pengaruh ukuran spesimen terhadap hubungan tegangan … · compressive strength compares to normal...

21
i PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN DAN REGANGAN PADA BETON HIGH VOLUME FLY ASH SELF COMPACTING CONCRETE (HVFA SCC) The Effect of Specimen Size on Stress Strain Behaviour of High Volume Fly Ash Self Compacting Concrete (HVFA SCC) SKRIPSI Disusun Untuk Memenuhi Persyaratan Memperoleh Gelar Sarjana Teknik Pada Program Studi Teknik Sipil Fakultas Teknik Universitas Sebelas Maret Surakarta Disusun oleh: FITRIA RINDANG NUR INSYIROH NIM. I0113047 PROGRAM STUDI TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS SEBELAS MARET SURAKARTA 2017

Upload: lamdung

Post on 13-May-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

i

PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN

DAN REGANGAN PADA BETON HIGH VOLUME FLY ASH – SELF

COMPACTING CONCRETE (HVFA – SCC)

The Effect of Specimen Size on Stress – Strain Behaviour of High Volume Fly Ash –

Self Compacting Concrete (HVFA – SCC)

SKRIPSI

Disusun Untuk Memenuhi Persyaratan Memperoleh Gelar Sarjana Teknik

Pada Program Studi Teknik Sipil Fakultas Teknik

Universitas Sebelas Maret

Surakarta

Disusun oleh:

FITRIA RINDANG NUR INSYIROH

NIM. I0113047

PROGRAM STUDI TEKNIK SIPIL FAKULTAS TEKNIK

UNIVERSITAS SEBELAS MARET

SURAKARTA

2017

Page 2: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

ii

Page 3: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

iii

Page 4: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

iv

MOTTO

Maka sesungguhnya bersama kesulitan ada kemudahan. Sesungguhnya bersama

kesulitan ada kemudahan. Maka apabila engkau telah selesai (dari sesuatu urusan),

tetaplah bekerja keras (untuk urusan yang lain). Dan hanya kepada Tuhanmulah

engkau berharap. – Q.S. Al-Insyirah, 6-8

Barang siapa menginginkan kebahagiaan didunia dan diakhirat maka haruslah

memiliki banyak ilmu. – H.R. Ibnu Asakir

Banyak kegagalan dalam hidup ini dikarenakan orang-orang tidak menyadari betapa

dekatnya mereka dengan keberhasilan saat mereka menyerah. – Thomas Alva

Edison

Be grateful in every condition.

Page 5: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

v

HALAMAN PERSEMBAHAN

Puji syukur atas berkat rahmat Allah SWT atas nikmat iman, nikmat sehat dan nikmat

ilmu sehingga penyusun dapat menyelesaikan pengerjaan laporan skripsi ini.

Penyusun pada kesempatan ini mengucapkan terimakasih yang sebesar besarnya

kepada :

Keluarga yang selalu berada di samping (Bapak, Ibu dan saudara), terimakasih atas

semua doa, kepercayaan, motivasi dan dorongan sehingga skripsi ini dapat

terselesaikan, semoga selalu berada dalam penjagaan Allah SWT baik di dunia

ataupun di akhirat kelak.

Bapak Agus Setiya Budi S.T, M.T. beserta Bapak Dr. Senot Sangadji, S.T., M.T.

yang telah sabar, membimbing dan meluangkan waktunya untuk menyelesaikan

penyusunan skripsi ini.

Teman-teman tim TEGAR, terimakasih atas kerjasama, kekompakan dan semangat

selama ini, semoga kita akan terus mengingat ini sebagai pengalaman yang indah dan

mengingat satu sama lain.

Teman-teman Teknik Sipil UNS angkatan 2013 serta angkatan lainnya, yang banyak

membantu baik dalam bidang akademis kampus ataupun non akademis.

