BAHAYA LISTRIK BAGI MANUSIA
BAHAYA LISTRIK BAGI MANUSIA
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-1
SHOCK (TERKEJUT)
SHOCK (TERKEJUT)
PINGSANPINGSAN TERBAKARTERBAKAR
KEMATIANKEMATIAN
BAHAYA YANG DITIMBULKAN OLEH ARUS / TEGANGAN LISTRIK
TERHADAP MANUSIA ADALAH :
BAHAYA YANG DITIMBULKAN OLEH ARUS / TEGANGAN LISTRIK
TERHADAP MANUSIA ADALAH :

DENYUT JANTUNG YANG TERSENGAT LISTRIKDENYUT JANTUNG YANG TERSENGAT LISTRIK
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-2
KEADAAN NORMAL TERKENA SENGATAN LISTRIK
DENYUT NORMAL :
80 KALI PER MENIT ---> DIPERINTAHKAN 100 KALI PER DETIK

PENGARUH MEDAN LISTRIKDAN MEDAN MAGNET TERHADAP MANUSIA :
MEDAN LISTRIK [KV / M] MEDAN MAGNET [mT]
MEDAN LISTRIK DAN MEDAN MAGNET DI TEMPAT KERJA :
SUTR, SUTM, SUTT, SUTET MESIN PENDINGIN, MESIN KETIK ELEKTRONIK, MESIN PENDINGI, MESIN PHOTO COPY MESIN LAS ALAT KERJA KOMPUTER DAN PRINTER MESIN KOMPRESOR, DAN LAIN-LAIN
PENGARUH MEDAN LISTRIKDAN MEDAN MAGNET TERHADAP MANUSIA :
MEDAN LISTRIK [KV / M] MEDAN MAGNET [mT]
MEDAN LISTRIK DAN MEDAN MAGNET DI TEMPAT KERJA :
SUTR, SUTM, SUTT, SUTET MESIN PENDINGIN, MESIN KETIK ELEKTRONIK, MESIN PENDINGI, MESIN PHOTO COPY MESIN LAS ALAT KERJA KOMPUTER DAN PRINTER MESIN KOMPRESOR, DAN LAIN-LAIN
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-3

• MEDAN LISTRIK ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA PERTIKEL BERMUATAN LISTRIK YANG TERLETAK DALAM MEDAN TERSEBUT.
• MEDAN LISTRIK ITU SENDIRI TIMBUL OLEH ADANYA PARTIKEL BERMUATAN LISTRIK ATAU DENGAN KATALAIN OLEH ADANYA TEGANGAN LISTRIK
• MEDAN LISTRIK BERKURANG KEKUATANNYA SELARAS DENGAN BERTAMBAHNYA JARAK DARI SUMBER SATUAN DARI MEDAN LISTRIK ADALAH [Kv/M].
• MEDAN LISTRIK ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA PERTIKEL BERMUATAN LISTRIK YANG TERLETAK DALAM MEDAN TERSEBUT.
• MEDAN LISTRIK ITU SENDIRI TIMBUL OLEH ADANYA PARTIKEL BERMUATAN LISTRIK ATAU DENGAN KATALAIN OLEH ADANYA TEGANGAN LISTRIK
• MEDAN LISTRIK BERKURANG KEKUATANNYA SELARAS DENGAN BERTAMBAHNYA JARAK DARI SUMBER SATUAN DARI MEDAN LISTRIK ADALAH [Kv/M].
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-4
MEDAN LISTRIKMEDAN LISTRIK

• MEDAN MAGNET ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA BENDA-BENDA MAGNET ATAU PARTIKEL BERMUATAN LISTRIK.
• MEDAN MAGNET DITIMBULKAN OLEH BENDA-BENDA MAGNET ATAU KONDUKTOR YANG DIALIRI ARUS LISTRIK
• ADA BEBERAPA BESARAN DARI MEDAN MAGNET, SALAH SATUNYA ADALAH INDUKSI MEDAN MAGNET ATAU RAPAT FLUKS MAGNET.
• SATUANNYA T (TESLA) ATAU G (GAUSS) ATAU Wb/m2 (WEBER/METER PERSEGI)
• MEDAN MAGNET ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA BENDA-BENDA MAGNET ATAU PARTIKEL BERMUATAN LISTRIK.
• MEDAN MAGNET DITIMBULKAN OLEH BENDA-BENDA MAGNET ATAU KONDUKTOR YANG DIALIRI ARUS LISTRIK
• ADA BEBERAPA BESARAN DARI MEDAN MAGNET, SALAH SATUNYA ADALAH INDUKSI MEDAN MAGNET ATAU RAPAT FLUKS MAGNET.
• SATUANNYA T (TESLA) ATAU G (GAUSS) ATAU Wb/m2 (WEBER/METER PERSEGI)
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-5
MEDAN MAGNETMEDAN MAGNET

