMUR BISA DIALIRKAN KE TEST SEPARATOR DAN BISA JUGA KE

PRODUCTION LINE

5. PROD. HEADER ADALAH PIPA UTAMA DI MANIFOLD YANG MENGALIRKAN MINYAK DARI WELL KE PRODUCTION LINE

6. PIPELINE PIPA UTAMA YANG MENGALIRKAN TOTAL PRODUKSI DARI PLATFORM KE PLATFORM, DARI PLATFORM KE GATHERING STATION, DARI GATHERING STATION KE STORAGE TANK

Page 4: Piping & Pipeline

PENGETAHUAN DASAR PERPIPAAN

A. CARBON STEEL PIPEPIPA DI INDUSTRI MIGAS BIASANYA MENGGUNAKAN PIPA BAJA KARBON ATAU

CARBON

STEEL PIPE.PIPA BAJA INI

MEMILIKI KEKUATAN YANG TINGGI, KENYAL, DAPAT DILAS DAN TAHAN LAMA

KELEMAHANNYA ADALAH TIDAK TAHAN TERHADAP SERANGAN KOROSI ( H2SO4 )

CARBONATE ( KSO3 ) DAN AIR LAUT.

KARENA ITU UNTUK PIPA YANG DIPASANG DIBAWAH LAUT MAUPUN DALAM TANAH AKAN MENGGUNAKAN

PROTEKSI KHUSUS AGAR TIDAKDISERANG ZAT YANG KOROSIF, MISALNYA:

1. PIPA YANG DIPASANG DIBAWAH LAUT DIBERI LAPISAN KHUSUS ( COATING ) SEMACAM SEMAN,

SEHINGGA BISA BERTAHAN LAMA.

2. PIPA YANG DITANAM DIDALAM TANAH BIASANYA DILAPISI DENGAN SEMACAM TAPE KHUSUS

SERING JUGA KITA MELIHAT PIPA DIPASANG DENGAN KATODA & ANODA

A. CARBON STEEL PIPEB. STAINLESS STEEL

PIPEC. CAST IROND. GALVANIZED PIPE

BERMACAM MACAM PIPA DAN KEGUNAANNYA

Page 5: Piping & Pipeline

PENGETAHUAN DASAR PERPIPAAN

PIPA BAJA KARBON DIGUNAKAN UNTUK BERBAGAI KEPERLUAN,

DIANTARANYA:

JARINGA PIPA MINYAK ( CRUDE, BBM )

JARINGAN PIPA GAS

JARINGA PIPA AIR

JARINGAN PIPA ANGIN

JARINGAN PIPA STEAM

Page 6: Piping & Pipeline

B. PIPA BAJA – STAINLESS STEEL PIPE

PIPA JENIS INI MEMPUNYAI SIFAT TAHAN TERHADAP OKSIDASI DAN ZAT YANG KOROSIF

UNTUK FASILITAS LNG JENIS PIPA INI DIPAKAI PADA CO2 – REMOVAL UNIT, UNTUK

MANYALURKAN CARBONATE, DAN UNTUK FLARE STACK.

STAILESS STEEL PIPE MEMILIKI THERMAL STRENGTH YANG TINGI ( 1,5 X CARBON STEEL )

C. PIPA BESI TUANG ( CAST IRON )

PIPA BESI TUANG GOLONGAN KELAS YANG TAHAN AKAN KOROSI

BESI TUANG MEMILIKI KEKERASAN TINGGI TETAPI MEMILIKI KERAPUHAN YANG TINGGI PULA

BESI TUANG TIDAK BAIK DIPAKAI UNTUK FASILITAS YANG MEMILIKI KONTRAKSI DAN GETARAN TINGGI

Page 7: Piping & Pipeline

D. PIPA GALVANIZED

PIPA JENIS INI ADALAH JENIS CARBON STEEL NAMUN BAGIAN LUAR DAN DALAM

PIPA DILAPISI DENGAN SENG.

AGAR TAHAN TERHADAP KARAT, BIASANYA DIGUNAKAN UNTUK SALURAN AIR

DAN CONDUIT / PIPA UNTUK PROTEKSI KABEL LISTRIK

Page 8: Piping & Pipeline

STANDARD PIPE

PIPA DIGUNAKAN BERMACAM MACAM KEPERLUAN DAN UKURAN SERTA KEKUATAN YANG BERBEDA BEDA.