Page 6: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

vi

ABSTRAK

Fitria Rindang Nur Insyiroh, 2017, Pengaruh Ukuran Spesimen terhadap

Hubungan Tegangan dan Regangan pada High Volume Fly Ash Self Compacting

Concrete (HVFA-SCC), Tugas Akhir Program Studi Teknik Sipil Fakultas Teknik

Universitas Sebelas Maret Surakarta.

Fly ash merupakan limbah dari sisa pembakaran batu bara yang berbentuk partikel amorf.

Dalam penggunaannya sebagai bahan tambah, fly ash memiliki ukuran butiran yang lebih

bulat dan halus dibandingkan semen dan bersifat pozzolan yang berarti fly ash dapat bereaksi

dengan kapur pada suhu kamar dengan media air membentuk senyawa yang bersifat

mengikat seperti semen. Penggunaan fly ash dengan kadar minimal 50% dari berat binder

sebagai pengganti semen disebut dengan High Volume Fly Ash Concrete. Sedangkan

teknologi High Volume Fly Ash – Self Compacting Concrete (HVFA – SCC) merupakan

perpaduan antara beton yang menggunakan kadar fly ash tinggi dengan beton memadat

sendiri. Standar pengujian sampel silinder di lapangan berukuran 15 cm x 30 cm. Seiring

perkembangan pengetahuan dan teknologi, diizinkan ukuran sampel silinder yang lebih kecil

dengan ketentuan pemakaian ukuran maksimum nominal agregat tidak lebih dari ⅓ diameter

sampel silinder itu sendiri. Penelitian ini mengkaji tentang pengaruh perbedaan ukuran

spesimenbenda uji silinder terhadap hubungan tegangan dan regangan pada HVFA – SCC.

Hal – hal yang dikaji meliputi kuat desak beton, grafik hubungan tegangan – regangan,

modulus elastisitas beton, nilai indeks toughness, dan daktilitas.

Penelitian ini menggunakan metode eksperimen yang dilakukan di Laboratorium Bahan &

Struktur Program Studi Teknik Sipil UNS serta Laboratorium Material Program Studi Teknik

Mesin UNS. Penelitian ini membandingkan 3 variasi ukuran spesimen dengan rasio

perbandingan diameter dan tinggi yang sama untuk benda uji HVFA – SCC dan beton

normal. Benda uji yang digunakan berbentuk silinder dengan variasi diameter 5 cm, 7,5 cm,

11 cm dengan masing – masing variasi tinggi 10 cm, 15 cm, 22 cm. Rancang campur yang

digunakan pada High Volume Fly Ash Self Compacting Concrete menggunakan teknologi

Self-Compacting Concrete (SCC) berdasar EFNARC Specification and Guidelines for Self-

Compacting Concrete, 2002.

Hasil dari penelitian ini menunjukkan bahwa perbedaan ukuran spesimen benda uji silinder

dengan rasio perbandingan diameter dan tinggi yang tetap akan menghasilkan karakteristik

yang relatif hampir sama pada umur 28 hari. Penggunaan fly ash sebagai pengganti

semen meningkatkan nilai indeks toughness dibandingkan dengan beton normal,

yaitu 0,075953 pada HVFA-SCC dan 0,069491 pada beton normal. Daktilitas beton

HVFA-SCC lebih tinggi sebesar 6,06772 dibandingkan beton normal sebesar

4,26767. Sedangkan kuat tekan rata-rata beton normal lebih tinggi sebesar 33,3957

MPa dibanding HVFA-SCC sebesar 26,5967 MPa.

Kata kunci : size effect, tegangan dan regangan, fly ash, HVFA-SCC, indeks

thoughness, daktilitas

Page 7: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

vii

ABSTRACT

Fitria Rindang Nur Insyiroh, 2017, Effect of Speciment Size on Stress-Strain

Behavior of High Volume Fly ash – Self Compacting Concrete (HVFA-SCC),

Final Project of Civil Engineering Department Faculty of Engineering Sebelas Maret

University Surakarta.