POLA MEDAN LISTRIK DAN MEGNETDARI SUATU KONDUKTOR YANG MENGALIRKAN ARUS LISTRIK
POLA MEDAN LISTRIK DAN MEGNETDARI SUATU KONDUKTOR YANG MENGALIRKAN ARUS LISTRIK
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-6
+ +
KONDUKTOR BERTEGANGAN
MEDAN LISTRIK
MEDAN MAGNET
TANAH/BUMI TANAH/BUMI

MEDAN LISTRIK PADA PERALATAN LISTRIK
MEDAN LISTRIK PADA PERALATAN LISTRIK
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-7
PERALATAN MEDAN LISTRIK
(VOLT / METER)
SELIMUT LISTRIK 250
STEREO SET 90
LEMARI PENDINGIN 60
SETRIKA LISTRIK 60
PENGERING RAMBUT 40
TV BERWARNA 30
16
LAMPU PIJAR 2
PENYEDOT DEBU

MEDAN MAGNETPADA PERALATAN LISTRIK
MEDAN MAGNETPADA PERALATAN LISTRIK
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-8
MEDAN MAGNET ( T) PERALATAN
3 CMPERALATAN 30 CM 100 CM
6 - 2000PENGERING RAMBUT 0,01 - 7 0,01 - 0,3
15 - 1500ALAT CUKUR 0,08 - 5 0,01 - 0,3
4000 - 800BOR LISTRIK 2 - 3,5 0,08 - 0,2
60 - 700MIXER 0,6 - 10 0,02 - 0,025
2,5 - 50TELEVISI 0,04 - 2 0,01 - 0,15
8 - 30SETRIKA LISTRIK 0,12 - 0,3 0,01 - 0,025
0,5 - 1,7LEMARI PENDINGIN 0,01 - 0,25 < 0,01

HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH ITS
HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH ITS
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-9
10
9
8
7
6
5
4
3
2
1
0-25 -15 -12 -9 -7,5 -6 -3 0 3 6 7,5 9 12 15 25
AS TENGAH TOWER
Ambang batas WHO = 1000 mG
MEDAN MAGNET
Jarak Mendatar (m) Obyek Pengukuran : SUTT 500 kVlokasi Ds. Senambung KrianTgl. 13 Juli 1997waktu : Pkl. 15.30-16.30

HASIL PENGUKURAN KUAT MEDAN MAGNET LISTRIK DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH ITS
HASIL PENGUKURAN KUAT MEDAN MAGNET LISTRIK DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH ITS
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-10
5
4
3
2
1
0 -25 -15 -12 -9 -7,5 -6 -3 0 3 6 7,5 9 12 15 25
AS TENGAH TOWER
Ambang batas WHO = 5 kV/m
MEDAN MAGNET
Jarak Mendatar (m) Obyek Pengukuran : SUTT 500 kVlokasi Ds. Senambung KrianTgl. 13 Juli 1997waktu : Pkl. 15.30-16.30

HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 150 KV SAWAHAN BARAT OLEH ITS
HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 150 KV SAWAHAN BARAT OLEH ITS
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-11
10
9
8
7
6
5
4
3
2
1
0-25 -15 -12 -9 -7,5 -6 -3 0 3 6 7,5 9 12 15 25
AS TENGAH TOWER
Ambang batas WHO = 1000 mG
MEDAN MAGNET
Jarak Mendatar (m) Obyek Pengukuran : SUTT 150 kVlokasi Jl. Raya Darmo II SurabayaTgl. 13 Juli 1997waktu : Pkl. 17.00 - 17.30
Ku
at
Me
da
n M
ag
ne
t (m
G)