UNTUK MENENTUKAN KESERAGAMAN AGAR SESUAI DENGAN KEGUNAANNYA MAKA DIBUATLAH STANDARISASI

INTERNASIONAL

STANDARISASI INTERNASIONAL MELIPUTI

1. STANDARD UKURAN

2. STANDARD PANJANG

3. STANDARD BAHAN

Page 9: Piping & Pipeline

STANDARISASI INTERNASIONAL MELIPUTI1. STANDARD UKURAN

2. STANDARD PANJANG

3. STANDARD BAHAN

STANDARD UKURAN:

STANDARD UKURAN DIAMETER PIPA

a. DIAMETER DALAM ( ID = INSIDE DIAMETER )

b. DIAMETER LUAR ( OD = OUTSIDE DIAMETER )

c. DIAMETER NOMINAL ( NPS = NOMINAL PIPE SIZE )

Page 10: Piping & Pipeline

MENURUT ANSI ( American National Standard Institute ) dan

ASME ( American Society of Mechanical Engineer ),

UKURAN DIAMETER PIPA DITENTUKAN SEBAGAI BERIKUT:

a. UNTUK UKURAN PIPA 1/8 “ – 12 “ NOMINAL DIAMETER PIPA TIDAK SAMA DENGAN DIAMETER LUARNYA, YANG DIUKUR ADALAH ID ATAU INSIDE DIAMETER

b. UNTUK UKURAN PIPA >12 “ – 24 “ NOMINAL DIAMETER SAMA DENGAN OD ( OUTSIDE DIAMETER )

Nominal = OD

1/8 “ – 12 “

Nominal = OD

>12 “ – 24 “

Page 11: Piping & Pipeline

PIPPING - SCHEDULE UNTUK PIPA YANG MEMILIKI OD – OUTSIDE DIAMETER SAMA , NAMUN BISA

MEMILIKI TEBAL DINDING YANG BERBEDA BEDA SESUAI DENGAN SCHEDULE NUMBERNYA

OD = 2.375 “

2 “

ID = 2.067 “

Schedule - 40

2 “

OD = 2.375 “

ID = 1.939 “

Schedule - 80

2 “

OD = 2.375 “

ID = 1.689 “

Schedule - 160

Page 12: Piping & Pipeline

UKURAN PANJANG PIPA

ADA BERMACAM MACAM UKURAN PANJANG PIPA SESUAI DENGAN

ISTILAH TEKNISNYA:

1. UNIFORM LENGTH PANJANG = 21 FT.

2. NORMAL LENGTH PANJANG = 12 FT.

3. CUT LENGTH PANJANG SESUAI DENGAN PERMINTAAN

CARA PEMBACAANDARI CONTOH GAMBAR - TERDAPAT KESIMPULAN

1. DIAMETER LUAR ( OD ) TIDAK BERUBAH

2. DIAMETER DALAM ( ID ) SESUAI DENGAN YANG SEBENARNYA

- SCHEDULE 40 ACTUAL ID = 2.067 “

- SCHEDULE 80 ACTUAL ID = 1. 039 “

- SCHEDULE 160 ACTUAL ID = 1.689 “

UNTUK MUDAHNYA BISA DILIHAT DI TABEL PIPA MENURUT API DAN SHEDULE ASA

Page 13: Piping & Pipeline

STANDARD TEBAL DINDING

( WALL THICKNESS )ADA 2 ( DUA ) STANDARD TEBAL DINDING PIPA BAJA KARBON

1. ANSI B.36.10 WELDED AND SEAMLESS WROUGHT STEEL PIPE

2. ANSI B. 36.19 STAINLESS STEEL PIPE

ALL PIPING SYSTEM SHALL BE DESIGNED, INSTALLED DAN TESTING IN

ACCORDANCE WITH THE APPROPRIATE ANSI B31 CODE, AS FOLLOWS:

a. ANSI B31.1 POWER PIPING

b. ANSI B31.2 FUEL GAS PIPING

c. ANSI B31.3 CHEMICAL PLANT AND PETROLEUM REFINERY PIPING

d. ANSI B31.4 LIQUID PETROLEUM TRANSPORTATION PIPING SYSTEM

e. ANSI B31.5 REFRIGERATION PIPING

f. ANSI B31.8 GAS TRANSMISSION AND DISTRIBUTION PIPING SYSTEM

g. ANSI B31.9 BUILDING SERVICES PIPING

Page 14: Piping & Pipeline

STANDARD TEBAL DINDING

( WALL THICKNESS )ADA 2 ( DUA ) STANDARD TEBAL DINDING PIPA BAJA KARBON

1. ANSI B.36.10 WELDED AND SEAMLESS WROUGHT STEEL PIPE

2. ANSI B. 36.19 -> STEEL PIPE SCHEDULE NUMBER

1. ANSI B.36.10

STEEL PIPE WALL THICKNESS DESIGNATION

TERBAGI MENJADI 3( TIGA ) GOLONGAN:

a. STANDARD WEIGHT ( STD )