Fly ash is a waste of coal combustion in the form of amorphous particles. Fly ash has

a more rounded and smooth grain size than cement and it has character as a pozzolan

which means, fly ash can react with lime at room temperature with water as a

medium, to make binding compounds such as cement. The use of 50% fly ash a

partial replacement of cement in a mixture is called High Volume Fly Ash Concrete

(HVFAC). High Volume Fly Ash - Self Compacting Concrete (HVFA - SCC)

technology is a combination of concrete that uses high fly ash content with self

compacting concrete. Standard testing of cylindrical samples is 15 cm x 30 cm. As

the development of knowledge and technology, allowed the smaller sample size of

the cylinders with requirentment the maximum size of the aggregate is not more than

⅓ from the diameter of the cylinder sample. This reasearch will examine the effect of

different specimen sizes of cylinder on stress and strain behavior on HVFA - SCC.

Several things are also being examined, which are the compressive strength of

concrete, stress-strain relation graph, the modulus of concrete elasticity, and index

toughness value.

This research uses experimental methods conducted in the Materials & Structures

Laboratory and Material Laboratory of Faculty of Engineering in UNS. This research

compared 3 variations of the specimen size with the same diameter and height ratio

for the HVFA - SCC and normal concrete specimens. The specimens were used

sample with variation of diameter 5 cm, 7.5 cm, 11 cm with each height variation 10

cm, 15 cm, 22 cm. The mixed design used in High Volume Fly Ash Self Compacting

Concrete uses Self-Compacting Concrete (SCC) technology based on EFNARC

Specification and Guidelines for Self-Compacting Concrete, 2002.

According to the research result, it was found that HVFA-SCC at 28 days had lower

compressive strength compares to normal concrete, 33,3957 MPa for normal concrete

and 26,5967 MPa for HFVA-SCC.. In the other hand, the difference in the specimen

size of cylindrical test with fixed ratio of diameter and height will give a result of

relatively similar characteristics at 28 days. The use of fly ash as a substitute for

cement increases the toughness index value compared with the normal concrete, ie

0.075953 for HVFA-SCC and 0.069491 for normal concrete. HVFA-SCC concrete

ductility is higher at 6,06772 than normal concrete 4,26767.

Keywords: size effect, stress and strain, fly ash, HVFA-SCC, index thoughness,

ductility

Page 8: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

viii

PENGANTAR

Puji syukur kehadirat Allah SWT yang telah melimpahkan rahmat serta hidayah-Nya

sehingga penulis dapat menyelesaikan penyusunan skripsi dengan judul Pengaruh

Ukuran Spesimen terhadap Hubungan Tegangan dan Regangan pada High Volume

Fly Ash Self Compacting Concrete.

Penulis menyadari sepenuhnya bahwa tanpa bantuan dari berbagai pihak banyak

kendala yang sulit untuk penyusun hadapi sehingga terselesaikanya penyusunan

skripsi ini. Penulis ingin mengucapkan terimakasih kepada:

1. Keluarga yang telah mendukung baik secara moril dan materiil serta senantiasa

memberi motivasi dalam pengerjaan skripsi.

2. Wibowo, S.T., DEA, selaku Kepala Program Studi Teknik Sipil Fakultas Teknik

Universitas Sebelas Maret Surakarta.

3. Agus Setiya Budi, S.T., M.T., selaku Dosen Pembimbing I skripsi. Terimakasih

atas semua waktu, bimbingan, motivasi, serta bantuanya selama penyusunan

skripsi ini sampai selesai.

4. Dr. Senot Sangadji, S.T., M.T., selaku Dosen Pembimbing II skripsi. Terimakasih

atas semua waktu, bimbingan, motivasi, serta bantuanya selama penyusunan

skripsi ini sampai selesai.

5. Ir. Budi Utomo, M.T., selaku Dosen Pembimbing Akademik. Terimakasih atas

semua waktu, bimbingan, motivasi, serta bantuanya selama penyusunan skripsi ini

sampai selesai.