PEDOMAN NILAI AMBANG BATAS KUAT MEDAN LISTRIK DAN KUAT MEDAN MAGNET YANG
DIPAKAI PLN
PEDOMAN NILAI AMBANG BATAS KUAT MEDAN LISTRIK DAN KUAT MEDAN MAGNET YANG
DIPAKAI PLN
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-12
PERATURAN MEDAN LISTRIK MEDAN MAGNET
STANDAR PLN (SPLN NO. 112/1994)
INIRC MENGENAI PETUNJUK BATAS-BATAS PEMAPARAN TERHADAP MEDAN LISTRIK DAN MEDAN MAGNET (EMF) 50/60 HZ/REKOMENDASI WHO IRPS 1990
WORKING HOUR E (MAX) : 10 kV/m
CONTINOUSLY E (MAX) : 5 Kv/M
WORKING HOUR B (MAX) : 0,5 Mt
CONTINOUSLY B (MAX) : 0,1 Mt
REFERENSI : KEPUTUSAN DIREKSI PT PLN (Persero) NO. 031.K/008/DIR/1997 TANGGAL 14 APRRIL 1997

TEGANGAN YANG TIMBUL AKIBAT ARUS BOCOR / KESALAHAN KE TANAH TERHADAP ORANG YANG BERADA DI SEKITAR INSTALASI TENAGA LISTRIK :
• TEGANGAN SENTUH
• TEGANGAN LANGKAH
• TEGANGAN PINDAH
TEGANGAN YANG TIMBUL AKIBAT ARUS BOCOR / KESALAHAN KE TANAH TERHADAP ORANG YANG BERADA DI SEKITAR INSTALASI TENAGA LISTRIK :
• TEGANGAN SENTUH
• TEGANGAN LANGKAH
• TEGANGAN PINDAH
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-13

TABEL : BESAR DAN LAMA TEGANGAN SENTUH MAKSIMUM
BESAR TEGANGAN SENTUH (V)
AC (RMS) DC
< 50 < 120
50 120
75 140
90 160
110 175
150 200
220 250
280 310
LAMA SENTUHAN
MAKSIMUM (DETIK)
-
5,0
1,0
0,5
0,2
0,1
0,05
0,03
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-14

SEORANG TIDAK BOLEH MENYENTUH WALAU SEKEJAPPUN
PERALATAN DENGAN TEGANGAN DI ATAS 100 VOLT
SEORANG TIDAK BOLEH MENYENTUH WALAU SEKEJAPPUN
PERALATAN DENGAN TEGANGAN DI ATAS 100 VOLT
ATURAN UMUM : ATURAN UMUM :
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-15

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-16
BATASAN BESARNYA ARUS LISTRIK YANG MENGALIR
MELALUI TUBUH MANUSIA SERTA PENGARUH LANGSUNG
YANG DIRASAKAN :
• ARUS PERSEPSI (PERCEPTION CURRENT)
• ARUS MEMPENGARUHI OTOT (LETGO CURRENT)
• ARUS FIBRILASI (FIBRILLATING CURRENT)
• ARUS REAKSI (REACTION CURRENT)
BATASAN BESARNYA ARUS LISTRIK YANG MENGALIR
MELALUI TUBUH MANUSIA SERTA PENGARUH LANGSUNG
YANG DIRASAKAN :
• ARUS PERSEPSI (PERCEPTION CURRENT)
• ARUS MEMPENGARUHI OTOT (LETGO CURRENT)
• ARUS FIBRILASI (FIBRILLATING CURRENT)
• ARUS REAKSI (REACTION CURRENT)
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-17
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
PENGARUH ARUS LISTRIK PADA TUBUH MANUSIA
BESARNYA ARUS PENGARUH PADA TUBUH MANUSIA
BELUM DIRASAKAN PENGARUHNYA0 ……… 0,9 mA
BARUS TERASA ADANYA ARUS LISTRIK0,9 ……… 1,2 mAMULAI TERASA SEAKAN-AKAN ADA YANG MERAYAP DIDALAM TANGAN1,2 ……… 1,6 mA
TANGAN SAMPAI KESIKU MERASA KESEMUTAN 1,6 ……… 6,0 mA
TANGAN MULAI KAKU, RASA KESEMUTAN MAKIN BERTAMBAH6,0 ……… 8,0 mA
RASA SAKIT TIDAKTERTAHANKAN PENGHANTAR MASIH DAPAT
DILEPASKAN DENGAN GAYA YANG BESAR SEKALI
13 ……… 15,0 mA
OTOT TIDAK SANGGUP LAGI MELEPASKAN PENGHANTAR15 ……… 20,0 mA
DAPAT MENGAKIBATKAN KERUSAKAN PADA TUBUH MANUSIA20 ……… 50,0 mA
BATAS ARUS YANG DAPAT MENYEBABKAN KEMATIAN50 ……… 100,0 mA