TEBAK DINDING NORMAL UNTUK PIPA BERTEKANAN 150 PSI

B. EXTRA STRONG – ES / EXTRA HEAVY – EH

DINDING LEBIH TEBAL UNTUK PIPA BERTEKANAN 300 PSI

c. DOUBLE EXTRA STRONG ( XXS ATAU XXH )

PIPA XXS ATAU XXH TEBAL DINDINGMYA 2 X HS / XH

DIGUNAKAN UNTUK PIPA BERTEKANAN DIATAS 600 PSI

2. ANSI B.36.10

STEEL PIPE - SCHEDULE NUMBER

STANDARD INI LEBIH FAMILIAR DI INDUSTRY MIGAS

PENGELOMPOKANNYA DISAMPING PRESSURE , TEMPERATURE JUGA DICANTUMKAN

ADA 10 STANDARDS SEBAGAI BERIKUT :

SCHEDULE, 10,20,30,40,60,80,100,1120,140,160

SPEC BISA DILIHAT DI TABEL

Page 15: Piping & Pipeline

MATERIAL STANDARD

STANDAR BAHAN YANG DIPAKAI BIASANYA MEMAKAI STANDARD AMERIKA, YAITU YANG DIKENAL DENGAN NAMA :

• ASTM AMERICAN SOCIETY FOR TESTING MATERIAL

• API AMERICAN PETROLEUM INSTITUTE

• ANSI AMERICAN NATIONAL STANDARD INSTITUTE

STANDARD BENTUK PIPA BERDASARKAN UJUNGNYA

• PLAIN END SAMBUNGAN PIPA DENGAN SOCKET WELDING

• THREADED END SISTIM SAMBUNGAN PIPA BERULIR

• BEVELED END SISTIM SAMBUNGAN BUTT WELDING

STANDARD – PIPE END

Page 16: Piping & Pipeline

1. PIPA BAJA KARBON ( CARBON STEEL PIPE )

a. ASTM - A. 53 ( GRADE A AND B )

b. ASTM – A. 106 ( GRADE A, B, C )

c. ASTM – A. 155

d. API GRADE A,B MAUPUN GRADE X – 42

2. PIPA BAJA STAINLESS ( STAINLESS STEEL PIPE )

a. ASTM – A. 132 TYPE 304 ( AISI 304 )

b. ASTM – A 312 TYPE 321 ( NANSI 321 )

c. ASTM – A 358 TYPE 321 ( AISI 321 )

MATERIAL STANDARD

3. PIPA BAJA TUANG ( CAST IRON )

ANSI – A. 211

4. PIPA LAPISAN SENG ( GALVANIZED PIPE )

a. ASTM - A. 53 GALVANIZED

b. ASTM – A. 120 GALVANIZED

MATERIAL STANDARD

Page 17: Piping & Pipeline

WELL HEAD PRESSURE2500 PSIG

WELL HEAD PRESSURE2500 PSIG

PROCESSING PLANT

API 3000 PSI ANSI 1500 ANSI 600 ANSI 300 ANSI 150

GAS OUTLET

GAS OUTLET

GAS OUTLET

Z

MANIFOLDWELL HEAD

TO OTHER SYSTEM

TO STRORAGE

HIGH – P SEPARATO

R

MEDIUM – P

SEPARATOR

LOW – P SEPARATO

R

EXAMPLE PROCESS SYSTEM

SYSTEM DESIGN PRESSURE

1420 PSIG

500 PSIG 125 PSIG

APPLICABLE FLANGE & VALVE PRESSURE

RATING CLASSIFICATION

Page 19: Piping & Pipeline
Page 20: Piping & Pipeline

PIPE SIZING

GAS PIPING

LIQUID PIPING

COMPRESSOR PIPING

PUMP PIPING

Page 21: Piping & Pipeline

PRESSURE DROP IN GAS PIPING

DESCRIPTION FORMULA

PRESSURE DROP = ( MMCFD )2 X ( Sp.Gr ) X ( Temp. + 460 ) x ( Ft. ) x ( C2 )