6. Semua Staf Pengajar Program Studi Teknik Sipil Fakultas Teknik Universitas

Sebelas Maret Surakarta.

7. Staf pengelola / laboran Laboratorium Bahan Bangunan dan Struktur Program

Studi Teknik Sipil Fakultas Teknik Universitas Sebelas Maret Surakarta.

Page 9: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

ix

8. Seluruh anggota skripsi tim TEGAR angkatan 2013, semoga dengan semua yang

telah terlewati ini kita menjadi pribadi yang lebih kuat kedepannya. Semoga kita

semua sukses kedepannya dan selamat berjuang.

9. Teman-teman mahasiswa Reguler Teknik Sipil angkatan 2013. Terimakasih untuk

persahabatan, perjuangan, kebersamaan, dan semangatnya selama ini.

10.Semua orang yang telah terlibat baik langsung atau secara tidak langsung dalam

penyusunan skripsi ini yang tidak bisa Penulis sebutkan satu per satu.

Penulis menyadari bahwa skripsi ini masih jauh dari sempurna. Saran dan kritik yang

membangun sangat penulis harapkan, semoga skripsi ini dapat berguna bagi pihak-

pihak yang membutuhkan, khususnya bagi penulis sendiri.

Surakarta, Agustus 2017

Penyusun

Page 10: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

x

DAFTAR ISI

HALAMAN JUDUL ..................................................................................................... i

HALAMAN PERSETUJUAN .................................... Error! Bookmark not defined.

PENGESAHAN SKRIPSI .......................................... Error! Bookmark not defined.

MOTTO ....................................................................................................................... iii

HALAMAN PERSEMBAHAN ................................................................................... v

ABSTRAK ................................................................................................................... vi

ABSTRACT ................................................................................................................ vii

PENGANTAR ........................................................................................................... viii

DAFTAR ISI ................................................................................................................. x

DAFTAR TABEL ...................................................................................................... xiv

DAFTAR GAMBAR ................................................................................................. xvi

DAFTAR LAMPIRAN ............................................................................................ xviii

DAFTAR NOTASI DAN SIMBOL .......................................................................... xix

BAB 1 PENDAHULUAN .......................................... Error! Bookmark not defined.

1.1 Latar Belakang ............................................. Error! Bookmark not defined.

1.2 Rumusan Masalah ........................................ Error! Bookmark not defined.

1.3 Batasan Masalah........................................... Error! Bookmark not defined.

1.4 Tujuan Penelitian ......................................... Error! Bookmark not defined.

1.5 Manfaat Penelitian ....................................... Error! Bookmark not defined.

BAB 2 TINJAUAN PUSTAKA DAN LANDASAN TEORIError! Bookmark not

defined.

2.1 Tinjauan Pustaka .......................................... Error! Bookmark not defined.

2.2 Landasan Teori ............................................. Error! Bookmark not defined.

2.2.1 Beton Self Compacting Concrete (SCC) ...... Error! Bookmark not defined.

Page 11: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xi

2.2.1.1 Pengertian Self Compacting Concrete (SCC)Error! Bookmark not

defined.

2.2.1.2 Sifat dan Metode Uji Self Compacting Concrete (SCC)Error! Bookmark

not defined.

2.2.1.3 Kelebihan dan Kekurangan Self Compacing Concrete (SCC) .............. Error!

Bookmark not defined.

2.2.2 Reaksi Pozolanic .......................................... Error! Bookmark not defined.

2.2.3 High Volume Fly Ash – Self Compacting Concrete (HVFA – SCC) .. Error!

Bookmark not defined.

2.2.3.1 Pengertian High Volume Fly Ash – Self Compacting Concrete (HVFA-

SCC) ............................................................. Error! Bookmark not defined.

2.2.2.2 Material Penyusun High Volume Fly Ash – Self Compacting Concrete

(HVFA – SCC) ............................................. Error! Bookmark not defined.

