PERENCANAAN ULANG INSTALASI POMPA PENYALUR BASE OIL DI PT PERTAMINA PRODUCTION UNIT GRESIK Putra Aditiawan 2108030043 Dosen pembinmbing: Dr.Ir.Heru Mirmanto,MT TUGAS AKHIR KONVERSI ENERGI

Upload: vunhu

Post on 11-Mar-2018

283 views

Category:

Documents


17 download

TRANSCRIPT

Page 1: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

PERENCANAAN ULANG INSTALASI

POMPA PENYALUR BASE OIL DI PT

PERTAMINA PRODUCTION UNIT

GRESIK

Putra Aditiawan

2108030043

Dosen pembinmbing:

Dr.Ir.Heru Mirmanto,MT

TUGAS AKHIR

KONVERSI ENERGI

Page 2: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

GAMBAR INSTALASI POMPA

Page 3: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

PT PERTAMINA Production Unit Gresik merupakan perusahaan yang bergerak dibidang produksi pelumas. Kegiatan Pada perusahaan ini ialah memproduksi minyak pelumas untuk kebutuhan industri, marine dan otomotif. Mengingat sangat pentingnya peralatan pompa yang digunakan untuk melayani proses produksi pelumas, maka pada tugas akhir ini kami tertarik untuk mempelajari pompa penyalur base oil, yang merupakan bahan dasar dari produk pelumas.

LATAR BELAKANG

Page 4: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

Dalam tugas akhir ini kami ingin mempelajari perencanaan ulang instalasi pompa base oil di PT PERTAMINA.Hal ini terkait dengan bagaimana Head Efektif Instalasi, Kapasitas serta Pemilihan Pompa yang digunakan.

PERUMUSAN MASALAH

Page 5: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

TUJUAN

1. Menghitung kapasitas tiap-tiap tangki discharge reservoir yaitu tangki ABB (Automatic Batch Blending)

dan tanki Mixer.

2. Menghitung Head efektifInstalasi pompa.

3. Pemilihan pompa beserta dayayang dibutuhkan.

Page 6: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

Permasalahan ini dibatasi pada pemilihan pompa penyalur base oilpada tanki ABB (Automatic Batch Blending) dan tanki mixer di PT PERTAMINA Production Unit Gresik.

Batasan Masalah

Page 7: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

DIAGRAM ALIR

METODE PENELITIAN

START

Study literature dan survey diPT PERTAMINA

Pengambilan data

Perhitungan:-kapasitas-kecepatan aliran-head pompa

-daya pompa

Pemilihan Pompa

Kesimpulan

tidak

Page 8: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

3.1.1. Data PompaJenis pompa :TM GM360-150 –RANGE TOP GEAR JHONSON PUMPKapasitas :130 m3/hrPressure max :16 barPutaran max :600 rpmPompa yang digunakan :1 unitDaya motor :18,5 KW

3.1.2. Data PipaDiameter pipa (NPS) :8inch ; 6inch; 4inchKetebalan ( schedule ) :40Bahan pipa :Carbon SteelAsesoris :Gate valve

Butterfly valveElbow 90o long radius typeSambungan TeeCheck Valve disc typeStainerExit pipe type sharp-edgeEntrance type sharp-edge

3.1.3. Data FluidaFluida kerja : Base Oil / HVI 160SViscositas : 10,80x10-6 m2/sTemperatur kerja : 30o CSG ( Spesific Gravity ) : 0,827Density : 882,7 kg/m3

Data-Data Hasil Survey

Page 9: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

3.1.4. Data Suction Reservoir

Gambar 3.1 Tanki Suction ReservoirKeterangan:Tinggi lubang ukur A: 15015 mmTinggi tanki B: 14600 mmTinggi maksimum volume bersih C: 14400 mmTinggi meja ukur D: 500 mmTinggi dasar tanki E: 0 mmTinggi minimal fluida F: 700 mmTekanan 1 atm

Data-Data Hasil Survey

Page 10: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

DATA PERHITUNGAN INSTALASI

HASIL PERHITUNGAN

Page 11: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

DATA DAYA

HASIL PERHITUNGAN

Page 12: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

Dari data perhitungan untuk kondisi (Q= 0.022425m3/s =355,443 GPM) dan (H= 13.480m = 44,22 ft) didapat pompauntuk instalasi adalah jenis Gear Pump

DIAGRAM PEMILIHAN POMPA

Page 13: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

Berdasarkan hasil perhitungan head dan kapasitas serta mempertimbangkan daya penggerak, daya poros dan putaran pompa maka,dapat dipilih pompa jenis :

Jenis pompa : Pompa Gear

Putaran : 600 rpm

Tipe / Merk : TM GM185-125-RANGE TOP GEAR JHONSON PUMP

Kapasitas : 83 m3/hr

Maximum Pressure : 16 bar

Daya Penggerak : 18.5 KW

PENENTUAN POMPA

Page 14: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

Berdasarkan hasil perhitungan dapat disimpulkan sebagai berikut:• Kapasitas base oil yang dibutuhkan untuk memenuhi

proses produksi sebesar 0.022425= 80.73 m3/jam. maka, kapasitas inilah yang harus dipenuhi oleh pompa yang dipilih.

• Berdasarkan hasil perhitungan Head Efektif pompa (Heff) diperoleh Head sebesar = 13.480 m

• Berdasarkan hasil perhitungan daya penggerak pompa. Didapatkan daya sebesar = 4.620 KW.

• Pompa yang dipilih adalah jenis pompa gear dalam tipe TM GM185-125-RANGE TOP GEAR JHONSON PUMPUntuk memenuhi kebutuhan menyalurkan base oildalam produksi minyak pelumas serta daya penggerak yang dibutuhkan.

KESIMPULAN

Page 15: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

Untuk kondisi operasi yang telah direncanakan(Q=0.022425m3/s dan H=13.480m) maka, disarankanmemilih pompa gear pump tipe TM GM185-125-RANGETOPGEAR JOHNSON PUMP.

Pada survey dilapangan digunakan pompa TM GM360-150-RANGE TOPGEAR JOHNSON PUMP hal ini didasarkanapabila ada pengembangan kapasitas ditahun-tahunberikutnya

SARAN

Page 16: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki

SPESIFIKASI POMPA

SPESIFIKASI POMPA

Page 17: PERENCANAAN ULANG INSTALASI POMPA …digilib.its.ac.id/public/ITS-paper-25098-2108030043-Presentation.pdf · tangki discharge reservoir yaitu ... (Automatic Batch Blending) dan tanki