( 2.67 ) x ( PSIA )

MMCFD = Million Standard Cubic Feet Per Day

Sp. Gr. = Specific Gravity of the Gas

TEMP. = Temperature of Gas in O F

Ft = Length of pipe in Feet

PSIA = ( Gauge pressure + 14.7 )

C2 = Constant from table

Page 22: Piping & Pipeline

LINE SIZE FOR GAS PIPING

DESCRIPTION FORMULA

( 50 ) X ( Psia ) ( MMCFD )2 X ( Sp.Gr ) X ( Temp. + 460 )

( 50 ) X ( Psia ) ( MMCFD )2 X ( Sp.Gr ) X ( Temp. + 460 )

( 50 ) X ( Psia ) ( MMCFD )2 X ( Sp.Gr ) X ( Temp. + 460 )

C2 =

C2 =

C2 =

FOR 0 – 100 PSIG

FOR 100 – 500 PSIG

FOR 500 – 1000 PSIG

SELECT PIPE SIZE FROM TABLE – 1 THAT

HAS A C2 LESS THAN OR EQUAL TO THE C2 CALCULATED ABOVE

Page 23: Piping & Pipeline

LINE SIZING TO AND FROM COMPRESSORS

DESCRIPTION FORMULA

UP TO 50 PSIAID = 1 X ( MMCFD) X ( Temp. + 460 ) ( psia )

50 – 250 PSIAID = (1.06)X ( MMCFD) X ( Temp. + 460 ) ( psia )

Over 250 PSIAID = (1.19)X ( MMCFD) X ( Temp. + 460 ) ( psia )

REMARKS

V

V

V

ID = Internal Diameter Of Pipe

MMCFD = Million Standard Cubic Feet Per Day

TEMP. = Temperature of Gas in O F

PSIA = ( Gauge pressure + 14.7 )

Page 24: Piping & Pipeline

LIQUID PIPING TO AND FROM PUMP

RECIPROCATING PUMPS

SUCTION DISCHARGE

SPEED UP TO 250 RPM ID = 0.4 X GPMID = 0.25 X GPM

SPEEDS BETWEEN 250 – 330 RPM

ID = 0.5 X GPMID = 0.30 X GPM

SPEED ABOVE 330 RPM ID = 0.6 X GPMID = 0.35 X GPM

CENTRIFUGAL PUMPS SUCTION DISCHARGE

ID = 0.35 X GPM

ID = 0.25 X GPM

V V

V

V

V

V

V

V

REMARKS :

ID = INTERNAL DIAMETER OF PIPE

GPM = GALLON PER MINUTE OF LUQUID FLOW

Page 25: Piping & Pipeline
Page 26: Piping & Pipeline
Page 27: Piping & Pipeline
Page 28: Piping & Pipeline
Page 29: Piping & Pipeline
Page 30: Piping & Pipeline
Page 31: Piping & Pipeline
Page 32: Piping & Pipeline

@20Set @

50 Psig

Set @ 20 Psig

Page 33: Piping & Pipeline
Page 34: Piping & Pipeline

COUPLINGBERFUNGSI SEBAGAI PENYABUNG PIPA DENGAN PIPA YANG BERDIAMETER SAMA.

CARA PEMASANGAN DENGAN MENGGUNAKAN THREAD AND SOCKET

NIPPLENIPPLE ADALAH PIPA PENDEK YAMG DIGUNAKAN UNTUK MENYAMUNG DUA FEMALE –

THREAD FITTING YANG SAMA DIAMETERNYA.BEBERAPA MACAM NIPPLE:

HEXAGON EQUAL NIPPLE

HEXAGON REDUCING NIPPLE

WELDING NIPPLE BARREL NIPPLE

Page 35: Piping & Pipeline

ELBOW CONNECTIONBEBERAPA TIPE ELBOW YANG SERING

DIGUNAKAN DI INDUSTRI MIGAS

45 O WELDED ELBOW

45 O THREADED ELBOW

45 O STEET ELBOW

90 O WELDED ELBOW

90 O THREADED ELBOW

90 O STEET ELBOW

Page 36: Piping & Pipeline

TEE FITTINGBEBERAPA TIPE TEE – FITTING YANG

SERING DIGUNAKAN DI INDUSTRI MIGAS:

WELDED STRAIGHT TEE

WELDED REDUCING TEE

THREADED STRAIGHT TEE

THREADED REDUCING TEE

Page 37: Piping & Pipeline

PLUGPLUG DIGUNAKAN UNTUK MENUTUP / MENYUMBAT FEMALE THREAD FITTING.