2.2.4 Mix Design ................................................... Error! Bookmark not defined.

2.2.4.1 Mix Design Beton Normal ........................... Error! Bookmark not defined.

2.2.4.2 Mix Design High Volume Fly Ash – Self Compacting Concrete (HVFA –

SCC) ............................................................. Error! Bookmark not defined.

2.2.5 Kuat Desak Beton ........................................ Error! Bookmark not defined.

2.2.6 Perngertian Tegangan dan Regangan Beton Error! Bookmark not defined.

2.2.7 Modulus Elastisitas ...................................... Error! Bookmark not defined.

2.2.8 Size Effect .................................................... Error! Bookmark not defined.

2.2.9 Load Rate Pengujian Beton Silinder ............ Error! Bookmark not defined.

2.2.10 Kurva Tegangan – Regangan Beton ............ Error! Bookmark not defined.

2.2.11 Daktilitas ...................................................... Error! Bookmark not defined.

BAB 3 METODE PENELITIAN................................ Error! Bookmark not defined.

3.1 Tinjauan Umum ........................................... Error! Bookmark not defined.

3.2 Bahan............................................................ Error! Bookmark not defined.

Page 12: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xii

3.2.1 Agregat Kasar............................................... Error! Bookmark not defined.

3.2.2 Agregat Halus............................................... Error! Bookmark not defined.

3.2.3 Semen ........................................................... Error! Bookmark not defined.

3.2.4 Fly Ash ......................................................... Error! Bookmark not defined.

3.2.5 Air ................................................................ Error! Bookmark not defined.

3.2.6 Superplasticizer ............................................ Error! Bookmark not defined.

3.3 Benda Uji Penelitian .................................... Error! Bookmark not defined.

3.4 Peralatan Penelitian ...................................... Error! Bookmark not defined.

3.5 Diagram Alir ................................................ Error! Bookmark not defined.

3.6 Tahap Penelitian ........................................... Error! Bookmark not defined.

3.6.1 Studi Literatur dan Persiapan Bahan ............ Error! Bookmark not defined.

3.6.2 Pengujian Bahan........................................... Error! Bookmark not defined.

3.6.3 Perencanaan Rancang Campur High Volume Fly Ash – Self Compacting

Concrete (HVFA – SCC) ............................. Error! Bookmark not defined.

3.6.4 Mencetak Benda Uji High Volume Fly Ash – Self Compacting Concrete

(HVFA – SCC) ............................................. Error! Bookmark not defined.

3.6.5 Perawatan High Volume Fly Ash – Self Compacting Concrete (HVFA –

SCC) ............................................................. Error! Bookmark not defined.

3.6.6 Pengujian Benda Uji .................................... Error! Bookmark not defined.

3.6.7 Analisis Data ................................................ Error! Bookmark not defined.

3.6.8 Kesimpulan dan Saran.................................. Error! Bookmark not defined.

BAB 4 HASIL PENELITIAN & PEMBAHASAN .... Error! Bookmark not defined.

4.1 Hasil Analisis Pengujian Bahan ................... Error! Bookmark not defined.

4.1.1 Hasil Pengujian Agregat Halus .................... Error! Bookmark not defined.

4.1.2 Hasil Pengujian Agregat Kasar .................... Error! Bookmark not defined.

4.1.3 Hasil Pengujian Fly Ash .............................. Error! Bookmark not defined.

4.2 Rancang Campuran Adukan Beton .............. Error! Bookmark not defined.

Page 13: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xiii

4.3 Hasil Pengujian Sampel Silinder .................. Error! Bookmark not defined.

4.3.1 Hasil Pengujian Berat Volume ..................... Error! Bookmark not defined.

4.3.2 Hasil Pengujian Kuat Desak Beton .............. Error! Bookmark not defined.

4.3.3 Hasil Pengujian Grafik Hubungan Tegangan-ReganganError! Bookmark

not defined.