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-18
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
TAHANAN TUBUH MANUSIA

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-19
JARAK BEBAS MINIMUM ANTARA PENGHANTAR SUTT DAN SUTET
DENGAN TANAH DAN BENDA LAINJARAK BEBAS MINIMUM ANTARA PENGHANTAR SUTT DAN SUTET
DENGAN TANAH DAN BENDA LAIN
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan :
NOLOKASI SUTT
66 KV (M)
SUTT 150 KV
(M)
SIRKIT GANDA
(M)
SIRKIT TUNGGAL
(M)
SUTET 500 KV
LAPANGAN TERBUKA ATAU DAERAH TERBUKA
DAERAH DENGAN KEADAAN TERTENTU :
2.1. BANGUNAN TIDAK TAHAN API
2.2. BANGUNAN TAHAN API
2.3. LALU LINTAS JALAN / JALAN RAYA
2.4. POHON - POHON PADA UMUMNYA, HUTAN, PERKEBUNAN
2.5. LAPANGAN OLAH RAGA
2.6. SUTT LAINNYA, PENGHANTAR UDARA TM, JARINGAN TELEKOMUNIKASI, ANTENA RADIO, ANTENA TELEVISI DAN KERETA GANTUNG
2.7. REL KERETA BIASA
2.8. JEMBATAN BESI, RANGKA BESIPENAHAN PENGHANTAR, KERETA LISTRIK TERDEKAT DSB.
2.9.TITIK TERTINGGI TIANG KAPAL PADA KEDUDUKAN AIR PASANG / TERTINGGI PADA LALU LINTAS AIR
1
2
6,5
12,5
3,5
8
3,5
12,5
3
8
3
3
7,5
13,5
4,5
9
4,5
13,5
4
9
4
4
10
14
8,5
15
8,5
14
8,5
15
8,5
8,5
11
15
8,5
15
8,5
15
8,5
15
8,5
8,5
Catatan:

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-20
PENELITIAN Dr. ANIES - UNIVERSITAS DIPENOGORO (1993)PENELITIAN Dr. ANIES - UNIVERSITAS DIPENOGORO (1993)
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan:
DARI HASIL PENGUKURAN TERNYATA KUAT MEDAN LISTRIK DAN
KUAT MEDAN MAGNET DARI SUTT/SUTET MASIH JAUH DIBAWAH
AMBANG BATAS YANG DIREKOMENDASIKAN WHO/IRPA
SEHINGGA DALAM BATAS TERTENTU (DIATAS) SUTT/SUTET TIDAK
AKAN MENIMBULKAN MASALAH KESEHATAN, NAMUN KETAKUTAN
SERTA KEKHAHAWATIRAN MASYARAKAT ADALAH WAJAR DAN
SEBAGAI UPAYA UNTUK MEPERKECIL DAMPAK NEGATIF SUTT /
SUTET TERHADAP KESEHATAN MASYARAKAT, PERLU DILAKUKAN
PENYULUHAN YANG EFEKTIF KEPADA MASYARAKAT UMUM.
DARI HASIL PENGUKURAN TERNYATA KUAT MEDAN LISTRIK DAN
KUAT MEDAN MAGNET DARI SUTT/SUTET MASIH JAUH DIBAWAH
AMBANG BATAS YANG DIREKOMENDASIKAN WHO/IRPA
SEHINGGA DALAM BATAS TERTENTU (DIATAS) SUTT/SUTET TIDAK
AKAN MENIMBULKAN MASALAH KESEHATAN, NAMUN KETAKUTAN
SERTA KEKHAHAWATIRAN MASYARAKAT ADALAH WAJAR DAN
SEBAGAI UPAYA UNTUK MEPERKECIL DAMPAK NEGATIF SUTT /
SUTET TERHADAP KESEHATAN MASYARAKAT, PERLU DILAKUKAN
PENYULUHAN YANG EFEKTIF KEPADA MASYARAKAT UMUM.