BEBERAPA JENIS PLUG DIANTARANYA:

HEXAGON HEAD PLUG

SQUARE HEAD PLUG

BULL PLUG

HEXAGON HEAD PLUG SQUARE HEAD PLUG BULL PLUG

Page 38: Piping & Pipeline

RETURN BEND180 O RETURN BEND DIGUNAKAN UNTUK MENGHUBUNGKAN PIPA

DENGAN TUJUAN SEBAGAI PENGUBAH ARAH ALIRAN DENGAN MEMBELOKKAN 180O.

BEBERAPA TIPE RETURN BEND SEBAGAI BERIKUT:

180 O RETURN BEND – LONG RADIUS

180 O RETURN BEND – SHORT RADIUS

180O RETURN BEND – LONG RADIUS 180O RETURN BEND – SHORT RADIUS

Page 39: Piping & Pipeline

CAPADA LAGI TIPE PENUTUP TETAPI BUKAN – PLUG KITA SEBUT CAP, ADA TIPE WELDED ADA JUGA TIPE THREADED

LATERALLATERAL FUNGSINYA SAMA DENGAN “ TEE “, TETAPI SALURAN KELUARNYA

MEMBENTUK SUDUT 45 O, TERHADAP PIPA INDUKNYA. JENISNYA ADA DUA

MACAM YAITU ( THREADED & WELDED LATERAL )

1. LATERAL DAN REDUCING LATERAL

2. REDUCING LATERAL MEMPUNYAI DIAMETER SALURAN KELUAR YANG LEBIH KECIL DARIPADA SALURAN UTAMA

THREADED CAP WELDED CAP

THREADED LATERAL WELDED LATERAL

Page 40: Piping & Pipeline

UNIONUNION DIGUNAKAN UNTUK MEMUDAHKAN MENYAMBUNG DAN

MELEPASKAN

SAMBUNGAN MELALUI THREAD TANPA MEMUTAR BAGIAN PIPA YANG PANJANG.

SATU UNIT – UNION TERDIRI DARI SATU – UNION RING DAN DUA – SLEEVE

1. STANDARD UNION

2. HAMMER UNION

STANDAR UNION HAMMER UNION

UNION - RING

SLEEVE

SLEEVE

Page 41: Piping & Pipeline

REDUCER FITTING1. REDUCING COUPLING – KEDUA UJUNGNYA MEMPUNYAI FEMALE

THREAD TYPE

2. SWAGE – KEDUA UJUNGNYA MEMPUNYAI – MALE THREAD TYPE

3. BUSHING – KEDUA UJUNGNYA MEMPUNYAI ULIR YANG BERBEDA

YAITU FEMALE THREAD TYPE DAN MALE THREAD TYPE

REDUCING COUPLING SWAGE BUSHING

Page 42: Piping & Pipeline

REDUCER FITTING1. TYPE CONCENTRIC REDUCER

MEMILIKI CENTER LINE YANG SAMA DARI DIAMETER BESAR KE DIAMETER YANG KECIL . UMUMNYA DIGUNAKAN PENYAMBUNGAN PADA PIPA VERTIKAL

2. EXENTRIC REDUCER

MEMILIKI CENTER LINE YANG TIDAK TERLETAK SIMETRIS DARI DIAMETER BESAR KE DIAMETER YANG KECIL.

UMUMNYA DIGUNAKAN UNTUK MENYAMBUNG DUA PIPA YANG MEMILIKI DIAMETER BERBEDA’

CONCENTRIC REDUCER

EXCENTRIC REDUCER

Page 43: Piping & Pipeline
Page 44: Piping & Pipeline

VALVE

ISTRUMENTATION ADALAH RANGKAIAN PERALATAN YANG DIGUNAKAN UNTUK MEMBANTU OPERATOR DIDALAM MENGONTROL “ PROSES

PERMINYAKAN “ SEHINGGA OPERATOR TIDAK PERLU BEKERJA SECARA MANUAL TERUS MENERUS.

SALAH SATU DIANTARANYA ADALAH VALVE ATAU KERANGAN.