BAB 5 KESIMPULAN DAN SARAN ..................... Error! Bookmark not defined.

5.1 Kesimpulan .................................................. Error! Bookmark not defined.

5.2 Saran ............................................................. Error! Bookmark not defined.

DAFTAR PUSTAKA ................................................. Error! Bookmark not defined.

Page 14: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xiv

DAFTAR TABEL

Tabel 2.1 Identifikasi Pasing Ability Menggunakan Metode J - Ring Test .... Error!

Bookmark not defined.

Tabel 2.2 Jenis dan Penggunaan Semen Portland . Error! Bookmark not defined.

Tabel 2.3 Komposisi Material Kimia Semen (% dalam berat)Error! Bookmark

not defined.

Tabel 2.4 Senyawa Kimia Fly Ash ......................... Error! Bookmark not defined.

Tabel 2.5 Kandungan Kimia Fly Ash PLTU JeparaError! Bookmark not defined.

Tabel 2.6 Data Teknis Sika Viscocrete 10 ............. Error! Bookmark not defined.

Tabel 2.7 Syarat Prosentase Berat Lolos Saringan berdasarkan ASTMC C 33

................................................................ Error! Bookmark not defined.

Tabel 2.8 Tabel Perubahan Warna ......................... Error! Bookmark not defined.

Tabel 2.9 Pengaruh Zat Organik Terhadap Presentase Penurunan Kekuatan

Beton ...................................................... Error! Bookmark not defined.

Tabel 2. 10 Perkiraan Kekuatan Tekan (MPa) Beton dengan Faktor Air-Semen, dan

Agregat Kasar Yang Biasa Dipakai di IndonesiaError! Bookmark not

defined.

Tabel 2.11 Persyaratan Jumlah Semen Minimum dan Faktor Air Semen Maksimum

Untuk Berbagai Macam Pembetonan Dalam Lingkungan Khusus. Error!

Bookmark not defined.

Tabel 2.12 Perkiraan Kadar Air Bebas (kg/m3) Yang Dibutuhkan Untuk Beberapa

Tingkat Kemudahan Pekerjaan Adukan BetonError! Bookmark not

defined.

Tabel 2. 13 Daerah Gradasi Agregat Halus............... Error! Bookmark not defined.

Tabel 2.14 Mix Design range yang disarankan oleh The European Guidelines for

Self-Compacting Concrete (2005) ......... Error! Bookmark not defined.

Tabel 2.15 Kecepatan pembebanan benda uji silinder berdasarkan ukuran

diameter .................................................. Error! Bookmark not defined.

Page 15: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xv

Tabel 3.1 Rincian Sampel Benda Uji ..................... Error! Bookmark not defined.

Tabel 3.2 Parameter Pengujian Fly Ash ................. Error! Bookmark not defined.

Tabel 4.1 Hasil Pengujian Agregat Halus .............. Error! Bookmark not defined.

Tabel 4.2 Hasil Pengujian Agregat Kasar .............. Error! Bookmark not defined.

Tabel 4.3 Hasil Pengujian Fly Ash dari PLTU JeparaError! Bookmark not

defined.

Tabel 4.4 Hasil Pengujian Berat Volume Beton NormalError! Bookmark not

defined.

Tabel 4.5 Hasil Pengujian Berat Volume Beton Jenis HVFA-SCC ............... Error!

Bookmark not defined.

Tabel 4.6 Hasil Pengujian Kuat Desak Beton NormalError! Bookmark not

defined.

Tabel 4.7 Hasil Pengujian Kuat Desak Beton Jenis HVFA-SCCError! Bookmark

not defined.

Tabel 4.8 Hasil data dari hubungan tegangan-regangan HVFA-SCC ............ Error!

Bookmark not defined.

Tabel 4.9 Hasil data dari hubungan tegangan-regangan Beton Normal ......... Error!

Bookmark not defined.

Tabel 4. 10 Nilai Toughness HVFA-SCC dan Beton NormalError! Bookmark not

defined.