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-21
PENELITIAN SOSIOLOGI KASNODIHARDJO DAN SOESANTO (1995)PENELITIAN SOSIOLOGI KASNODIHARDJO DAN SOESANTO (1995)
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan:
PENELITIAN-PENELITIAN SOSIOLOGI KASNODIHARDJO DAN
SOESANTO (1995) DAN GANIHARTONO (1995), YANG BERUSAHA
MENILIK KEADAAN DAN HUBUNGAN SOSIAL EKONOMI DAN
GANGGUAN SUTET 500 KV YANG DIKELUHKAN PENDUDUK
DIDAERAH CIBINONG DAN BEKASI JAWA BARAT, TELAH
MENUNJUKAN BAHWA TIDAK ADA HUBUNGAN LANGSUNG
ANTARA KETERPAPARAN PENDUDUK YANG BERADA DIBAWAH
JARINGAN SUTET DENGAN PENYAKIT YANG DILAPORKAN
ATAUPUN TINGKAT KESEHATAN MASYARAKAT
PENELITIAN-PENELITIAN SOSIOLOGI KASNODIHARDJO DAN
SOESANTO (1995) DAN GANIHARTONO (1995), YANG BERUSAHA
MENILIK KEADAAN DAN HUBUNGAN SOSIAL EKONOMI DAN
GANGGUAN SUTET 500 KV YANG DIKELUHKAN PENDUDUK
DIDAERAH CIBINONG DAN BEKASI JAWA BARAT, TELAH
MENUNJUKAN BAHWA TIDAK ADA HUBUNGAN LANGSUNG
ANTARA KETERPAPARAN PENDUDUK YANG BERADA DIBAWAH
JARINGAN SUTET DENGAN PENYAKIT YANG DILAPORKAN
ATAUPUN TINGKAT KESEHATAN MASYARAKAT

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-22
PENELITIAN BUDI HARYANTO SKM, MSc BALITBANG DEPKES RI
(1995/ 1996)
PENELITIAN BUDI HARYANTO SKM, MSc BALITBANG DEPKES RI
(1995/ 1996)
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan:
TIDAK ADA KORELASI ANTARA GANGGUAN KESEHATAN SEPERTI
SAKIT KEPALA, KELELAHAN SEPERTI SAKIT KEPALA, KELELAHAN
MENTAL, PUSING KEPALA, KEGUGURAN, SUSAH TIDUR,
BRADYCARDIA, TACHYCARDIA, INDIKASI TUMOR DAN LEUKIMIA
TERHADAP PAJANAN MEDAN LISTRIK DAN MEDAN MAGNET
TIDAK ADA KORELASI ANTARA GANGGUAN KESEHATAN SEPERTI
SAKIT KEPALA, KELELAHAN SEPERTI SAKIT KEPALA, KELELAHAN
MENTAL, PUSING KEPALA, KEGUGURAN, SUSAH TIDUR,
BRADYCARDIA, TACHYCARDIA, INDIKASI TUMOR DAN LEUKIMIA
TERHADAP PAJANAN MEDAN LISTRIK DAN MEDAN MAGNET