BERDASARKAN FUNGSINYA VALVE DAPAT DIGOLONGKAN SEBAGAI BERIKUT :

1. ISOLATOR BLOCKING

2. KONTROL REGULATING

3. PENCEGAHAN ARUS BALIK BACK FLOW

4. MEMBUANG OVER PRESSURE PRESSURE RELIEF

Page 45: Piping & Pipeline

VALVE :

ADA BERMACAM MACAM VALVE DAN MASING – MASING MEMILIKI

KEGUNAAN YANG BERBEDA BERDASARKAN TEKANAN DAN

TEMPERATUR FLUIDA YANG AKAN MENGALIR MELALUI VALVE

TERSEBUT

1. GATE VALVE2. GLOBE VALVE BALL VALVE3. BUTTERFLY VALVE4. CHECK VALVE5. PRESSURE RELIEF VALVE

BEBERAPA GOLONGAN BESAR VALVE

Page 46: Piping & Pipeline

1. GATE VALVE2. GLOBE VALVE BALL VALVE3. BUTTERFLY VALVE4. CHECK VALVE5. PRESSURE RELIEF VALVE

FUNGSI & CARA KERJA BERMACAM VALVE

1. GATE VALVE

VALVE JENIS INI DIGUNAKAN UNTUK MENGONTOL CAIRAN YANG MENGALIR PADA PIPA. KOMPONEN UTAMANYA ADALAH SEBUAH CAKRAM ( DISC / GATE ), UNTUK MEMBUKA MENUTUP ALIRAN FLUIDA TEGAK LURUS. MAKA VALVE JENIS INI TIDAK SESUAI UNTUK APLIKASI KONTROL

VALVE INI BAIK UNTUK BLOCKING ( MEMBUKA ATAU MENUTUP ) SAJA SECARA PENUH DAN TIDAK BAGUS UNTUK MENJEPIT / THROTTLING, KARENA APABILA DIGUNAKAN UNTUK MENJEPIT MAKA ALIRAN AKAN MENJADI TURBULEN DAN TENDENSI UNTUK MENGIKIS GATENYA.

BIASANYA DIOPERASIKAN SECARA MANUAL.

Page 47: Piping & Pipeline

2. GLOBE VALVE

BENTUKNYA BUNDAR, KOMPONEN UTAMA SEBUAH GLOBE VALVE ADALAH PLUG & CAGE.

KEDUDUKAN PLUG DIDALAM CEGE PARALLEL DENGAN ARAH ALIRAN FLUIDA, SEHINGGA VALVE INI BAIK UNTUK “ THROTTLING “ DENGAN TENDENSI PENGIKISAN YANG MINIMAL.

PERAWATANNYA LEBIH MUDAH BAHKAN GLOBE VALVE DAPAT DIPERBAIKI TANPA MELEPAS KESELURUHAN BODY.

3. BALL VALVE

KOMPONEN UTAMANYA ADALAH SEBUAH BOLA DENGAN POTONGAN “ V – BALL “

BEKERJANYA DENGAN ¼ PUTARAN UNTUK MEMBUKA ATAU MENUTUP SECARA PENUH. SANGAT SEDIKIT PENGARUH TERHADAP TURBULENSI DAN BAIK UNTUK DIOPERASIKAN SECARA OTOMATIS ATAU MANUAL.

Page 48: Piping & Pipeline

4. BUTTERFLY VALVE

TERDIRI DARI SEBUAH CAKRAM YANG BERPUTAR ¼ PUTARAN UNTUK MENGATUR ALIRAN FLUIDA. KELEBIHAN UTAMANYA ADALAH KETAHANAN MENAHAN KEBOCORAN ( SHUT OFF ) SESUAI DENGAN KONSTRUKSINYA CAKRAM AKAN MENUTUP RAPAT TERHADAP LINER DISEKELILING BODY VALVE. BAIK UNTUK THROTTLING DAN ON / OFF CONTROL VALVE

Page 49: Piping & Pipeline

5 PLUG VALVE

PLUG VALVE DIGUNAKAN UNTUK NGEBLOK / MENUTUP SUATU ALIRAN DENGAN WAKTU YANG RELATIF LAMA DAN BERTEKANAN TINGI

5 CHECK VALVE

SESUAI NAMANYA CHECK VALVE AKAN BERFUNGSI MENJAGA KE SATU ARAH ALIRAN DAN AKAN MENUTUP BILA ALIRAN BERLAWANAN ARAH / BACK FLOW.

ADA TIGA JENIS CHECK VALVE YAITU ( SWING / FLIPPER, LIFT / PISTON DAN BALL / STOP

Page 50: Piping & Pipeline

CRUDE OIL TRUNKLINE

Page 51: Piping & Pipeline

CRUDE OIL TRUNKLINE