Tabel 4.11 Nilai Daktilitas berdasar Luasan di Bawah GrafikError! Bookmark not

defined.

Tabel 4.12 Nilai Daktilitas berdasar Regangan ........ Error! Bookmark not defined.

Tabel 4.13 Perbandingan Besar Regangan Lateral pada Tegangan yang SamaError!

Bookmark not defined.

Page 16: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xvi

DAFTAR GAMBAR

Gambar 2.1 Prinsip Dasar Preses Produksi Self Compacting Concrete .......... Error!

Bookmark not defined.

Gambar 2.2 Perbandingan Proporsi Campuran Self Compacting Concrete .... Error!

Bookmark not defined.

Gambar 2.3 Pengujian Slump Flow Beton SCC (ASTM C 1611)Error! Bookmark

not defined.

Gambar 2.4 L – Shape Box Test (EDNARC, 2005) Error! Bookmark not defined.

Gambar 2.5 V - Funnel Test .................................... Error! Bookmark not defined.

Gambar 2.6 Metode U - Box Test pada Beton SCC Error! Bookmark not defined.

Gambar 2.7 Perbedaan Reaksi Hidrasi dan Reaksi PozzolanicError! Bookmark

not defined.

Gambar 2. 8 Reaksi Kimia Senyawa Semen dengan Air dan Hasil Rekasi

Hidrasi ................................................. Error! Bookmark not defined.

Gambar 2.9 Reaksi Pozzolanic Fly Ash .................. Error! Bookmark not defined.

Gambar 2.10 Sketsa Reaksi Hidrasi Semen Konvensional dan beton SCC ...... Error!

Bookmark not defined.

Gambar 2.11 Bentuk Butiran Bulat Fly Ash ............. Error! Bookmark not defined.

Gambar 2.12 Tegangan normal (normal stress) ........ Error! Bookmark not defined.

Gambar 2.13 Regangan (strain) ................................ Error! Bookmark not defined.

Gambar 2.14 Grafik Rasio (l/d) terhadap Kuat Tekan Beton (Mindess, 2003) . Error!

Bookmark not defined.

Gambar 2.15 Zona Batas dikarenakan Pengekangan Gesek untuk Spesimen dengan

kelangsingan berbeda (Van Vliet and Van Mier, 1996) .............. Error!

Bookmark not defined.

Gambar 2.16 Kurva relasi tegangan-regangan untuk beberapa jenis beton ....... Error!

Bookmark not defined.

Gambar 3.1 Kerikil Kulonprogo ............................. Error! Bookmark not defined.

Gambar 3.2 Pasir ..................................................... Error! Bookmark not defined.

Page 17: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xvii

Gambar 3.3 Semen OPC Jayamix ........................... Error! Bookmark not defined.

Gambar 3.4 Fly Ash ................................................ Error! Bookmark not defined.

Gambar 3.5 Sika Viscocrete .................................... Error! Bookmark not defined.

Gambar 3.6 Timbangan........................................... Error! Bookmark not defined.

Gambar 3.7 Ayakan ................................................ Error! Bookmark not defined.

Gambar 3.8 Mesin Penggetar Ayakan .................... Error! Bookmark not defined.

Gambar 3.9 Oven .................................................... Error! Bookmark not defined.

Gambar 3.10 Corong Kronik .................................... Error! Bookmark not defined.

Gambar 3.11 Mesin Los Angeles .............................. Error! Bookmark not defined.

Gambar 3.12 Kerucut Abrams .................................. Error! Bookmark not defined.

Gambar 3.13 Mesin Uji Kuat Desak ......................... Error! Bookmark not defined.

Gambar 3.14 Alat Bantu ........................................... Error! Bookmark not defined.

Gambar 3.15 Diagram Alir ....................................... Error! Bookmark not defined.

Gambar 3.16 Pengujian Kadar Lumpur Agregat HalusError! Bookmark not

defined.

