CLIENTS : PGN, PERTAMINA, PUSLITBANG HANKAM, LABINKAP, PETROKIMIA GRESIK, PUSRI, PUPUK KALTIM, PLN, SEMEN GRESIK, JASA MARGA, BADAK NGL, TOTAL INDONESIE, PDAM, PT SI, JATILUHUR, PERINDUTRIAN, CNOOC, KODECO, KANMETA ENG. JAPAN, PREMIER OIL, PT GARUDA IND, NURTANIO, BKI, GEOTHERMAL, MANY OTHER PRIVATE COMPANIES…………..CHEVRON.

ORGANISATION : ASEAN, ASEAN-JAPAN, ASEAN-EEC, INDOCOR, NACE, ICC, APMACA.

PAPERS : National and International

1. PESERETA KURSUS MEMAHAMI LINGKUP APLIKASI PK YANG SANGAT LUAS.

2. MEMAHAMI TUJUAN PENERAPAN PK.

3. MEMAHAMI UNTUNG RUGI DARI MASING2 SISTEM PK.

4. MEMAHAMI DASAR2 PEMILIHAN SISTEM.

5. MENGETAHUI ADA INTERFERENSI.

6. MEMAHAMI FASILITAS2 PK.

TUJUAN PENERAPAN PK

TEKNIK PROTEKSI DAPAT DITERAPKAN UNTUK MELINDUNGI LOGAM KONSTRUKSI YANG BERADA DALAM LINGKUNGAN ELEKTROLIT (TANAH, AIR, BETON).

1. BILA KRITERIA DIPENUHI, DAN PK DITERAPKAN SEJAK AWAL, STRUKTUR SECARA TEKNIS DIANGGAP IMUN DARI SERANGAN KOROSI.

1. Coating umumnya merupakan pengendalikorosi utama, tetapi coating selalumengandung cacat (holiday).

2. Penerapan PK umumnya merupakanpelengkap coating, tetapi fungsinyavital.

3. Dalam beberapa kasus PK merupakanpengendali korosi tunggal.

PK DAN COATING

PIPA :

1. Crude

2. Bbm termasuk untuk pesawat udara

3. Gas alam

4. Bahan kimia

5. Air

6. Onshore dan offshore

7. Dll.

LAS TERMIT

ANODA Mg

Proteksi katodik pipa dengan wire plastic conductive anode

TANKI

1. Air (dasar luar dan dalam)

2. Bagian dalam Tanki di atas gedung.

3. Tanki crude oil (dasar luar dan dalam)

4. Bahan Bakar Minyak

5. Tanki bahan kimia

6. Tanki ballast tank, dll

Schematic Diagram Arrangement of CP Installation for tank bottom

Ref. Cell Zn3500 mm

to AJB

≥ 5000mm

AnodeAJB : Anode Junction Box.CJB : Cathode Junction Box.

to AJB

to CJB to CJB

+ -TR

1. Tiang pancang anjungan

2. Jembatan

3. Dermaga

4. Sheet pile di pinggir laut atau kanal

5. Buoy

6. Dll.

Tiang Pancang dan sheet pile

LAS TERMITTR

JB

ANODA

Sketsa PK tiang pancang dermaga

ANJUNGAN

1. Anjungan lepas pantai

2. Anjungan darat

3. Riser

4. Dll.

STRUKTUR BANGUNAN

1. Tiang Jembatan

2. Tulangan beton

3. Tiang pancang

4. Pelataran beton

5. Dll.

Tulangan beton tanpa proteksi katodik

Struktur yang diproteksi

Anoda korban Mg, Al, Zn

PK SISTEM ANODA KORBAN

I

e

PK SISTEM ARUS TANDING

TR

Struktur yang diproteksi

Anoda :

boros, sedang, awet

UNTUNG 1 . TAK PERLU LISTRIK2. PEMASANGAN MUDAH3. TAK ADA INTERAKSI4. OVERPROTEKSI RINGAN5. COCOK UNTUK ARUS KECIL (murah)6. UNTUK DAERAH PADAT STRUKTUR7. DISTRIBUSI ARUS MERATA8. TAK PERLU PEMELIHARAAN9. CUKUP INSPEKSI RUTIN10. TAK PERLU BIAYA OPERASI

RUGI 1 . KELUARAN ARUS TERBATAS2. TAK EFEKTIF BILA RESISTIVITAS

ELEKTROLIT TINGGI3. TAK COCOK UNTUK STRUKTUR BESAR

YANG PERLU ARUS PROTEKSI BESAR.

UNTUNG 1 . COCOK UNTUK STRUKTUR BESAR2. DISAIN SESUAI DENGAN KEPERLUAN3. DAPAT UNTUK SEMUA NILAI

RESISTIVITAS LINGKUNGAN4. ARUS PROTEKSI MUDAH DIATUR5. UNTUK UMUR LEBIH DARI 20 TAHUN6. BIAYA AWAL RENDAH

RUGI 1 . KEMUNGKINAN TERJADI INTERAKSI2. TERGANTUNG SUMBER LISTRIK3. PERLU PEMELIHARAAN4. INSPEKSI RUTIN LEBIH SERING5. PERLU BIAYA OPERASI6. PERLU RECTIFIER