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-23
PENELITIAN Ir. SYARIFUDIN MAHMUDSYAH M. Eng
FAKULTAS ELEKTRO- ITS
PENELITIAN Ir. SYARIFUDIN MAHMUDSYAH M. Eng
FAKULTAS ELEKTRO- ITS
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan:
DARI HASIL PENELITIAN MENGENAI DAMPAK MEDAN
ELEKTROMAGNETIK AKIBAT PEMAKAIAN TENAGA LISTRIK
KHUSUSNYA SUTT 150 KV / SUTET 500 KV PADA DAERAH
SINGOSARI GRESIK SERTA DHARMAHUSADA INDAH SURABAYA,
DARI HASIL PENGUKURAN MEDAN ELEKTROMAGNETIK AKIBAT
SUTT / SUTET DIPEROLEH DATA BAHWA KUAT MEDAN LISTRIK
DAN KUAT MEDAN MAGNET MASIH JAUH DIBAWAH LEVEL
TOLERANSI BERDASARKAN STANDAR IRPA DAN INRC. MASALAH
YANG DIHADAPI PENDUDUK LEBIH CONDONG KEPADA MASALAH
PSIKOLOGIS DAN TUNTUNAN MENDAPATKAN GANTI RUGI.
DARI HASIL PENELITIAN MENGENAI DAMPAK MEDAN
ELEKTROMAGNETIK AKIBAT PEMAKAIAN TENAGA LISTRIK
KHUSUSNYA SUTT 150 KV / SUTET 500 KV PADA DAERAH
SINGOSARI GRESIK SERTA DHARMAHUSADA INDAH SURABAYA,
DARI HASIL PENGUKURAN MEDAN ELEKTROMAGNETIK AKIBAT
SUTT / SUTET DIPEROLEH DATA BAHWA KUAT MEDAN LISTRIK
DAN KUAT MEDAN MAGNET MASIH JAUH DIBAWAH LEVEL
TOLERANSI BERDASARKAN STANDAR IRPA DAN INRC. MASALAH
YANG DIHADAPI PENDUDUK LEBIH CONDONG KEPADA MASALAH
PSIKOLOGIS DAN TUNTUNAN MENDAPATKAN GANTI RUGI.

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-24
KERJASAMA LEMBAGA PENELITIAN MASYARAKAT ITB - FAKULTAS KEDOKTERAN UNIVERSITAS INDONESIA
(1996/ 1997)
KERJASAMA LEMBAGA PENELITIAN MASYARAKAT ITB - FAKULTAS KEDOKTERAN UNIVERSITAS INDONESIA
(1996/ 1997)
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan:
TIDAK ADA KORELASI FREKUENSI GANGGUAN KESEHATAN
MASYARAKAT YANG TERPAJAN MEDAN LISTRIK DAN MEDAN
MAGNET DARI SUTET BERHUBUNGAN DENGAN JARAK TEMPAT
TINGGAL TERHADAP JARINGAN, DAN JUGA TIDAK ADA
PENGARUH DARI BESAR DAN LAMANYA PEMAJANAN MEDAN
LISTRIK DAN MEDAN MAGNET TERHADAP DERAJAT KELAINAN
FUNGSI SISTEM TUBUH.
TIDAK ADA KORELASI FREKUENSI GANGGUAN KESEHATAN
MASYARAKAT YANG TERPAJAN MEDAN LISTRIK DAN MEDAN
MAGNET DARI SUTET BERHUBUNGAN DENGAN JARAK TEMPAT
TINGGAL TERHADAP JARINGAN, DAN JUGA TIDAK ADA
PENGARUH DARI BESAR DAN LAMANYA PEMAJANAN MEDAN
LISTRIK DAN MEDAN MAGNET TERHADAP DERAJAT KELAINAN
FUNGSI SISTEM TUBUH.

PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-25
K E S I M P U L A N K E S I M P U L A N
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Doc:Anton/09/03/ags
Catatan:
DENGAN DEMIKIAN UNTUK SEMENTARA DAPAT DISIMPULKAN
BAHWA SAMPAI SAAT INI BESARNYA MEDAN LISTRIK DAN MEDAN
MAGNET YANG BERADA DIBAWAH DAN SEKITAR SUTT / SUTET
YANG ADA DI INDONESIA BELUM MEMBAHAYAKAN BAGI
KESEHATAN PENDUDUK
DENGAN DEMIKIAN UNTUK SEMENTARA DAPAT DISIMPULKAN
BAHWA SAMPAI SAAT INI BESARNYA MEDAN LISTRIK DAN MEDAN
MAGNET YANG BERADA DIBAWAH DAN SEKITAR SUTT / SUTET
YANG ADA DI INDONESIA BELUM MEMBAHAYAKAN BAGI
KESEHATAN PENDUDUK