Gambar 3.17 Pengujian Kadar Zat Organik Agregat HalusError! Bookmark not

defined.

Gambar 3.18 Pengujian Slump Flow ........................ Error! Bookmark not defined.

Gambar 3.19 Diagram Alir Rancang Campur Beton Error! Bookmark not defined.

Gambar 3.20 Sketsa Benda Uji Peenelitian .............. Error! Bookmark not defined.

Gambar 4.1 Grafik Kurva Tegangan-Regangan HVFA-SCC dan Beton Normal

............................................................. Error! Bookmark not defined.

Gambar 4.2 Grafik Perbandingan Kurva Tegangan-Regangan HVFA-SCC .. Error!

Bookmark not defined.

Gambar 4.3 Grafik Perbandingan Kurva Tegangan-Regangan Beton Normal Error!

Bookmark not defined.

Gambar 4.4 Perbandingan Kuat Tekan HVFA-SCC dengan Beton Normal ... Error!

Bookmark not defined.

Gambar 4.5 Perbandingan Regangan Maksimal Sampel HVFA-SCC denga nBeton

Normal................................................. Error! Bookmark not defined.

Page 18: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xviii

Gambar 4.6 Perbandingan Modulus Elastisitas Sampel HVFA-SCC dengan Beton

Normal................................................. Error! Bookmark not defined.

Gambar 4.7 Grafik Hubungan Tegangan dan Regangan Lateral pada Sampel

HVFA-SCC 5 cm ................................ Error! Bookmark not defined.

Gambar 4.8 Grafik Hubungan Tegangan dan Regangan Lateral pada Sampel

HVFA-SCC 7,5 cm ............................. Error! Bookmark not defined.

Gambar 4.9 Grafik Hubungan Tegangan dan Regangan Lateral pada Sampel

HVFA-SCC 11 cm .............................. Error! Bookmark not defined.

Page 19: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xix

DAFTAR LAMPIRAN

Lampiran A : Hasil Pengujian Agregat Halus

Lampiran B : Hasil Pengujian Agregat Kasar

Lampiran C : Hasil Pengujian Fly Ash

Lampiran D : Mix Design Rencana

Lampiran E : Grafik Hasil Pengujian UTM

Lampiran F : Dokumentasi Penelitian

Page 20: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xx

DAFTAR NOTASI DAN SIMBOL

% = presentase

cm = centimeter

mm = millimeter

Ca(OH)2 = Kalsium Hidroksida

SiO2 = Silica

C3S = Trikalsium Silikat

C2S = Dikalsium Silikat

H2O = air

C-S-H = gel tobermorite

OPC = Ordinary Portland Cement

M = nilai tambah

MPa = Mega Pascal

Sr = deviasi standar rencana

f’cr = kuat tekan rata-rata

f’c = kuat tekan yang disyaratkan

f’c = kuat tekan beton benda uji silinder

P = beban desak maksimum

A = luas permukaan benda uji silinder

σ = tegangan

F = Gaya

ε = Regangan

∆l = Selisih panjang awal dan panjang akhir

l0 = Panjang awal

E = Modulus elastisitas beton

K1 = Keliling Awal (sebelum pembebanan)

K1 = Keliling Akhir (setelah pembebanan)

D1 = Diameter Awal (sebelum pembebanan)

Page 21: PENGARUH UKURAN SPESIMEN TERHADAP HUBUNGAN TEGANGAN … · compressive strength compares to normal concrete, 33,3957 MPa for normal concrete and 26,5967 MPa for HFVA-SCC.. In the

xxi

D2 = Diameter Akhir (setelah pembebanan) xx

𝜀circumferential = Regangan melingkar

𝜀lateral = Regangan lateral

= phi

∆K = selisih keliling

∆D = selisih diameter

Psi = satuan tegangan

S = detik

Lb = pounds

Kg = kilogram

𝜀 = Regangan

f’c = Tegangan puncak

Ec = Modulus Elastisitas beton